Planar Transformer PCB Design: Windings, Loss & Fabrication

Plan PCB windings, copper loss, layer connections and fabrication records. Compare DC resistance without confusing it with a complete magnetic design.

Original engineering guidance · References checked September 26, 2026

Compact planar magnetic component with a PCB and core
Existing site product photograph showing a compact core-and-board arrangement. No voltage, efficiency or current rating is inferred.

What makes planar transformer PCB design different?

A planar transformer PCB uses patterned copper windings arranged around a magnetic core. Its electrical behavior depends on the winding geometry, connection order, dielectric construction and core assembly together. The useful design output is therefore more than a spiral drawing: it is a coordinated winding schedule, stackup, insulation requirement, mechanical definition and verification plan.

Planar construction can fit a low-profile power stage and make winding geometry repeatable. It also couples magnetic design directly to fabrication choices. A copper-thickness change affects resistance and etching; an insulation change affects stack height and capacitance; a connection change can reverse winding polarity. Those dependencies should be resolved before ordering the first board, not discovered after a core has been bonded in place.

This page focuses on PCB windings and manufacturing handoff. For the complete power stage, including switches, connectors and thermal paths, use Power PCB design and manufacturing. For an uncoupled printed spiral used as a sensor, the PCB coil geometry guide is the closer starting point. A coil calculation alone does not design a transformer.

Start with a winding schedule and the core window

Create a table identifying every winding, its start and finish, polarity, turns, series sections and parallel branches. Add the layer or foil assigned to each section. The magnetic designer and PCB designer should be able to trace one complete winding through that table without inferring connections from similar-looking copper shapes.

A winding schedule defines series and parallel intent
Conceptual section only. The layer sequence is not an optimized magnetic or approved insulation construction.

Next compare the proposed construction with the actual core drawing. The center-leg opening, outer-leg clearances, available window height, board thickness and attachment method form one mechanical system. Include dielectric layers, coatings, adhesives and any separate winding boards where relevant. Nominal copper-layer count cannot tell you whether the assembled stack fits the window.

TI’s Designing Planar Magnetics seminar discusses how planar magnetic fields affect high-frequency winding-current distribution. Use it to frame the electromagnetic design questions. The worksheet below deliberately covers the narrower task of copper resistance and layer allocation; it does not select a core or establish an optimum winding arrangement.

Estimate winding DC resistance and copper-layer allocation

Enter the mean turn length, turns per layer, number of series layers and number of identical parallel branches for one winding. The tool reports turns per branch, occupied copper layers, approximate conductor length, ideal parallel resistance and an I²R loss baseline. It makes the connection assumptions visible so a six-turn winding cannot accidentally be described as three turns merely because two layers look alike.

RAYPCB ENGINEERING

Planar Winding Copper and Layer Worksheet

Board Engineering
Loading Planar Winding Copper and Layer Worksheet…
Using this tool & sharing results

Use the stated units, input limits and model assumptions. Results support an engineering discussion; they do not approve a design, process or production order.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

The model uses R = ρL/A with a linear temperature correction for copper. Each branch contains the entered series sections; identical branches divide the current equally. Additional lead length is added once per branch. Via barrels, connection pads, terminal contacts and unequal current sharing are excluded, so their contribution must be assessed separately.

For example, 80 mm mean turn length, three turns per layer and two series layers give six turns and 480 mm of winding trace per branch. Adding 20 mm of leads makes 500 mm. Two equal parallel branches occupy four copper layers. At 2 mm finished width and 70 µm copper, the ideal equivalent resistance at 20°C is approximately 30.8 mΩ. Raising the assumed copper temperature increases that result; it does not predict the temperature the winding will reach.

Separate DC copper loss from AC and magnetic loss

MechanismDesign questionWhat the simple worksheet omits
DC conductor resistanceHow much copper path is present?Vias, contacts and local width changes
Skin and proximity effectsHow does frequency redistribute current?Frequency-dependent winding resistance
Magnetic core lossIs the selected core appropriate for the waveform?Core material, flux excursion and temperature
Leakage inductanceHow strongly are the windings coupled?Field solution and terminal geometry
Interwinding capacitanceWhat common-mode current can flow?Dielectric and overlap field model
Thermal pathWhere does the generated heat go?Conduction, airflow and enclosure conditions
Copper resistance is one part of transformer loss
DC resistance cannot predict AC winding loss, core loss or temperature rise without additional models and conditions.

Using RMS current with DC resistance gives a useful baseline for copper dissipation. At switching frequencies it is not a complete winding-loss prediction. Increasing copper thickness may reduce DC resistance while providing less benefit than expected once current crowds near surfaces. Parallel layers can help, but their connections and field exposure affect current balance.

Interleaving primary and secondary sections changes the magnetic field distribution. It can reduce some losses or leakage while increasing overlap and capacitance, and it changes the insulation construction. Compare candidate arrangements against the converter’s objectives rather than treating maximum interleaving as universally best. Record which assumptions come from calculation, simulation and measurement.

