{"id":25544,"date":"2023-05-15T07:32:21","date_gmt":"2023-05-15T07:32:21","guid":{"rendered":"https:\/\/www.raypcb.com\/?p=25544"},"modified":"2026-09-24T08:12:12","modified_gmt":"2026-09-24T08:12:12","slug":"bga-via-in-pad","status":"publish","type":"post","link":"https:\/\/www.raypcb.com\/bga-via-in-pad\/","title":{"rendered":"What is BGA Via in Pad ?"},"content":{"rendered":"<div class=\"sp-page sp-page--bga\"><header class=\"sp-hero\"><div class=\"sp-wrap\"><p class=\"sp-breadcrumb\"><a href=\"https:\/\/www.raypcb.com\/pcb-manufacturing\/\">PCB Manufacturing<\/a> \/ <a href=\"https:\/\/www.raypcb.com\/hdi-pcb\/\">HDI PCB<\/a><\/p><div class=\"sp-hero-grid\"><div><p class=\"sp-kicker\">RAYPCB \u00b7 Package interface \u00b7 land-pattern workshop<\/p><h1>BGA via in pad: protect the soldering surface<\/h1><p class=\"sp-lead\">Review BGA land geometry, via fill and cap, routing space and planarity. Keep board fabrication and assembly requirements aligned.<\/p><div class=\"sp-actions\"><a class=\"sp-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Review your BGA via-in-pad design<\/a><a class=\"sp-btn sp-secondary\" href=\"#tool\">Open the worksheet<\/a><\/div><p class=\"sp-note\">Preliminary files and open process questions are welcome.<\/p><\/div><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/bga-land-product-views.webp\" width=\"1024\" height=\"427\" loading=\"eager\" alt=\"Three close-up product views of dense PCB land and via patterns\"><figcaption>Existing land-pattern photographs. Surface appearance alone does not confirm via fill, cap thickness or solder-joint quality.<\/figcaption><\/figure><\/div><\/div><\/header><nav class=\"sp-nav\" aria-label=\"On this page\"><div class=\"sp-wrap\"><a href=\"#answer\">Key answer<\/a><a href=\"#interface\">Design reference<\/a><a href=\"#tool\">Worksheet<\/a><a href=\"#cost\">Cost &amp; scope<\/a><a href=\"#questions\">Questions<\/a><\/div><\/nav><section class=\"sp-section\" id=\"answer\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>What does BGA via in pad change?<\/h2><p>BGA <a href=\"https:\/\/www.raypcb.com\/via-in-pcb-pad-vip\/\">via in pad<\/a> places a via within a ball-grid-array solder land rather than beside it. This can help escape a dense package, but it moves a fabrication feature into the soldering interface. The design must address the hole treatment, copper cap where required, surface condition, land geometry and assembly process as one connected problem.<\/p><p>An open hole under a solder land can change solder distribution during reflow. Moving a conventional via into the land without reviewing its treatment is therefore not a simple routing shortcut. The right construction depends on the package, hole geometry, board process and acceptance requirements. \u201cVia in pad\u201d describes location; it does not by itself specify a filled-and-capped structure.<\/p><p>This page focuses on the BGA package interface and its geometry. The broader <a href=\"https:\/\/www.raypcb.com\/resources\/hdi-via-in-pad\/\">HDI via-in-pad release guide<\/a> owns the general fill, cap and fabrication-handoff checklist. Use both when the design needs a clear agreement between PCB fabrication and <a href=\"https:\/\/www.raypcb.com\/bga-manufacturing-process\/\">BGA assembly<\/a>.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"interface\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Treat the pad as a soldering surface<\/h2><p>Begin with the exact package drawing and land-pattern guidance. Confirm pitch, land diameter or shape, solder-mask strategy and the relevant tolerances. A generic pitch-based rule cannot capture every package or board process. Check that the CAD footprint and the assembly drawing refer to the same package variant.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/bga-via-in-pad-interface.svg\" width=\"1100\" height=\"640\" loading=\"lazy\" alt=\"Via-in-pad joins fabrication to the soldering interface\"><figcaption>A fill-and-cap construction creates a defined soldering surface over the hole. Exact treatment, cap geometry and planarity belong to the agreed fabrication specification.<\/figcaption><\/figure><p>The via treatment should preserve the intended soldering surface. Specify the finished geometry and acceptance requirement rather than assuming that a named process guarantees a perfectly flat pad. Review recesses, protrusions, copper cap and surface finish using the applicable construction and inspection method. The assembled solder joint has its own acceptance questions that cannot be answered solely by a bare-board photograph.<\/p><p>When the via also serves a thermal or current path, document that task separately. A nonconductive fill does not remove the conductive plated barrel, but it should not be assigned the properties of a solid copper-filled structure. Thermal performance depends on the complete geometry and heat path. Avoid changing fill technology just because two structures share the same marketing label.