{"id":24736,"date":"2023-04-13T06:12:45","date_gmt":"2023-04-13T06:12:45","guid":{"rendered":"https:\/\/www.raypcb.com\/?p=24736"},"modified":"2026-09-24T07:20:06","modified_gmt":"2026-09-24T07:20:06","slug":"conformal-coating-thickness","status":"publish","type":"post","link":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/","title":{"rendered":"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB"},"content":{"rendered":"<div class=\"ac-page ac-page--coating\"><header class=\"ac-hero\"><div class=\"ac-wrap\"><p class=\"ac-breadcrumb\"><a href=\"https:\/\/www.raypcb.com\/pcb-assembly\/\">PCB Assembly<\/a> \/ <a href=\"https:\/\/www.raypcb.com\/electronic-contract-manufacturing-services\/\">Contract Manufacturing<\/a><\/p><div class=\"ac-hero-grid\"><div><p class=\"ac-kicker\">RAYPCB \u00b7 Measurement handbook<\/p><h1>Conformal coating thickness: specify what will be measured<\/h1><p class=\"ac-lead\">Define dry film thickness, coating boundaries and measurement locations. Convert wet-film targets using volume solids and prepare an inspectable coating requirement.<\/p><div class=\"ac-actions\"><a class=\"ac-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Review a coating specification<\/a><a class=\"ac-btn ac-secondary\" href=\"#tool\">Open the worksheet<\/a><\/div><p class=\"ac-note\">Preliminary files and open process questions are welcome.<\/p><\/div><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-complex\/conformal-coating-application.webp\" width=\"350\" height=\"343\" loading=\"eager\" alt=\"Applicator positioned over an electronic assembly\"><figcaption>Original RAYPCB coating-article photograph. Coating chemistry, dry thickness and cure cannot be established from this image.<\/figcaption><\/figure><\/div><\/div><\/header><nav class=\"ac-nav\" aria-label=\"On this page\"><div class=\"ac-wrap\"><a href=\"#answer\">Key answer<\/a><a href=\"#specification\">Design reference<\/a><a href=\"#tool\">Worksheet<\/a><a href=\"#cost\">Cost &amp; scope<\/a><a href=\"#questions\">Questions<\/a><\/div><\/nav><section class=\"ac-section\" id=\"answer\"><div class=\"ac-wrap\"><div class=\"ac-prose\"><h2>Specify dry film thickness and the place it applies<\/h2><p>Conformal coating thickness usually refers to the cured protective film on an electronic assembly. A useful specification identifies the coating product, dry-film range, required coverage, keep-out regions, cure condition and measurement method. A thickness number without those details is difficult to manufacture consistently and even harder to inspect fairly.<\/p><p>Liquid wet-film thickness is a different quantity. Solvent or water leaves during drying, while curing may introduce other changes. A wet reading therefore cannot be treated as a final dry reading. Equally, a measurement on a convenient flat coupon does not automatically represent the film at a sharp lead, a board edge or a shadowed region under a component.<\/p><\/div><\/div><\/section><section class=\"ac-section\" id=\"specification\"><div class=\"ac-wrap\"><div class=\"ac-prose\"><h2>A thickness callout is part of a complete coating drawing<\/h2><div class=\"ac-table\" tabindex=\"0\" role=\"region\" aria-label=\"Assembly engineering comparison\"><table><thead><tr><th scope=\"col\">Define<\/th><th scope=\"col\">Why it matters<\/th><th scope=\"col\">Useful record<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Product and revision<\/th><td>Chemistry and processing instructions differ<\/td><td>Approved coating, thinner and data-sheet revision<\/td><\/tr><tr><th scope=\"row\">Dry-film limits<\/th><td>Both thin and excessive areas can create problems<\/td><td>Minimum\/maximum and the locations where they apply<\/td><\/tr><tr><th scope=\"row\">Coverage and keep-outs<\/th><td>Connectors, sensors and test access need explicit boundaries<\/td><td>Marked drawing for both assembly sides<\/td><\/tr><tr><th scope=\"row\">Cure state<\/th><td>A dry-looking surface may not be fully cured<\/td><td>Method, time, conditions and any required verification<\/td><\/tr><tr><th scope=\"row\">Measurement<\/th><td>Substrate and surface shape affect what can be measured<\/td><td>Instrument, witness points, calibration and uncertainty<\/td><\/tr><tr><th scope=\"row\">Rework<\/th><td>Removal and repair may expose or damage underlying materials<\/td><td>Approved removal, cleaning, recoating and inspection route<\/td><\/tr><\/tbody><\/table><\/div><p>HumiSeal&#x27;s <a href=\"https:\/\/blog.chasecorp.com\/humiseal\/conformal-coating-thickness-standards-guide\" target=\"_blank\" rel=\"noopener\">thickness and standards guide<\/a> gives 25\u201375 \u00b5m as a common dry-film range for many acrylic, urethane and silicone products and 5\u201325 \u00b5m for parylene. These are supplier-published orientation ranges, not a universal acceptance table. The current product data sheet and agreed assembly requirement determine the actual limits; some systems require a different thickness.<\/p><p>A thicker coating is not automatically a better coating. Excess film can affect cure, flexibility, stress, heat dissipation and serviceability. A thin region may fail the coverage or protection objective. The appropriate balance depends on the actual material and environment. Do not increase thickness simply to compensate for inadequate cleaning, an uncontrolled application process or an undefined qualification requirement.