RAYPCB · ENGINEERING GUIDE

SMD vs NSMD Pads: Copper, Mask Registration and BGA Land Design

Solder-mask-defined and non-solder-mask-defined pads differ in which boundary defines the exposed solderable land. For an SMD construction, the mask overlaps the copper. For an NSMD construction, the opening is larger than the copper land. Neither label by itself proves that a footprint is suitable for a particular BGA.

The worksheet compares circular copper and mask dimensions with entered diameter tolerances and center-offset allowance. It reports the remaining radial relationship in the worst combination of those inputs. It is a geometry aid, not a solder-joint reliability model.

BGA package beside an unpopulated land field
BGA package beside an unpopulated land field. RAYPCB site archive image; illustrative context, not a current inspection or ownership record.

Understand the nominal cross-section

In an NSMD concept, the copper land sits inside a larger mask opening, leaving exposed substrate around the land edge. In an SMD concept, the smaller mask opening exposes only part of the copper land. The relationship affects the attachment interface and must be consistent with the component supplier's recommendation.

The drawing should identify the intended construction rather than merely showing two circles. A mask opening equal to the copper diameter does not offer a positive nominal separation in either direction. Manufacturing variation can then change the actual relationship locally.

Size variation and registration differ
Size variation and registration differ. Original explanatory drawing; schematic geometry, not released manufacturing data or inspection evidence.

SMD/NSMD registration envelope

RAYPCB ENGINEERING

SMD/NSMD registration envelope

Assembly Design and Package Engineering
Loading SMD/NSMD registration envelope…
Using this tool & sharing results

Use the stated units, input limits and model assumptions. Results support an engineering discussion; they do not approve a design, process or production order.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

Use the current inputs and keep the assumptions

Choose the question you want to resolve before entering numbers. The fields start blank. Load example deliberately if you want to understand the calculation, and keep that example separate from your project record. The example label remains visible after editing; reset the tool before preparing a record from your own data.

Use the displayed units and identify the source of each input. A dimension should refer to the same layer, reference plane and design revision as the other dimensions in the model. An entered limit is your review requirement, not an IPC value supplied by this website. Where a value is unknown, obtain it or preserve the question as open instead of guessing a familiar number.

Read the assumptions with the result. A negative margin is retained so a conflict remains visible. A positive margin only answers the stated mathematical question. It does not establish process capability, compliance, electrical performance or production yield. Checklist statuses are self-reported and do not imply that the underlying evidence has been inspected.

Changing a field invalidates the result and disables its download until you calculate again. The text download contains the current inputs, result and limitations. No CAD file is read, no project data is uploaded and nothing is automatically inserted into Contact. Attach the record manually if useful. You can request a review directly without using the worksheet.

InputWhat to establish before using it
Review referenceConnect this worksheet to a nonconfidential design/revision reference.
Nominal copper diameter · mmUse the actual released drawing and one dimensional reference.
Nominal mask opening diameter · mmUse the actual released drawing and one dimensional reference.
Copper diameter tolerance ± · mmDiameter tolerance, not radial error.
Mask diameter tolerance ± · mmDo not double count edge allowances already in this tolerance.
Maximum mask/copper center offset · mmMagnitude of relative center offset; circular features assumed.

Distinguish diameter tolerance from registration

A diameter tolerance changes the size of a feature. Registration describes displacement between the mask and copper centers. They are different effects and must be kept on a consistent radial or diametric basis.

For NSMD, the simplified minimum radial exposure is half the smallest opening minus half the largest copper diameter, minus the center-offset allowance. For SMD, the corresponding minimum overlap uses the smallest copper diameter and largest opening. The tool reports both relationships so a negative margin is visible rather than hidden by the chosen label.

Review itemWhat to establish
SMDMask opening smaller than copper, with reviewed overlap.
NSMDOpening larger than copper, with reviewed exposure.
ToleranceUse diameter and center-offset quantities consistently.
StencilPaste apertures remain a separate assembly decision.

Work through a nominal example

Suppose copper diameter is 0.30 mm with ±0.015 mm diameter variation. The opening is 0.40 mm with ±0.020 mm variation, and maximum center offset is 0.025 mm. The smallest opening is 0.380 mm and largest copper is 0.315 mm. Their radial difference is 0.0325 mm; subtracting offset leaves 0.0075 mm.

