{"id":25359,"date":"2023-05-08T03:50:37","date_gmt":"2023-05-08T03:50:37","guid":{"rendered":"https:\/\/www.raypcb.com\/?p=25359"},"modified":"2026-09-29T08:42:04","modified_gmt":"2026-09-29T08:42:04","slug":"no-clean-flux-vs-water-soluble-flux","status":"publish","type":"post","link":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/","title":{"rendered":"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent?"},"content":{"rendered":"<div class=\"cln-page cln-page--comparison\"><header class=\"cln-hero\"><div class=\"cln-wrap\"><p class=\"cln-breadcrumb\"><a href=\"https:\/\/www.raypcb.com\/pcb-manufacturing\/\">PCB Assembly<\/a> \/ <a href=\"https:\/\/www.raypcb.com\/printed-circuit-boards-assembly-process\/\">PCB Assembly Process<\/a><\/p><div class=\"cln-hero-grid\"><div><p class=\"cln-kicker\">RAYPCB \u00b7 ENGINEERING REFERENCE<\/p><h1>No-Clean vs Water-Soluble Flux: Process and Cleaning Tradeoffs<\/h1><p class=\"cln-lead\">Compare two complete flux and cleaning routes without treating a flux as a cleaning agent.<\/p><div class=\"cln-actions\"><a class=\"cln-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Discuss your requirements<\/a><a class=\"cln-btn cln-secondary\" href=\"#tool\">Open the worksheet<\/a><\/div><p class=\"cln-note\">Original engineering guidance \u00b7 References checked September 29, 2026<\/p><\/div><figure class=\"cln-figure cln-diagram\"><a class=\"cln-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/compare-overview.svg\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/compare-overview.svg\" width=\"1200\" height=\"680\" loading=\"eager\" alt=\"Compare complete routes, not just flux labels\"><\/a><figcaption>Original engineering sequence. It is not a universal chemical recipe, an inspection report or product approval.<\/figcaption><\/figure><\/div><\/div><\/header><nav class=\"cln-nav\" aria-label=\"On this page\"><div class=\"cln-wrap\"><a href=\"#answer\">Key answer<\/a><a href=\"#reference\">Engineering reference<\/a><a href=\"#tool\">Interactive worksheet<\/a><a href=\"#questions\">Questions<\/a><\/div><\/nav><section class=\"cln-section\" id=\"answer\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>Compare the soldering and residue-management routes<\/h2><p>No-clean flux and water-soluble flux are soldering-material categories, not alternative cleaning agents. Their useful comparison includes soldering performance, the residue-management route, assembly compatibility, verification and total process scope. A material with an attractive purchase price can require equipment, handling or validation that changes the practical choice.<\/p><p>A no-clean route may retain the processed residue when the product and downstream conditions support that decision. A water-soluble route must follow the exact product&#x27;s removal instructions and demonstrate effective cleaning of the relevant locations. Neither category alone proves the reliability of an assembled board, and neither should be selected from a blanket ranking of \u201cbest flux.\u201d<\/p><p>This page compares two complete candidates. The <a href=\"https:\/\/www.raypcb.com\/no-clean-flux\/\">no-clean flux guide<\/a> owns the retention decision, while the <a href=\"https:\/\/www.raypcb.com\/how-to-clean-pcbs-after-surface-mount-soldering\/\">post-solder cleaning guide<\/a> owns production wash, rinse, drying and monitoring. Keeping those tasks separate lets the comparison remain focused on the design and process choice.<\/p><\/div><\/div><\/section><section class=\"cln-section\" id=\"reference\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>A useful comparison matrix includes the conditions<\/h2><div class=\"cln-table\" tabindex=\"0\" role=\"region\" aria-label=\"Engineering reference table\"><table><thead><tr><th scope=\"col\">Decision item<\/th><th scope=\"col\">No-clean candidate<\/th><th scope=\"col\">Water-soluble candidate<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Soldering task<\/th><td>Check the exact formulation and process<\/td><td>Check the exact formulation and process<\/td><\/tr><tr><th scope=\"row\">Residue plan<\/th><td>Retain only with applicable evidence, or qualify removal<\/td><td>Follow the product-specific removal instructions<\/td><\/tr><tr><th scope=\"row\">Assembly access<\/th><td>Hidden residues may still need evaluation<\/td><td>Cleaning and rinse must reach critical locations<\/td><\/tr><tr><th scope=\"row\">Component restrictions<\/th><td>Matter if cleaning is introduced<\/td><td>Must fit the proposed cleaning route<\/td><\/tr><tr><th scope=\"row\">Downstream surfaces<\/th><td>Verify contacts, coating and bonding interfaces<\/td><td>Verify the cleaned and dried state before the next operation<\/td><\/tr><tr><th scope=\"row\">Cost scope<\/th><td>Include validation and any required local removal<\/td><td>Include wash, rinse, drying, controls and verification<\/td><\/tr><\/tbody><\/table><\/div><p>The categories contain different formulations and intended uses. A wave-soldering flux example cannot be assumed to represent every <a href=\"https:\/\/www.raypcb.com\/solder-paste\/\">solder paste<\/a> or rework flux. Record the exact products for both candidates, including revision and supplier instructions. Otherwise, a comparison can appear precise while describing no actual materials that procurement or production can use.