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-complex\/coating-measurement-map.svg\" width=\"1200\" height=\"640\" loading=\"lazy\" alt=\"Specify coverage and measurement locations\"><figcaption>A flat measurement coupon cannot by itself prove coating over sharp leads, edges or hidden regions of a populated assembly.<\/figcaption><\/figure><\/div><\/div><\/section><section class=\"ac-section\" id=\"tool\"><div class=\"ac-wrap\"><div class=\"ac-prose\"><h2>Translate a dry target into a liquid-film planning range<\/h2><p>The worksheet uses a simple volume balance: dry thickness is approximately wet thickness multiplied by volume-solids fraction. Enter the dry limits and the volume-solids content of the material as applied, including any approved dilution. Weight-percent solids is not interchangeable with volume-percent solids. If only weight data are available, obtain the appropriate product information instead of substituting the number.<\/p><p>Interactive engineering tool available on the website.<\/p><p>For an illustrative 30\u201360 \u00b5m dry target and 40% volume solids, the ideal wet-film interval is 75\u2013150 \u00b5m. A measured 100 \u00b5m wet film would correspond to an ideal 40 \u00b5m dry film under the model. This example is arithmetic, not a named coating recipe. Real deposition, flow, cure and surface geometry must be checked with dry-film measurements for the selected product.<\/p><p>The optional reading list compares measured dry-film values with your entered dry limits and reports individual out-of-window readings. It does not decide whether the board passes an acceptance standard. Your sampling plan, instrument uncertainty, allowed exceptions and decision rule remain part of the project agreement. Use labelled measurement locations in the production record even when the quick worksheet contains only numeric readings.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-complex\/coating-wet-dry-film.svg\" width=\"1200\" height=\"640\" loading=\"lazy\" alt=\"Wet thickness and dry thickness are different\"><figcaption>Ideal volume balance for a uniform liquid coating. Not applicable to vapor-deposited parylene; cure chemistry and application can change the relationship.<\/figcaption><\/figure><\/div><\/div><\/section><section class=\"ac-section\" id=\"measurement\"><div class=\"ac-wrap\"><div class=\"ac-prose\"><h2>Match the measurement method to the surface<\/h2><p>Wet-film gauges are useful process aids when the surface and coating permit them, but they may disturb the film. A measurement should not damage a finished critical region simply because it is convenient. Use an approved witness area or coupon where appropriate, and define whether the measurement occurs before material has flowed or solvent has begun to leave.<\/p><p>Dry-film methods must suit the substrate and film. A differential measurement compares coated and uncoated thickness under controlled conditions; an instrument-based method needs an appropriate measurement principle and calibration. Cross-section analysis can reveal a local film profile but is destructive and highly location-specific. Select the method with the coating supplier and inspection engineer instead of assuming any general paint gauge works on a populated PCB.<\/p><p>Fluorescence helps reveal where a compatible coating has been applied and can make certain coverage defects visible. Brightness is influenced by the material, illumination, viewing conditions and geometry. It is not, by itself, a calibrated thickness measurement. A photograph with a bright coating region should not be presented as proof that the dry film meets a numerical limit.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-complex\/coating-uv-coverage-view.webp\" width=\"1000\" height=\"586\" loading=\"lazy\" alt=\"Coating process viewed under blue illumination\"><figcaption>Original RAYPCB coating image. Visible fluorescence is useful for coverage context; it is not a quantitative film-thickness reading or a waterproof rating.<\/figcaption><\/figure><\/div><\/div><\/section><section class=\"ac-section\" id=\"locations\"><div class=\"ac-wrap\"><div class=\"ac-prose\"><h2>Inspect the difficult regions, not just the average<\/h2><p>Coating can collect at component bases and recede from sharp edges. The same assembly may contain a thick pool, a thin lead edge and an acceptable flat area. An average of selected readings can hide those differences. The drawing should identify the regions that need quantitative measurements and those assessed by a specified coverage or workmanship criterion.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-complex\/coating-thickness-window.svg\" width=\"1200\" height=\"640\" loading=\"lazy\" alt=\"Averages can hide individual thin or thick locations\"><figcaption>The worksheet compares entered readings with user-entered bounds. Sampling, gauge uncertainty, cure state and acceptance rules need a separate agreement.