RAYPCB · ENGINEERING GUIDE
Micro-hole Technology for HDI PCBs: Formation to Metallization
Micro-hole technology for HDI PCBs is the sequence that creates a small, controlled connection opening and prepares it for reliable metallization. Hole formation is only one step. The target conductor, dielectric removal, residual material, sidewall geometry and later copper deposition all influence the finished interconnect.

Define the opening in three dimensions
State the intended depth and the top and bottom diameter basis. A laser-formed blind opening can taper, so one diameter does not describe the whole cavity. The receiving land must be located and sized for the process. A nominal hole size without a target layer or dielectric depth leaves the most important manufacturing question unanswered.
Use the tapered-hole worksheet to compare idealized geometry. It calculates a conical-frustum volume and simple depth-to-diameter ratios. It does not infer ablation quality, acceptable taper, target damage or plating coverage from those numbers.
Material and laser interaction are linked
The dielectric and copper do not respond identically to every wavelength or pulse regime. Glass reinforcement, resin system, copper surface condition and the opening strategy influence process selection. Laser equipment manufacturers describe different systems and processing routes; their machine specifications should not be copied into a board supplier's guaranteed capability table.
The dedicated PCB laser drilling page concentrates on equipment and process selection. This page follows the complete hole from its geometry definition through preparation and metallization.
Cleanliness at the receiving interface
After formation, residual resin or other contamination can prevent an adequate connection to the target copper. Cleaning and surface preparation must be compatible with the material and geometry. Inspecting only the entrance diameter cannot demonstrate that the bottom interface is ready for copper deposition. The etchback and desmear guide distinguishes residue removal from a specified resin-recession requirement.
The manufacturing review should identify how the process verifies the receiving surface and which evidence is representative. Avoid writing a generic chemical recipe into the drawing. The process owner needs a controlled method matched to the actual material system.

Example: tapered cavity versus straight cylinder
For an illustrative depth of 0.08 mm, top diameter of 0.12 mm and bottom diameter of 0.08 mm, the geometric cavity is smaller than a cylinder with the same top diameter and depth. The difference matters when explaining fill volume, but it is not a direct prediction of chemical usage or plating time.
The same geometry can be reported with different aspect-ratio conventions if one party uses the entrance diameter and another uses the bottom diameter. State the convention explicitly and compare like with like. The aspect-ratio guide develops that communication problem.
Tapered microvia geometry
Tapered microvia geometry
Use the current inputs and keep the assumptions
Start with the example to understand the units and output, then use Clear for my inputs before entering your project. Example mode stays visibly labeled even if you edit its numbers. The form begins without a result so an illustrative value cannot be mistaken for an approved requirement. Every field must have a valid value; zero is accepted only where it has a meaningful role in the particular model.
Read the input notes before calculating. They identify the physical boundary and what is excluded. Keep the same unit convention across the drawing and worksheet. Changing an input invalidates the previous result and disables its download until you calculate again. This prevents an old number from appearing to describe a revised geometry.
The result is a screening record. A negative margin or an out-of-range condition identifies a question to resolve; a positive margin is not a manufacturing approval. Use the record with the actual drawing, material and project requirement. The model does not load CAD files, inspect images or retrieve private factory data.
Download the current result if it helps the discussion. The text includes the entered inputs, result and limitations. It stays on your device until you choose to attach or share it. Contact is a separate step; this page does not automatically populate the enquiry form or upload a file. Avoid confidential identifiers if you only need an exploratory calculation.
| Input | What to establish before using it |
|---|---|
| Review reference | Use a nonconfidential reference that lets you connect this calculation to the correct drawing revision. |
| Top opening diameter · mm | Use the dimension at the entrance of the idealized cavity. This is not an equipment capability recommendation. |
| Bottom opening diameter · mm | The model accepts a narrowing or cylindrical cavity with positive bottom diameter. Re-entrant and irregular shapes need another model. |
| Cavity depth · mm | Use the local dielectric or cavity depth defined for the operation. Do not substitute total board thickness for a blind opening. |
| Number of equal cavities | Only equal ideal conical frustums are summed. Mixed geometries must be calculated separately; volume does not predict process time. |
Metallization completes the connection
The prepared cavity needs a conductive route and the specified copper structure. Conformal plating and copper filling have different objectives. Filling must be reviewed together with surface copper growth and the needs of later stacked stages or assembly pads. The blind-hole panel-plating page addresses that trade-off.
Ask which defects are checked at which stage: geometry, interface preparation, copper continuity, voids and final electrical connection do not all use the same measurement. Evidence is strongest when its location and construction are identifiable.
Send a geometry and evidence brief
Include the dielectric material, depth, target layer, required opening dimensions, land sizes and the proposed connection sequence. Note whether the hole will remain conformally plated, be filled or support another stacked stage. Include thermal and reliability requirements relevant to the finished product.
Can a smaller nominal entrance guarantee a denser reliable board? No; the target geometry and process window still matter. Is a visually open hole ready for plating? Not necessarily. Does the volume calculation establish fill quality? No. Use it to communicate the shape, then agree the manufacturing and inspection route before releasing the design.
Build an evidence chain from geometry to finished connection
Describe the feature at the point where each operation occurs. The initial opening, prepared surface, deposited copper and completed interconnect are different states. A requirement that belongs to the finished connection should not be evaluated only from an image taken before metallization. Likewise, a later electrical pass may not explain the cause of an earlier geometric or interface concern.
Use material identity and process stage when discussing capability. A quoted equipment accuracy, nominal hole diameter or general process name is not the entire manufacturing envelope. The material, local depth, copper structure, pattern density and intended subsequent operations can change the appropriate route. Ask for the construction represented by any example or qualification result rather than extrapolating from a machine brochure.
Make the measurement convention explicit. State the reference surface, axis, diameter plane or recession direction as appropriate. Use one unit system and show conversions where needed. If a result is close to a requirement, consider measurement resolution and uncertainty before drawing a conclusion. More decimal places from a calculator do not make an uncertain physical input more accurate.
Separate process control from customer acceptance. The manufacturer may monitor machine settings, chemistry or intermediate features to maintain a qualified process. The customer acceptance plan may focus on finished geometry, connection integrity and specified evidence. These records are related but not identical. A process setpoint within its control range does not automatically prove every finished feature meets the drawing.
When a defect is investigated, preserve the stage-specific evidence. Identify the sample, location, material and sequence so geometry, preparation and deposition causes can be distinguished. Changing several unrelated variables at once can make the next result harder to interpret. A useful engineering trial states what is being changed, which outcome will be observed and what constitutes a decision to proceed.
For quotation, supply the intended geometry and functional requirements before prescribing a factory recipe. Invite a process proposal where the design remains flexible. If a particular method is mandatory, explain the reason and the evidence needed to show it is suitable. The result should be a controlled route with meaningful checkpoints, not a generic sequence of manufacturing verbs or an unsupported promise that one named process guarantees reliability.
Standards, source context and limits
Use the performance and acceptance documents named in the procurement agreement, including their revisions and any applicable addenda. A design guide explains choices; a product acceptance requirement defines what must be demonstrated. Neither a reference link nor a calculator result is a certification of the board or the supplier. Where a value is contractually important, check the controlled document and agree the measurement method with the responsible parties.
Examples on this page are deliberately labeled and are not advertised RAYPCB limits. Supplier documentation is linked for the specific material or process context it explains. Equipment photographs and cross-section examples show the subject; they are not current production, inspection or qualification records for your order.