<\/p><p>The official <a href=\"https:\/\/www.kester.com\/products\/product\/951-soldering-flux\" target=\"_blank\" rel=\"noopener\">Kester 951 product record<\/a> identifies a no-clean example. The <a href=\"https:\/\/www.kester.com\/downloads?Command=Core_Download&amp;EntryId=38893\" target=\"_blank\" rel=\"noopener\">Kester 2331-ZX technical data sheet<\/a> describes a specific water-soluble product and its cleaning guidance. These examples demonstrate why product-specific documents matter; their conditions are not universal settings for the two categories.<\/p><figure class=\"cln-figure cln-photo\"><a class=\"cln-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/soldering-flux-reference.webp\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/soldering-flux-reference.webp\" width=\"1024\" height=\"427\" loading=\"lazy\" alt=\"Container of amber soldering material from the existing site library\"><\/a><figcaption>Existing soldering-material photograph. Its appearance does not identify a no-clean or water-soluble formulation.<\/figcaption><\/figure><\/div><\/div><\/section><section class=\"cln-section\" id=\"design\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>Let the populated assembly constrain the route<\/h2><p>Review all components and exposed materials before introducing a wash. A connector, sensor, label, adhesive or coating may impose restrictions not shared by the laminate. Low standoffs and enclosed regions can also make removal, rinsing and drying difficult even when the chemistry is compatible with the accessible surfaces.<\/p><p>For component-specific context, pSemi&#x27;s <a href=\"https:\/\/www.psemi.com\/pdf\/app_notes\/an62.pdf\" target=\"_blank\" rel=\"noopener\">AN62 assembly note<\/a> discusses cleaning considerations around low-standoff packages and material interactions. Use the applicable instructions for the actual device population. A general recommendation based on board type cannot substitute for those restrictions.<\/p><p>The electrical application also matters when residue is retained. Identify sensitive nodes, spacing, bias and environmental conditions relevant to the requirement. The comparison should preserve these constraints on both routes, rather than giving one candidate a cosmetic inspection and requiring the other to meet a more demanding electrical test.<\/p><\/div><\/div><\/section><section class=\"cln-section\" id=\"processing\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>Compare complete, repeatable process definitions<\/h2><p>For each candidate, record material handling, application, soldering, residue management and the next operation. If a no-clean route still needs local removal around contacts or coating interfaces, include that work. If a water-soluble route uses cleaning equipment, include the proposed loading, rinse and drying arrangement rather than only the chemical name.<\/p><figure class=\"cln-figure cln-photo\"><a class=\"cln-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/smt-assembly-line.webp\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/smt-assembly-line.webp\" width=\"600\" height=\"360\" loading=\"lazy\" alt=\"SMT assembly line\"><\/a><figcaption>Illustrates the named equipment or reference only; no project result, model specification or coverage claim inferred.<\/figcaption><\/figure><p>Do not treat cleaning as a guaranteed correction for poor application or an uncontrolled soldering process. The quantity and location of residue can affect cleanability. Conversely, a well-controlled soldering result does not by itself prove that a particular residue can remain in every use condition. Each route needs evidence that follows the complete sequence.<\/p><p>For a fair trial, retain comparable board revisions and inspection locations. Explain any unavoidable differences in thermal exposure or equipment. If several variables change simultaneously, the result may support the complete candidate route but may not identify which individual change caused the improvement. That distinction matters when later substitutions are proposed.<\/p><\/div><\/div><\/section><section class=\"cln-section\" id=\"tool\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>Compare declared batch allowances without inventing market prices<\/h2><p>Enter the two complete route descriptions, a shared batch quantity and currency, allocated process minutes, a common loaded hourly allowance and other batch costs. The worksheet calculates each declared batch allowance and the difference per board. It keeps the technical-evidence status alongside the arithmetic and does not choose a winner from the lower number.<\/p><p>Interactive engineering tool available on the website.<\/p><p>Use comparable scopes. If one route includes cleaning verification and the other omits equivalent retention evidence, the result is not a complete cost comparison. Likewise, equipment time and operator time should not be mixed without explaining how the loaded rate represents them. Enter zero only when a term is genuinely excluded or zero within the stated scope.