<\/figcaption><\/figure><p>Suppose five illustrative readings are 29, 35, 42, 48 and 61 \u00b5m against a 30\u201360 \u00b5m requirement. Their average is 43 \u00b5m, which lies inside the interval, but two individual readings are outside it. Whether those positions constitute a reject depends on the specified measurement locations and acceptance rule. The worksheet deliberately reports the outliers instead of converting the average into a reassuring pass badge.<\/p><p>Record instrument resolution and uncertainty, coupon material, surface condition and cure state. Readings near a limit may need an agreed guard band or another decision rule. Do not silently round a value into compliance. Keep the measurement plan consistent across prototype and repeat orders so apparent process changes are not caused by a new measurement method or location.<\/p><\/div><\/div><\/section><section class=\"ac-section\" id=\"process\"><div class=\"ac-wrap\"><div class=\"ac-prose\"><h2>Thickness control starts before application<\/h2><p>Cleanliness and compatibility matter before the first coat is applied. Flux residues, handling contamination and incompatible materials can affect adhesion or protection. \u201cNo-clean\u201d identifies a soldering-material\/process context; it does not automatically establish compatibility with every coating or service environment. Agree the necessary cleaning and drying route for the actual assembly and coating system.<\/p><p>Application variables include viscosity at a stated temperature, approved thinner ratio, dispense or spray settings, travel path, number of passes and time between stages. Keep-outs require a defined masking method and removal sequence. A fixture that changes the board angle can also change flow or access. Record meaningful process conditions so a qualified result can be reproduced rather than relying on a final appearance check alone.<\/p><p>Electrolube&#x27;s <a href=\"https:\/\/www.macdermidalpha.com\/sites\/default\/files\/2025-06\/Electrolube-AFA-CNC-TDS-GL-EN-04Feb2024.pdf\" target=\"_blank\" rel=\"noopener\">AFA technical data sheet<\/a> is an example of product-specific application and dilution guidance. Its instructions belong to that product, not every acrylic coating. Use the selected material&#x27;s current technical and processing documents for actual curing and handling. A broad chemistry name such as acrylic or silicone is not enough to establish all process settings.<\/p><\/div><\/div><\/section><section class=\"ac-section\" id=\"standards\"><div class=\"ac-wrap\"><div class=\"ac-prose\"><h2>Distinguish material qualification from assembly acceptance<\/h2><p>IPC-CC-830 addresses insulating-compound qualification and performance for printed wiring assemblies. IPC-A-610 addresses assembly acceptability, while applicable process requirements may also be defined by J-STD-001 and the contractual drawing. Their roles are different. A coating material&#x27;s qualification does not prove that a specific assembly has been cleaned, masked, coated and cured correctly.<\/p><p>Use the <a href=\"https:\/\/www.electronics.org\/ipc-standards\" target=\"_blank\" rel=\"noopener\">official IPC standards directory<\/a> to identify the relevant documents and current revision, then state which requirements apply to the purchase. The <a href=\"https:\/\/www.raypcb.com\/ipc-standard-for-pcb-assembly\/\">RAYPCB assembly standards guide<\/a> helps organize that conversation. Do not combine a material certificate, a generic thickness range and a class label into an unsupported claim of total compliance.<\/p><p>Conformal coating also does not automatically make a product waterproof, hermetic or suitable for a safety-critical environment. Required electrical, moisture, <a href=\"https:\/\/www.raypcb.com\/clean-circuit-board-corrosion\/\">corrosion<\/a>, temperature-cycle or other qualification evidence depends on the complete design. An application-specific evaluation should include connectors, enclosure features and uncoated areas, not only the polymer film on a flat test coupon.<\/p><\/div><\/div><\/section><section class=\"ac-section\" id=\"cost\"><div class=\"ac-wrap\"><div class=\"ac-prose\"><h2>Quote coverage, masking and inspection together<\/h2><p>Coating cost includes more than the material volume. Preparation, cleaning, masking, application, cure time, inspection, records and rework can dominate a small or complex build. Two assemblies with equal coated area can require very different effort if one has many connectors, sensitive openings or tight keep-out boundaries. Supply the marked coverage drawing when asking for a price.<\/p><p>Separate one-time programming and fixture work from recurring operations. State whether both sides are coated, how tests are sequenced, whether access points remain available and whether repaired boards need a special acceptance route. Do not assume the lowest liquid-material price gives the lowest accepted-assembly cost. A proper comparison includes the complete process and required verification.<\/p><p>For a broader manufacturing program, coordinate coating with <a href=\"https:\/\/www.raypcb.com\/electronic-contract-manufacturing-services\/\">electronic contract manufacturing<\/a>. The <a href=\"https:\/\/www.raypcb.com\/required-files-for-pcba-printed-circuit-board-assembly\/\">required PCBA files guide<\/a> covers the base release package; add coating product, coverage, dry-film limits, cure instructions, inspection plan and environmental requirements. Unresolved chemistry or thickness choices can be included as engineering questions in the enquiry.