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"tool\"><div class=\"sp-wrap sp-lab\"><h2>Screen land geometry and one routing channel<\/h2><div class=\"sp-prose\"><p>The worksheet evaluates circular lands, a maximum hole diameter, radial registration allowance and a straight copper channel. It uses minimum land diameter for the conservative annular-width calculation and maximum land diameter for the minimum pad-to-pad gap. These opposite extremes matter: a nominal-only calculation can hide either a weak landing or inadequate routing space.<\/p><p>Interactive engineering tool available on the website.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/bga-routing-channel.svg\" width=\"1100\" height=\"640\" loading=\"lazy\" alt=\"Count copper space using the worst geometry\"><figcaption>The ideal straight-channel count includes clearance to both pads and between tracks. It does not approve complete BGA escape routing.<\/figcaption><\/figure><p>For the illustrative 0.8 mm pitch, 0.40\u20130.44 mm lands, 0.15 mm maximum hole and 0.03 mm radial offset, the conservative annular width is 0.095 mm. The minimum gap is 0.36 mm. One 0.10 mm track with 0.10 mm clearance on both sides needs 0.30 mm, while two such tracks need 0.50 mm. Only one fits the simplified channel.<\/p><p>That result is not a routing approval or an <a href=\"https:\/\/www.raypcb.com\/ipc-standards\/\">IPC<\/a> acceptance result. Real escape routing includes turns, adjacent vias, mask registration, layer transitions and fabrication variation. If the count is zero, another layer or fanout strategy may still work. If the count is positive, the complete layout can still fail elsewhere. Use the result to identify the next design question, not to approve the board automatically.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"treatment\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Tented, plugged, filled and capped are different instructions<\/h2><p>Use precise treatment language. A mask tent covers an opening; it should not be assumed to create the same solderable land as a filled-and-capped construction. A plug, a full fill and a copper cap describe different features. The fabrication drawing must identify which holes receive which treatment and what finished condition is required on each face.<\/p><p>The public <a href=\"https:\/\/www.ipc.org\/TOC\/IPC-4761.pdf\" target=\"_blank\" rel=\"noopener\">IPC-4761 contents and introductory extract<\/a> distinguishes several via-protection types, including filled-and-capped Type VII. It is a useful terminology reference, not the full normative text or a source for invented cap-thickness and planarity limits. Agree the applicable document revision and detailed drawing requirements for the actual order.<\/p><div class=\"sp-table\" tabindex=\"0\" role=\"region\" aria-label=\"PCB process engineering comparison\"><table><thead><tr><th scope=\"col\">Term in the enquiry<\/th><th scope=\"col\">Clarification needed<\/th><th scope=\"col\">Assembly implication<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Via in pad<\/th><td>Location of hole relative to land<\/td><td>Does not define treatment by itself<\/td><\/tr><tr><th scope=\"row\">Filled via<\/th><td>Fill material and completeness requirement<\/td><td>Surface condition still needs definition<\/td><\/tr><tr><th scope=\"row\">Filled and capped<\/th><td>Cap construction and finished surface requirement<\/td><td>Can establish a specified soldering surface<\/td><\/tr><tr><th scope=\"row\">Copper-filled <a href=\"https:\/\/www.raypcb.com\/microvia-pcb-design-and-cost-consideration\/\">microvia<\/a><\/th><td>Geometry and qualified copper-fill process<\/td><td>Different structure from a resin-filled through via<\/td><\/tr><tr><th scope=\"row\">Tented via<\/th><td>Mask coverage and intended location<\/td><td>Not a blanket substitute beneath a BGA land<\/td><\/tr><\/tbody><\/table><\/div><p>Provide an identified hole list or drill map, not a general instruction that every via in the design must receive the same treatment. Unnecessary fill or cap requirements can affect cost and process complexity without helping the BGA interface.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"escape\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Choose the fanout with the stackup<\/h2><p>Compare an offset via, a dog-bone escape, a via-in-pad route and an appropriate blind connection against the actual package and routing need. The useful comparison includes trace\/space capability, reference continuity, signal layer assignment and manufacturing sequence. A smaller feature is not automatically the best solution if it introduces an avoidable process risk or difficult inspection requirement.<\/p><p><a href=\"https:\/\/www.ti.com\/lit\/an\/spraa99c\/spraa99c.pdf\" target=\"_blank\" rel=\"noopener\">TI\u2019s nFBGA packaging application report<\/a> discusses land areas, conductor spacing and routing techniques for its packaging context. Use it as a technical reference alongside the exact device documentation, rather than copying a dimensional recommendation into every BGA footprint.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/fine-pitch-board-product.webp\" width=\"900\" height=\"540\" loading=\"lazy\" alt=\"PCB product showing fine-pitch component escape regions\"><figcaption>Existing RAYPCB HDI product photograph used as routing context; the exterior does not prove a particular internal via construction.