Treat insulation as a system requirement

Specify the operating and transient voltages, insulation role, environmental conditions and applicable product requirements before assigning layer separations. A board material’s dielectric-strength figure alone does not establish an insulation system. Creepage along surfaces, clearance through air and solid insulation through the stack describe different paths and require different evidence.

The core, clips, heatsink and mounting hardware may create additional paths that do not appear in a copper-only drawing. Inspect openings and routed edges around the center leg. Include exposed terminals and the finished assembly in the insulation review. Where a safety standard applies, use the authorized document and a qualified product-safety assessment rather than an online spacing calculator as approval.

IEC 60664-1 addresses insulation coordination for equipment within its scope; the applicable end-product standard and construction still govern the design decision. This guide does not assign universal isolation distances or a certified working voltage to a planar board. Put approved requirements and their sources on the controlled drawing.

The linked base publication specifies a frequency scope up to 30 kHz. High-frequency power conversion can require additional applicable guidance, so do not apply its tables to a switching transformer merely because the working voltage appears to fit. Confirm the relevant edition, amendments, frequency conditions and end-product requirements with the responsible insulation specialist.

Make the copper geometry producible and inspectable

Define finished copper thickness and the minimum trace and gap conditions that matter electrically. Heavy copper changes the relationship between artwork and final conductor shape. Small spaces between high-current turns may require a different construction or geometry. Review the actual winding region rather than relying on a broad capability table detached from the chosen copper weight.

Layer connections deserve the same attention as the wide turns. A narrow neck, a small via group or a poorly shared terminal can dominate resistance and heating. Provide the intended current path and connection schedule so fabrication and assembly reviewers understand which features are critical. The heavy copper PCB guide covers copper-selection tradeoffs, while PCB DFM organizes the released geometry and open questions.

Planar transformer construction with a visible winding board
Existing site planar-transformer photograph. The visible construction does not establish the proposed winding schedule or insulation rating.

These retained product photographs illustrate compact core-and-board construction. They do not establish the winding schedule, isolation rating or efficiency of the proposed design. Those properties require the exact material, electrical and assembly records. A useful enquiry pairs a photograph or mechanical sketch with the drawing and winding table, rather than asking a supplier to infer internal construction from appearance.

Release a complete transformer build definition

Join electrical, mechanical and manufacturing records
A release package links the winding schedule to the actual fabricated and assembled construction.

The bare-board release should include Gerber or an agreed intelligent format, drill and route data, the layer stack, copper requirements, polarity markings and a controlled winding netlist. Make the core openings and board profile unambiguous. If separate winding boards are stacked, identify their sequence and orientation individually; a mirrored assembly can preserve continuity while reversing the intended magnetic relationship.

For assembly, add the exact core and hardware references, winding-board orientation, attachment method and permitted process conditions. Identify whether the core is supplied by the customer or sourced as part of the job. Agree how chipped cores, mechanical gaps or adhesive variation will be assessed. These are assembly questions in addition to PCB fabrication requirements.

Split the quote into the work actually requested: bare windings, populated power board, core assembly, electrical characterization or a defined production test. Prototype quantities and repeat quantities can have different setup and fixture contributions. This page does not provide an uncalibrated “transformer price” from copper dimensions because that would omit the largest design-dependent tasks.

Use a staged prototype measurement plan

Start by checking winding identity, continuity, isolation between intended separate circuits and polarity using an appropriate low-energy method. Compare measured DC resistance with a model that includes leads and connections. The measurement fixture and temperature should be recorded because they can materially affect a low-resistance result.

Then characterize the parameters the converter design needs, such as magnetizing and leakage inductance, capacitance and frequency-dependent loss, using suitable instruments and defined connection conditions. Evaluate the complete converter over its intended operating range. Thermal observations, transient behavior and efficiency are system results; they cannot be claimed from a PCB-only continuity check.

Keep design characterization separate from the production test specification. The former explores whether the construction works; the latter defines repeatable checks and limits for an approved revision. PCB Manufacturing can be approached with the fabrication package, and the Contact route can include the winding worksheet and the requested review scope. Attach those files manually; the worksheet does not upload them.

Planar transformer PCB questions

Do more copper layers always mean more turns?

No. Series sections add turns when connected with the correct polarity. Identical parallel branches mainly change the current path and resistance. The winding schedule must distinguish these connections explicitly.

Can this worksheet choose a core or predict saturation?

No. Core selection requires the converter waveform, volt-second balance, effective core area, magnetic properties and operating conditions. The worksheet addresses one winding’s approximate copper path and layer allocation only.

Is a multilayer PCB automatically an adequate isolation barrier?

No. The finished insulation construction, relevant paths, material system and end-product requirements need independent assessment. Layer count and nominal dielectric thickness are insufficient by themselves.

What should be sent before requesting a quote?

Send the winding schedule, stackup, core drawing, board data, quantities, assembly scope and test expectations. Mark unresolved items clearly so they can be reviewed before a fabrication or assembly commitment.

Bring your circuit and build requirements together

Send the board revision, construction, quantity and the circuit or manufacturing question you need reviewed. Identify unresolved requirements so the response can address them.

Send requirements for review

Optional: attach the downloaded worksheet manually. This guidance does not certify a design, approve a shipment or replace the applicable authorized standards.