<\/p><\/div><\/div><\/section><section class=\"ac-section\" id=\"questions\"><div class=\"ac-wrap\"><div class=\"ac-prose\"><h2>Coating thickness questions<\/h2><details><summary>Is a 50 \u00b5m coating correct for every PCB?<\/summary><p>No. It can be a reasonable value within some product-specific ranges, but the coating material, environment and acceptance requirements decide the target. State the dry-film range and measurement location rather than copying a single general value.<\/p><\/details><details><summary>Can I use weight-percent solids in the wet\/dry calculation?<\/summary><p>No. The simple thickness balance requires volume fraction for the applied material. Weight data cannot be substituted without the additional information and valid conversion needed to obtain volume solids.<\/p><\/details><details><summary>Does the worksheet apply to parylene?<\/summary><p>The wet-film conversion does not. Parylene is deposited from a vapor process and needs its own thickness-control method. Numeric dry readings may still be compared with specified limits, but do not use a liquid-solids model to plan the deposition.<\/p><\/details><details><summary>Does UV fluorescence prove the correct coating thickness?<\/summary><p>No. It can support coverage inspection for a suitable material, but is not a quantitative thickness result unless a specific calibrated method establishes that relationship. Record thickness using the agreed measurement method.<\/p><\/details><details><summary>Should coating be applied before functional testing?<\/summary><p>The test and coating sequence must preserve necessary access and avoid contaminating or damaging the film. Many projects include electrical checks before coating and specified checks afterwards. Define the route for the actual assembly rather than treating either sequence as universal.<\/p><\/details><\/div><\/div><\/section><section class=\"ac-section\" id=\"project-review\"><div class=\"ac-wrap\"><div class=\"ac-enquiry\"><h2>Review a coating specification<\/h2><p>Send the drawing revision, BOM, quantity and the process question you need resolved. Include component instructions, mechanical restrictions and required inspection or test records where relevant.<\/p><div class=\"ac-actions\"><a class=\"ac-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Send your assembly requirements<\/a><a class=\"ac-btn ac-secondary\" href=\"mailto:sales@raypcb.com?subject=Conformal%20Coating%20Thickness%20review\">Open an enquiry email<\/a><\/div><p class=\"ac-note\">Tool use is optional. Attach any downloaded brief manually; Contact does not automatically receive worksheet inputs. References reviewed September 2026. Illustrations are explanatory, and photographs are not process qualification records.<\/p><\/div><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>PCB Assembly \/ Contract ManufacturingRAYPCB \u00b7 Measurement handbookConformal coating thickness: specify what will be measuredDefine dry film thickness, coating boundaries and measurement locations. Convert wet-film targets using volume solids and prepare an inspectable coating requirement.Review a coating specificationOpen the worksheetPreliminary files and open process questions&hellip;<\/p>\n","protected":false},"author":1,"featured_media":8608,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-24736","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB - RayPCB<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.raypcb.com\/conformal-coating-thickness\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB - RayPCB\" \/>\n<meta property=\"og:description\" content=\"PCB Assembly \/ Contract ManufacturingRAYPCB \u00b7 Measurement handbookConformal coating thickness: specify what will be measuredDefine dry film thickness, coating boundaries and measurement locations. Convert wet-film targets using volume solids and prepare an inspectable coating requirement.Review a coating specificationOpen the worksheetPreliminary files and open process questions&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.raypcb.com\/conformal-coating-thickness\/\" \/>\n<meta property=\"og:site_name\" content=\"RayPCB\" \/>\n<meta property=\"article:published_time\" content=\"2023-04-13T06:12:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-24T07:20:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.raypcb.com\/wp-content\/uploads\/2020\/03\/PCBA-Conformal_coating.