<\/figcaption><\/figure><p>If the escape strategy depends on a <a href=\"https:\/\/www.raypcb.com\/blind-vias\/\">blind-via construction<\/a>, settle the physical layer span and drilling method before detailed routing spreads across the board. The <a href=\"https:\/\/www.raypcb.com\/hdi-pcb\/\">HDI PCB hub<\/a> connects those stackup and manufacturing decisions. Via-in-pad is a placement decision; blind or buried describes physical access in the finished board. These descriptions can apply to the same feature without meaning the same thing.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"handoff\"><div class=\"sp-wrap sp-lab\"><h2>Give fabrication and assembly the same interface definition<\/h2><div class=\"sp-prose\"><p>The fabrication team needs the hole map, treatment, cap and finished-pad requirements. The assembly team needs the land pattern, mask openings, paste apertures, package information and expected board condition. Both teams must know when a change affects the soldering surface. A revised fill or cap process should not arrive as an undocumented substitution after the stencil is already released.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/bga-via-in-pad-handoff.svg\" width=\"1100\" height=\"640\" loading=\"lazy\" alt=\"Keep package, board and assembly revisions together\"><figcaption>Via-in-pad decisions are exchanged between the package designer, PCB fabricator and assembler. Release records need to describe the same physical interface.<\/figcaption><\/figure><p>Review paste volume and aperture strategy with the actual package and pad condition. A solder joint over a treated via should not be assumed equivalent to every ordinary land without checking the relevant geometry and process. Likewise, a surface-finish change can affect the assembly route and needs review beyond the bare-board price.<\/p><p>Keep the package, footprint, PCB artwork, via-treatment drawing and stencil revisions together. If the designer changes pad size to improve routing, the assembly process may need to change too. If the fabricator changes a hole or cap detail, recheck the land and clearance assumptions. This handoff discipline can prevent a locally reasonable change from creating a downstream assembly problem.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"inspection\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Separate hidden-board evidence from hidden-joint evidence<\/h2><p>Bare-board inspection can address treatment completeness, cap geometry, surface condition and applicable interconnect requirements using the agreed methods. The assembled BGA introduces another hidden structure: the solder joint. A single inspection method should not be claimed to prove both every buried feature and every solder connection without a defined scope.<\/p><p>Use <a href=\"https:\/\/www.raypcb.com\/pcb-x-ray-inspection\/\">PCB X-ray inspection<\/a> to understand the assembled-joint review in context. X-ray interpretation, viewing conditions and acceptance criteria matter; an image is not automatically a verdict. Electrical tests can establish specified connectivity or function, but passing a functional test does not independently measure cap thickness or qualify a hidden fabrication interface.<\/p><p>For an engineering trial, identify representative features and the evidence that will be reviewed before a repeat order. Record whether a section, measurement, image or test belongs to the bare board or assembled product. A useful acceptance plan states the requirement, method and sample location instead of collecting attractive images with no decision attached.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"cost\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>What makes via-in-pad cost more or less demanding?<\/h2><p>The process scope can include filling, curing where applicable, planarization, copper capping, additional imaging or plating steps and inspection. The hole sizes, density, distribution, materials and required finished surface affect the practical route. A board with a few selectively treated holes is a different request from a board that requires the treatment across a large dense array.<\/p><p>Compare the whole design alternative. Avoided routing layers, a different package escape or a changed board size can matter more than the isolated via-treatment charge. Conversely, an aggressive construction can add development and qualification effort. A universal percentage surcharge is not a reliable substitute for two quotations based on controlled alternative drawings.<\/p><p>Interactive engineering tool available on the website.<\/p><p>The budget brief separates per-board scope, setup and verification allowances. It uses only your entered amounts and source. Leave costs blank for a technical enquiry. State whether the allowance includes the whole PCB, only via treatment, or assembly as well; otherwise the same fabrication scope can be counted twice.