<\/p><p>These are user-supplied planning allowances, not current market prices or a RAYPCB quote. Yield loss, capital, utilities, disposal, rework and validation are excluded unless you include them explicitly. The result is useful for identifying what drives an assumed difference and which missing cost records should be obtained before a purchasing decision.<\/p><\/div><\/div><\/section><section class=\"cln-section\" id=\"example\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>Keep a small numerical example separate from technical selection<\/h2><p>Suppose a fictional batch contains 100 boards. Route A uses 20 allocated minutes at a loaded allowance of 60 currency units per hour plus 10 in other batch costs. Its declared total is 30. Route B uses 40 minutes at the same rate plus 20 in other costs, for a total of 60.<\/p><figure class=\"cln-figure cln-diagram\"><a class=\"cln-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/compare-section.svg\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/compare-section.svg\" width=\"1200\" height=\"680\" loading=\"lazy\" alt=\"Illustrative allowance arithmetic, not a quotation\"><\/a><figcaption>Illustrative user-entered allowance example. It excludes any cost not explicitly included by the user.<\/figcaption><\/figure><p>The difference is 30 per batch, or 0.30 per board. That arithmetic does not show that route A is suitable for the product, nor that route B is unnecessarily expensive. It only compares the costs entered under the declared scope. If one route requires additional verification or gives different production yield, obtain that evidence and revise the comparison.<\/p><p>For a quantity change, consider whether the original allowances remain applicable. A batch setup cost and a board-by-board operation scale differently. The tool divides the entered batch difference by quantity; it does not infer equipment capacity, utilisation or a volume-discount curve. Re-enter the appropriate allowances for the scenario being discussed.<\/p><\/div><\/div><\/section><section class=\"cln-section\" id=\"validation\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>Use equivalent evidence for the product requirements<\/h2><p>Define the relevant outcome before comparing candidates. It might concern electrical behaviour under humidity and bias, coating compatibility, test-contact access or a documented cleanliness requirement. Cosmetic appearance can be part of the specification, but it should not silently replace those other tasks.<\/p><p>The <a href=\"https:\/\/www.raypcb.com\/ionic-contamination-testing\/\">ionic contamination testing guide<\/a> separates extraction-based monitoring, chemical identification and electrical reliability evidence. A single numerical result cannot answer every question about a complex assembly. Keep the specimen, method and interpretation together, especially when a whole-board result could conceal a localized issue.<\/p><p>Where the contract references IPC assembly requirements, identify the applicable documents and revisions in the review. Material classification, process evidence and finished-assembly acceptance are related but different. The <a href=\"https:\/\/www.raypcb.com\/ipc-standard-for-pcb-assembly\/\">IPC assembly standards page<\/a> provides the broader framework without converting a flux label into a compliance certificate.<\/p><\/div><\/div><\/section><section class=\"cln-section\" id=\"downstream\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>Include coating, test and repair in the comparison<\/h2><p>A route selected for the initial build may also need to support test access, protection and later rework. Residue at a probe contact or an interface can change the practical choice. Review those locations and the allowed repair materials rather than assuming that every no-clean or cleaned assembly behaves the same after production.<\/p><p>For protective materials, the <a href=\"https:\/\/www.raypcb.com\/which-is-better-for-pcbs-potting-or-conformal-coating\/\">potting versus conformal-coating guide<\/a> helps define the downstream task. Confirm the actual residue or cleaned-surface compatibility with that task. Coating a surface is not proof that earlier contamination has become irrelevant.<\/p><p>If repair uses another flux, record that exception in both the technical and cost review. The additional local cleaning, inspection or validation may be significant even when the original production route avoided a wash. A comparison that ignores common repair operations can underestimate the delivered process scope.<\/p><figure class=\"cln-figure cln-diagram\"><a class=\"cln-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/compare-release.svg\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-cleaning\/compare-release.svg\" width=\"1200\" height=\"680\" loading=\"lazy\" alt=\"A useful engineering handoff has three parts\"><\/a><figcaption>Original documentation map. Completeness of a checklist does not establish acceptance or reliability.