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"RAYPCB\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"RAYPCB\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/\"},\"author\":{\"name\":\"RAYPCB\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"headline\":\"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB\",\"datePublished\":\"2023-04-13T06:12:45+00:00\",\"dateModified\":\"2026-09-24T07:20:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/\"},\"wordCount\":1585,\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/PCBA-Conformal_coating.jpg\",\"articleSection\":[\"Blogs\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/\",\"name\":\"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB - RayPCB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/PCBA-Conformal_coating.jpg\",\"datePublished\":\"2023-04-13T06:12:45+00:00\",\"dateModified\":\"2026-09-24T07:20:06+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/PCBA-Conformal_coating.jpg\",\"contentUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/PCBA-Conformal_coating.jpg\",\"width\":1920,\"height\":800,\"caption\":\"PCBA Conformal coating\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/conformal-coating-thickness\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.raypcb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/\",\"name\":\"RayPCB\",\"description\":\"PCB manufacturer and PCB assembly\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.raypcb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\",\"name\":\"RAYPCB\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"caption\":\"RAYPCB\"},\"sameAs\":[\"https:\\\/\\\/www.raypcb.com\"],\"url\":\"https:\\\/\\\/www.raypcb.com\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB - RayPCB","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/","og_locale":"en_US","og_type":"article","og_title":"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB - RayPCB","og_description":"PCB Assembly \/ Contract ManufacturingRAYPCB \u00b7 Measurement handbookConformal coating thickness: specify what will be measuredDefine dry film thickness, coating boundaries and measurement locations. Convert wet-film targets using volume solids and prepare an inspectable coating requirement.Review a coating specificationOpen the worksheetPreliminary files and open process questions&hellip;","og_url":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/","og_site_name":"RayPCB","article_published_time":"2023-04-13T06:12:45+00:00","article_modified_time":"2026-09-24T07:20:06+00:00","og_image":[{"width":1920,"height":800,"url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2020\/03\/PCBA-Conformal_coating.jpg","type":"image\/jpeg"}],"author":"RAYPCB","twitter_card":"summary_large_image","twitter_misc":{"Written by":"RAYPCB","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/#article","isPartOf":{"@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/"},"author":{"name":"RAYPCB","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"headline":"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB","datePublished":"2023-04-13T06:12:45+00:00","dateModified":"2026-09-24T07:20:06+00:00","mainEntityOfPage":{"@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/"},"wordCount":1585,"image":{"@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2020\/03\/PCBA-Conformal_coating.jpg","articleSection":["Blogs"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/","url":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/","name":"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB - RayPCB","isPartOf":{"@id":"https:\/\/www.raypcb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/#primaryimage"},"image":{"@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2020\/03\/PCBA-Conformal_coating.jpg","datePublished":"2023-04-13T06:12:45+00:00","dateModified":"2026-09-24T07:20:06+00:00","author":{"@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"breadcrumb":{"@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.raypcb.com\/conformal-coating-thickness\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/#primaryimage","url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2020\/03\/PCBA-Conformal_coating.jpg","contentUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2020\/03\/PCBA-Conformal_coating.jpg","width":1920,"height":800,"caption":"PCBA Conformal coating"},{"@type":"BreadcrumbList","@id":"https:\/\/www.raypcb.com\/conformal-coating-thickness\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.raypcb.com\/"},{"@type":"ListItem","position":2,"name":"How the Functionality of Electronic Devices is Affected by the Conformal Coating Thickness on PCB"}]},{"@type":"WebSite","@id":"https:\/\/www.raypcb.com\/#website","url":"https:\/\/www.raypcb.com\/","name":"RayPCB","description":"PCB manufacturer and PCB assembly","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.raypcb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f","name":"RAYPCB","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","caption":"RAYPCB"},"sameAs":["https:\/\/www.raypcb.com"],"url":"https:\/\/www.raypcb.com\/author\/admin\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2020\/03\/PCBA-Conformal_coating.jpg","_links":{"self":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/24736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/comments?post=24736"}],"version-history":[{"count":1,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/24736\/revisions"}],"predecessor-version":[{"id":119367,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/24736\/revisions\/119367"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media\/8608"}],"wp:attachment":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media?parent=24736"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/categories?post=24736"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/tags?post=24736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}