RAYPCB · ENGINEERING GUIDE
Castellated PCB Soldering: Paste Volume, Placement and Joint Inspection
Castellated PCB soldering joins a module's plated edge terminals to a carrier board. Reliable assembly depends on the complete interface: module terminal, carrier land, surface finish, stencil, paste, placement and thermal process. A visible side fillet is useful evidence, but it is not a complete description of every part of the connection.
This page focuses on assembly and quotation preparation. For carrier-footprint geometry and overlap, use castellated pads. Keeping these pages separate helps the engineer move from dimensional design to a controlled assembly trial.

Confirm the module and carrier requirements
Use the exact module drawing, recommended land pattern and assembly guidance. Include underside pads or other interfaces that may not be visible from the edge. The carrier construction and nearby thermal mass can also influence how the assembly behaves during soldering.
Identify any restrictions on process exposure, cleaning or rework from the module supplier. Do not assume that every castellated module can use the same profile or be hand-reworked in the same way. The applicable component information and assembly procedure control those decisions.
Review stencil apertures as part of the interface
The aperture controls the nominal paste cavity, while transfer and later reflow determine the deposited and joined result. Aperture dimensions, stencil thickness, paste and printing conditions need review together. Copying the carrier copper land directly into the paste layer is not always the appropriate design.
The tool calculates ideal rectangular aperture volume and the area ratio defined as opening area divided by aperture-wall area. It uses width, length and stencil thickness. The ratio is a geometric descriptor; the calculator does not assign a universal release-efficiency threshold or guarantee a successful print.
| Review item | What to establish |
|---|---|
| Interface | Review module terminals, carrier lands and any hidden underside connections. |
| Paste | Keep ideal cavity volume, transfer assumptions and measured deposit separate. |
| Inspection | Use criteria and methods appropriate to the complete assembled interface. |
| Quotation | Include sourcing, stencil, trial and verification responsibilities in the scope. |
Castellation aperture volume and area ratio
Castellation aperture volume and area ratio
Use the current inputs and keep the assumptions
Start with the feature or process question you actually need to resolve. Fields are blank until you enter values or deliberately load an illustrative example. Example mode remains labeled after editing, so a sample is not silently presented as verified project data. Clear the example before preparing a project-specific record.
Use the units printed beside each input. Keep the drawing revision, measurement basis and source of any allowance in your controlled project records. A field that asks for a limit expects your agreed requirement; the example is not an IPC threshold or a statement of RAYPCB capability. A numerical result should lead to a focused review, not replace it.
Changing any input invalidates the displayed result and disables its download until you calculate again. The text download contains the current inputs, results and assumptions. Nothing is uploaded, stored in analytics or automatically transferred into the Contact form. You may attach the file manually if it helps explain your enquiry; completing the worksheet is optional.
| Input | What to establish before using it |
|---|---|
| Review reference | Use a nonconfidential reference to connect this worksheet to the correct design or process revision. |
| Rectangular aperture width · mm | Use the actual stencil opening, not the copper land envelope. |
| Aperture length · mm | The ideal rectangle has no corner-radius correction. |
| Stencil thickness · mm | Area ratio uses opening area divided by aperture-wall area. |
| Equal apertures | Mixed aperture geometries require separate calculations. |
| Entered transfer efficiency · percent | Illustrative assumption only; use measured or justified data for a real comparison. |
Optional cost comparison from your own allowances
Use a quotation or a clearly labeled internal assumption for each input. Keep the quantity, construction and inspection scope the same when comparing alternatives. This uncalibrated planning model adds entered values; it contains no current market rates and does not issue a RAYPCB quotation. You can contact the team without completing it.
Entered process and inspection cost scenario
Distinguish ideal volume from measured paste
An entered transfer-efficiency percentage can illustrate how a measured or justified assumption changes estimated deposited volume. It is not supplied as a validated default. The model does not account for paste rheology, separation behavior or interactions between neighboring apertures.
If printing is a concern, measure the actual deposit using the appropriate inspection method and retain the aperture identity. A volume estimate cannot predict a final solder fillet or void distribution on its own. Use the result to compare proposals and identify what the assembly trial needs to measure.

Control placement and support
The module needs a placement relationship that preserves the intended land overlap and avoids interference. Review datum, orientation and any support or fixture requirement. A module that sits unevenly may present a different joint geometry from the ideal flat model.
The castellated-pad overlap tool can help screen a one-dimensional tolerance question, but it does not replace placement validation. Keep neighboring components and inspection access in view. A densely packed layout may limit how the joint can be observed or reworked later.
Define inspection evidence for the actual joint
Inspect the features required by the applicable assembly acceptance criteria and customer agreement. Side appearance, alignment and solder distribution can provide important observations. Hidden underside connections or other concealed features may require additional methods where relevant.
Do not turn one attractive fillet photograph into a claim that every terminal is acceptable. Keep component reference, sample identity and the relevant process state with the inspection record. If a defect appears repeatedly, separate paste deposition, placement, surface condition and thermal-process hypotheses before changing several variables at once.
Plan rework before it becomes urgent
Determine whether rework is permitted and what module or board restrictions apply. Access, thermal exposure, cleaning and post-rework inspection can all affect feasibility. An unsupported assumption that a module can simply be lifted and replaced may create avoidable damage or an unverified repair.
For production, retain the approved assembly route and any accepted exceptions. If the module or carrier revision changes, review the interface again. Similar external dimensions do not prove that the underside lands, terminal finish or thermal requirements are unchanged.
Build a comparable assembly quotation
Provide the module information, carrier files, quantity, sourcing responsibility and expected inspection scope. State whether stencil engineering, a prototype trial or additional verification is required. Include any fixed customer acceptance requirements before comparing totals.
The optional budget worksheet adds your entered allowances for recurring assembly and lot-level work. It contains no market rate and does not issue a quotation. Use the result to organize a discussion with the PCB Assembly team or contact RAYPCB directly with the actual files. A clear interface and evidence scope are more valuable than an unsupported instant price.
Review the module interface as one connected design
The module drawing, carrier footprint and assembly process describe different parts of one interface. Review them together using the exact revisions. Similar pitch or external dimensions do not establish that two modules have the same terminal geometry, underside lands or assembly restrictions.
Identify the controlling dimensional relationship before calculating a margin. Along-edge pitch, normal displacement, rotation and flatness have different effects. A one-dimensional overlap calculation can clarify one question but cannot approve the full interface. Keep the unmodeled relationships visible in the review.
Coordinate copper, permanent-mask openings and stencil apertures without assuming they share a shape. The intended soldering result depends on both geometry and process. Use measured paste and representative assembly evidence where needed rather than interpreting ideal cavity volume as guaranteed joint volume.
Plan inspection access before the enclosure or neighboring components hide the joint. Visible edge features can provide valuable evidence, while concealed connections may need another method. State what each observation demonstrates and keep the product's applicable acceptance criteria in the record.
Finally, include sourcing, stencil engineering, trial and verification responsibilities in the quotation. A prototype build can resolve open interface questions if those questions are defined beforehand. Preserve the resulting approved construction and evidence for recurring orders, and review changes rather than assuming that an unchanged module name means every relevant requirement remains the same.
Standards, source context and limits
Use the official references for their stated scope and the applicable controlled document for contractual requirements. A public scope page, product description or application note is not a complete acceptance specification. Material-supplier guidance applies to the named material and process; it is not evidence that every option is available for this board.
Agree the document revision, construction, inspection method and any exceptions with the responsible engineering and quality teams. The explanatory drawings and worksheet examples on this page are original planning aids, not factory records, qualification results or compliance certificates.