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"release\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Prepare a BGA interface review package<\/h2><p>Send the exact device and package drawing, PCB revision, footprint, stackup, via map, treatment detail, finished-pad requirements and quantities. Include the proposed assembly route and any required evidence. Mark whether dimensions refer to drilled holes, finished holes or land copper after processing. Unlabeled dimensions are a frequent source of an apparently small but important misunderstanding.<\/p><p>If the design is still being routed, identify the specific bottleneck: no escape channel, unacceptable layer count, a thermal connection or a solder-surface concern. That makes it possible to compare alternatives before a costly detail is locked. The <a href=\"https:\/\/www.raypcb.com\/pcb-manufacturing\/\">PCB manufacturing overview<\/a> provides the broader production route, while this page keeps the BGA land interface explicit.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"questions\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>BGA via-in-pad questions before release<\/h2><details><summary>Does every via inside a BGA land need the same fill process?<\/summary><p>No universal process can be selected from location alone. Hole geometry, package needs, fabrication route and finished surface determine the treatment. Specify and review the exact construction instead of assuming all via-in-pad features are interchangeable.<\/p><\/details><details><summary>Does the routing worksheet select the correct pad size?<\/summary><p>No. It evaluates dimensions you supply. The device documentation and agreed fabrication and assembly requirements establish the pad geometry. The worksheet can expose a conflict but cannot override a package requirement.<\/p><\/details><details><summary>Can a tented via replace a filled-and-capped via?<\/summary><p>Do not make that substitution without engineering review. The resulting surface and solder behavior can differ. A drawing that requires a specific treatment should not be changed merely because another treatment is cheaper or easier.<\/p><\/details><details><summary>Is a passed electrical test proof of via-in-pad quality?<\/summary><p>It proves only what the test is designed to evaluate at that time. Fill, cap, planarity, interconnect reliability and assembled-joint quality may require additional evidence under the applicable acceptance and qualification plan.<\/p><\/details><\/div><\/div><\/section><section class=\"sp-section\" id=\"project-review\"><div class=\"sp-wrap\"><div class=\"sp-enquiry\"><h2>Review your BGA via-in-pad design<\/h2><p>Send the fabrication revision, stackup, quantity and the specific process question. Include connector or package requirements, mechanical drawings and the inspection evidence you need.<\/p><div class=\"sp-actions\"><a class=\"sp-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Send your manufacturing requirements<\/a><a class=\"sp-btn sp-secondary\" href=\"mailto:sales@raypcb.com?subject=BGA%20Via%20in%20Pad%20review\">Open an enquiry email<\/a><\/div><p class=\"sp-note\">Tool use is optional. Attach any downloaded brief manually; Contact does not automatically receive worksheet inputs. References reviewed September 2026. Illustrations are explanatory, and photographs are not process qualification records.<\/p><\/div><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>PCB Manufacturing \/ HDI PCBRAYPCB \u00b7 Package interface \u00b7 land-pattern workshopBGA via in pad: protect the soldering surfaceReview BGA land geometry, via fill and cap, routing space and planarity. Keep board fabrication and assembly requirements aligned.Review your BGA via-in-pad designOpen the worksheetPreliminary files and open&hellip;<\/p>\n","protected":false},"author":1,"featured_media":25545,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-25544","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What is BGA Via in Pad ? - RayPCB<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.raypcb.com\/bga-via-in-pad\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is BGA Via in Pad ? - RayPCB\" \/>\n<meta property=\"og:description\" content=\"PCB Manufacturing \/ HDI PCBRAYPCB \u00b7 Package interface \u00b7 land-pattern workshopBGA via in pad: protect the soldering surfaceReview BGA land geometry, via fill and cap, routing space and planarity. Keep board fabrication and assembly requirements aligned.Review your BGA via-in-pad designOpen the worksheetPreliminary files and open&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.raypcb.com\/bga-via-in-pad\/\" \/>\n<meta property=\"og:site_name\" content=\"RayPCB\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-15T07:32:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-24T08:12:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/bga-via-in-pad.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"416\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"RAYPCB\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"RAYPCB\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/\"},\"author\":{\"name\":\"RAYPCB\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"headline\":\"What is BGA Via in Pad ?