That small positive result is not an approval. It relies entirely on the entered variation model and ignores shape distortion and local effects not represented by circles. Ask the fabrication reviewer whether the dimensions and variation definitions match the proposed process. Do not double-count an allowance already included in a finished-feature requirement.

Ball-grid package underside close-up
Ball-grid package underside close-up. RAYPCB site archive image; illustrative context, not a current inspection or ownership record.

Keep neighboring webs in the review

An opening that works around one pad may leave little or no mask between adjacent pads. Review the whole array and the mask supplier or fabricator's applicable process constraints. Grouped openings or other changes need assembly review and cannot be inferred from a single-pad calculation.

Trace connections also matter. A narrow neck, wide copper connection or nearby via can alter the local exposed geometry. Use the DSBGA trace-neck guide for that particular family discussion, and the BGA pitch worksheet for copper routing space.

SMD/NSMD registration envelope: inputs and limits
SMD/NSMD registration envelope: inputs and limits. Original explanatory drawing; schematic geometry, not released manufacturing data or inspection evidence.

Do not confuse mask design with paste design

The permanent mask opening is not the stencil aperture. Paste reduction, windowing and stencil thickness are controlled for printing and solder attachment. Copying the mask opening directly into a stencil file can bypass the required assembly analysis.

For exposed-pad packages, see the QFN printing guide. For BGAs, consult the exact package guidance and the agreed stencil process. SMD or NSMD selection should remain traceable to the design and assembly decision, not to a generic claim that one option is always stronger.

Freeze the approved construction in the release

Review the exported copper and mask layers together, including overrides and local exceptions. Record the component, land dimensions, mask relation and accepted process interpretation. If the fabricator proposes an opening change, assess its effect before approving revised output.

For an enquiry, include an enlarged image and the actual layers rather than only a screenshot of the footprint name. State whether a change to copper is permitted or only the mask can be discussed. This makes the review specific and protects the electrical and mechanical intent of the original design.

Audit a footprint from supplier drawing to released output

Open the exact package drawing and the board instance side by side. Establish the part number, package suffix and reference orientation before comparing dimensions. A library name can be helpful, but it is not evidence that the installed footprint corresponds to the ordered component. Variants with similar names can differ in lead span, exposed pad or terminal numbering.

Compare the copper geometry first, then the mask and paste layers. Check that each layer performs its intended function and that a local override has not silently replaced the library rule. Include a trace connection or nearby via where it affects the attachment interface. Review the origin and rotation convention separately from the visible pin-one marker.

Keep dimensional tolerances on a consistent basis. Diameter variation, radial allowance, center offset and lead-position tolerance should not be combined as though they were the same quantity. A conservative review can be useful, but double counting the same process variation can also lead to an unnecessary redesign. Record the source and meaning of each allowance.

Inspect the footprint in its actual neighborhood. Adjacent bodies, inspection access, enclosure constraints and rework needs may require additional space beyond the land pattern. A good standalone footprint can still be placed in a poor manufacturing arrangement. The footprint and placement reviews should exchange their findings without merging all responsibilities into one unexplained clearance number.

When a correction is accepted, update the controlled source and determine which existing board instances are affected. Re-export the manufacturing data and inspect a representative changed feature. A corrected library does not prove that the current board was refreshed or that an older paste file was replaced.

For a review request, include the component drawing, relevant exported layers and a marked question. State whether copper, mask, paste or placement may change. This limits the review to an actionable decision and preserves the product requirements that a general footprint optimization might otherwise overlook.

Review sequence: SMD vs NSMD Pads
Review sequence: SMD vs NSMD Pads. Original explanatory drawing; schematic geometry, not released manufacturing data or inspection evidence.

Standards, source context and limits

The references below support the stated package, design or process context. Apply a component manufacturer's guidance to its named device or family and confirm the exact drawing revision. A supplier application note is not a universal manufacturing rule, and a public standards scope is not the complete controlled standard.

Agree the governing documents, revision basis, acceptance requirements and exceptions with the responsible engineering and quality teams. The official IPC revision table is useful for checking document status; it does not by itself resolve a project's contractual requirements. This page does not reproduce paid normative tables or claim certification.

Archive photographs illustrate relevant boards, components or assembly activity. They are not proof of the current equipment inventory or a completed qualification for your project. The explanatory drawings and worked examples are original teaching aids. Confirm actual process availability and the proposed inspection scope during the project review.