<\/figcaption><\/figure><\/div><\/div><\/section><section class=\"cln-section\" id=\"decision\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>Document why the selected route fits this assembly<\/h2><p>The decision record should name both candidate routes, the constraints, supporting evidence and unresolved items. Identify which requirements excluded a route and which differences remain commercial preferences. This is more useful than a score that combines unrelated factors into a number without showing the underlying tradeoffs.<\/p><p>Keep the review available when the assembly changes. A new sensor, coating, flux formulation or board geometry can invalidate assumptions about access or residue retention. Change control should identify which evidence remains applicable and whether a new representative trial is needed. The earlier choice is a configuration-specific decision, not a permanent ranking of two broad flux categories.<\/p><p>For <a href=\"https:\/\/www.raypcb.com\/pcb-assembly\/\">PCB assembly<\/a>, send the board revision, permitted materials, component restrictions, downstream operations and required records. Ask for an equivalent scope when requesting alternative quotations. A route with fewer visible process steps may still require more development or verification for a particular product.<\/p><p>You can <a href=\"https:\/\/www.raypcb.com\/contact\/\">request an assembly-process comparison<\/a> with the optional worksheet attached manually. If costs are not yet known, send the technical constraints first rather than inventing rates to complete a calculator. The engineering choice and the quotation can then be developed from the information actually available.<\/p><\/div><\/div><\/section><section class=\"cln-section\" id=\"questions\"><div class=\"cln-wrap\"><div class=\"cln-prose\"><h2>Flux route comparison questions<\/h2><details><summary>Is water-soluble flux itself a cleaning agent?<\/summary><p>No. It is a soldering material whose residue-management instructions depend on the specific formulation. Cleaning uses the appropriate process and materials after soldering. Keeping those roles separate prevents a misleading product comparison.<\/p><\/details><details><summary>Is a no-clean route always cheaper?<\/summary><p>No. The result depends on the complete scope, including application, inspection, downstream compatibility, any local removal and verification. The worksheet compares only the allowances you enter and does not estimate manufacturing prices from a flux category.<\/p><\/details><details><summary>Can one route be selected only from residue appearance?<\/summary><p>Appearance can identify an observation or cosmetic requirement, but it does not establish chemical identity or electrical behaviour. Compare the evidence relevant to the product and the actual processed assembly before making a technical selection.<\/p><\/details><\/div><\/div><\/section><section class=\"cln-section\"><div class=\"cln-wrap\"><div class=\"cln-enquiry\"><h2>Bring the assembly and process requirements together<\/h2><p>Send the board revision, construction, quantity and the cleaning or residue question you need reviewed. Identify unresolved requirements so the response can address them.<\/p><a class=\"cln-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Send requirements for review<\/a><p class=\"cln-note\">Optional: attach the downloaded worksheet manually. This guidance does not certify a design, approve a shipment or replace the applicable authorized standards.<\/p><\/div><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>PCB Assembly \/ PCB Assembly ProcessRAYPCB \u00b7 ENGINEERING REFERENCENo-Clean vs Water-Soluble Flux: Process and Cleaning TradeoffsCompare two complete flux and cleaning routes without treating a flux as a cleaning agent.Discuss your requirementsOpen the worksheetOriginal engineering guidance \u00b7 References checked September 29, 2026Original engineering sequence. It&hellip;<\/p>\n","protected":false},"author":1,"featured_media":25360,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-25359","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent? - RayPCB<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent? - RayPCB\" \/>\n<meta property=\"og:description\" content=\"PCB Assembly \/ PCB Assembly ProcessRAYPCB \u00b7 ENGINEERING REFERENCENo-Clean vs Water-Soluble Flux: Process and Cleaning TradeoffsCompare two complete flux and cleaning routes without treating a flux as a cleaning agent.Discuss your requirementsOpen the worksheetOriginal engineering guidance \u00b7 References checked September 29, 2026Original engineering sequence. It&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/\" \/>\n<meta property=\"og:site_name\" content=\"RayPCB\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-08T03:50:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-29T08:42:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"520\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"RAYPCB\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"RAYPCB\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/\"},\"author\":{\"name\":\"RAYPCB\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"headline\":\"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent?\",\"datePublished\":\"2023-05-08T03:50:37+00:00\",\"dateModified\":\"2026-09-29T08:42:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/\"},\"wordCount\":2130,\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg\",\"articleSection\":[\"Blogs\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/\",\"name\":\"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent? - RayPCB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg\",\"datePublished\":\"2023-05-08T03:50:37+00:00\",\"dateModified\":\"2026-09-29T08:42:04+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg\",\"contentUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg\",\"width\":1280,\"height\":520,\"caption\":\"No-Clean Flux vs. Water Soluble Flux\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/no-clean-flux-vs-water-soluble-flux\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.raypcb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/\",\"name\":\"RayPCB\",\"description\":\"PCB manufacturer and PCB assembly\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.raypcb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\",\"name\":\"RAYPCB\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"caption\":\"RAYPCB\"},\"sameAs\":[\"https:\\\/\\\/www.raypcb.com\"],\"url\":\"https:\\\/\\\/www.raypcb.com\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent? - RayPCB","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/","og_locale":"en_US","og_type":"article","og_title":"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent? - RayPCB","og_description":"PCB Assembly \/ PCB Assembly ProcessRAYPCB \u00b7 ENGINEERING REFERENCENo-Clean vs Water-Soluble Flux: Process and Cleaning TradeoffsCompare two complete flux and cleaning routes without treating a flux as a cleaning agent.Discuss your requirementsOpen the worksheetOriginal engineering guidance \u00b7 References checked September 29, 2026Original engineering sequence. It&hellip;","og_url":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/","og_site_name":"RayPCB","article_published_time":"2023-05-08T03:50:37+00:00","article_modified_time":"2026-09-29T08:42:04+00:00","og_image":[{"width":1280,"height":520,"url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg","type":"image\/jpeg"}],"author":"RAYPCB","twitter_card":"summary_large_image","twitter_misc":{"Written by":"RAYPCB","Est. reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/#article","isPartOf":{"@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/"},"author":{"name":"RAYPCB","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"headline":"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent?","datePublished":"2023-05-08T03:50:37+00:00","dateModified":"2026-09-29T08:42:04+00:00","mainEntityOfPage":{"@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/"},"wordCount":2130,"image":{"@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg","articleSection":["Blogs"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/","url":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/","name":"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent? - RayPCB","isPartOf":{"@id":"https:\/\/www.raypcb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/#primaryimage"},"image":{"@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg","datePublished":"2023-05-08T03:50:37+00:00","dateModified":"2026-09-29T08:42:04+00:00","author":{"@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"breadcrumb":{"@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/#primaryimage","url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg","contentUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg","width":1280,"height":520,"caption":"No-Clean Flux vs. Water Soluble Flux"},{"@type":"BreadcrumbList","@id":"https:\/\/www.raypcb.com\/no-clean-flux-vs-water-soluble-flux\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.raypcb.com\/"},{"@type":"ListItem","position":2,"name":"No-Clean Flux vs. Water Soluble Flux: Which is the Best PCB Cleaning Agent?"}]},{"@type":"WebSite","@id":"https:\/\/www.raypcb.com\/#website","url":"https:\/\/www.raypcb.com\/","name":"RayPCB","description":"PCB manufacturer and PCB assembly","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.raypcb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f","name":"RAYPCB","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","caption":"RAYPCB"},"sameAs":["https:\/\/www.raypcb.com"],"url":"https:\/\/www.raypcb.com\/author\/admin\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/No-Clean-Flux-vs.-Water-Soluble-Flux.jpg","_links":{"self":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/25359","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/comments?post=25359"}],"version-history":[{"count":1,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/25359\/revisions"}],"predecessor-version":[{"id":119840,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/25359\/revisions\/119840"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media\/25360"}],"wp:attachment":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media?parent=25359"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/categories?post=25359"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/tags?post=25359"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}