\",\"datePublished\":\"2023-05-15T07:32:21+00:00\",\"dateModified\":\"2026-09-24T08:12:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/\"},\"wordCount\":1541,\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/bga-via-in-pad.jpg\",\"articleSection\":[\"Blogs\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/\",\"name\":\"What is BGA Via in Pad ? - RayPCB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/bga-via-in-pad.jpg\",\"datePublished\":\"2023-05-15T07:32:21+00:00\",\"dateModified\":\"2026-09-24T08:12:12+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/bga-via-in-pad.jpg\",\"contentUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/bga-via-in-pad.jpg\",\"width\":1000,\"height\":416,\"caption\":\"bga via in pad\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bga-via-in-pad\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.raypcb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is BGA Via in Pad ?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/\",\"name\":\"RayPCB\",\"description\":\"PCB manufacturer and PCB assembly\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.raypcb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\",\"name\":\"RAYPCB\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"caption\":\"RAYPCB\"},\"sameAs\":[\"https:\\\/\\\/www.raypcb.com\"],\"url\":\"https:\\\/\\\/www.raypcb.com\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is BGA Via in Pad ? - RayPCB","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.raypcb.com\/bga-via-in-pad\/","og_locale":"en_US","og_type":"article","og_title":"What is BGA Via in Pad ? - RayPCB","og_description":"PCB Manufacturing \/ HDI PCBRAYPCB \u00b7 Package interface \u00b7 land-pattern workshopBGA via in pad: protect the soldering surfaceReview BGA land geometry, via fill and cap, routing space and planarity. Keep board fabrication and assembly requirements aligned.Review your BGA via-in-pad designOpen the worksheetPreliminary files and open&hellip;","og_url":"https:\/\/www.raypcb.com\/bga-via-in-pad\/","og_site_name":"RayPCB","article_published_time":"2023-05-15T07:32:21+00:00","article_modified_time":"2026-09-24T08:12:12+00:00","og_image":[{"width":1000,"height":416,"url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/bga-via-in-pad.jpg","type":"image\/jpeg"}],"author":"RAYPCB","twitter_card":"summary_large_image","twitter_misc":{"Written by":"RAYPCB","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/#article","isPartOf":{"@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/"},"author":{"name":"RAYPCB","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"headline":"What is BGA Via in Pad ?","datePublished":"2023-05-15T07:32:21+00:00","dateModified":"2026-09-24T08:12:12+00:00","mainEntityOfPage":{"@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/"},"wordCount":1541,"image":{"@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/bga-via-in-pad.jpg","articleSection":["Blogs"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/","url":"https:\/\/www.raypcb.com\/bga-via-in-pad\/","name":"What is BGA Via in Pad ? - RayPCB","isPartOf":{"@id":"https:\/\/www.raypcb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/#primaryimage"},"image":{"@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/bga-via-in-pad.jpg","datePublished":"2023-05-15T07:32:21+00:00","dateModified":"2026-09-24T08:12:12+00:00","author":{"@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"breadcrumb":{"@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.raypcb.com\/bga-via-in-pad\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/#primaryimage","url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/bga-via-in-pad.jpg","contentUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/bga-via-in-pad.jpg","width":1000,"height":416,"caption":"bga via in pad"},{"@type":"BreadcrumbList","@id":"https:\/\/www.raypcb.com\/bga-via-in-pad\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.raypcb.com\/"},{"@type":"ListItem","position":2,"name":"What is BGA Via in Pad ?"}]},{"@type":"WebSite","@id":"https:\/\/www.raypcb.com\/#website","url":"https:\/\/www.raypcb.com\/","name":"RayPCB","description":"PCB manufacturer and PCB assembly","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.raypcb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f","name":"RAYPCB","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","caption":"RAYPCB"},"sameAs":["https:\/\/www.raypcb.com"],"url":"https:\/\/www.raypcb.com\/author\/admin\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2023\/05\/bga-via-in-pad.jpg","_links":{"self":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/25544","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/comments?post=25544"}],"version-history":[{"count":1,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/25544\/revisions"}],"predecessor-version":[{"id":119387,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/25544\/revisions\/119387"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media\/25545"}],"wp:attachment":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media?parent=25544"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/categories?post=25544"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/tags?post=25544"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}