{"id":28972,"date":"2023-11-24T05:46:08","date_gmt":"2023-11-24T05:46:08","guid":{"rendered":"https:\/\/www.raypcb.com\/?p=28972"},"modified":"2026-10-10T03:40:12","modified_gmt":"2026-10-10T03:40:12","slug":"pcb-fr4-material","status":"publish","type":"post","link":"https:\/\/www.raypcb.com\/pcb-fr4-material\/","title":{"rendered":"FR-1, FR-2, FR-3, FR-4 and FR-5: Material Differences and Selection"},"content":{"rendered":"\n<style> .ray-day4{font:17px\/1.72 Arial,Helvetica,sans-serif;color:#17394b;background:#fff;max-width:980px;margin:0 auto;overflow-wrap:anywhere}.ray-day4 *{box-sizing:border-box}.ray-day4 h1{font-size:clamp(30px,4vw,45px);line-height:1.17;color:#123448;margin:10px 0 22px}.ray-day4 h2{font-size:29px;line-height:1.3;color:#005f87;margin:0 0 16px}.ray-day4 h3{font-size:22px;line-height:1.35;color:#17394b}.ray-day4 p{margin:0 0 20px}.ray-day4 section{margin:38px 0;scroll-margin-top:155px}.ray-day4 header{border-bottom:3px solid #006b94;padding:16px 0 24px}.ray-day4 .eyebrow{font-size:14px;letter-spacing:.06em;font-weight:700;color:#52707d}.ray-day4 .answer{font-size:20px;line-height:1.55}.ray-day4 a{color:#00658d;text-decoration:underline;text-underline-offset:3px}.ray-day4 nav{padding:16px 20px;background:#edf4f7;border-left:4px solid #006b94}.ray-day4 nav a{display:inline-block;margin:4px 16px 4px 0}.ray-day4 figure{margin:28px 0}.ray-day4 figure svg{display:block;width:100%;height:auto;aspect-ratio:17\/10;max-width:680px;margin:auto}.ray-day4 figcaption{font-size:14px;line-height:1.5;color:#506b7a;margin:12px 0}.ray-day4 .table-wrap{overflow-x:auto;border:1px solid #c4d5df;margin:20px 0}.ray-day4 table{border-collapse:collapse;width:100%;font-size:16px;margin:0}.ray-day4 th{background:#17394b!important;color:#fff!important;text-align:left}.ray-day4 td,.ray-day4 th{padding:13px;border:1px solid #c4d5df;vertical-align:top}.ray-day4 tr:nth-child(even) td{background:#f2f7f9}.ray-day4 .note{padding:20px;border-left:4px solid #b9550b;background:#fff5ea}.ray-day4 details{border:1px solid #adc5d2;margin:14px 0;padding:16px;background:#f5f9fb}.ray-day4 summary{font-weight:700;color:#16445a;cursor:pointer}.ray-day4 details p{margin:16px 0 0}.ray-day4 fieldset{border:1px solid #88a9b9;padding:20px;margin:20px 0}.ray-day4 legend{font-size:21px;font-weight:700;padding:0 6px;max-width:100%}.ray-day4 label{display:flex;gap:12px;align-items:flex-start;padding:11px 0;cursor:pointer}.ray-day4 label input{width:20px;height:20px;min-width:20px;margin:5px 0 0;accent-color:#006b94}.ray-day4 fieldset p{margin:0 0 8px}.ray-day4 label:has(input:checked){color:#216445}.ray-day4 .cta{display:inline-flex;justify-content:center;align-items:center;min-height:48px;padding:12px 22px;background:#b9550b;color:#fff!important;text-decoration:none;font-weight:700;border:2px solid #b9550b;border-radius:4px}.ray-day4 .cta:hover{background:#914009}.ray-day4 a:focus-visible,.ray-day4 summary:focus-visible,.ray-day4 input:focus-visible{outline:3px solid #db820c;outline-offset:4px}.ray-day4 .equation{font:700 20px\/1.6 Arial;background:#edf4f7;padding:17px}.ray-day4 ol,.ray-day4 ul{padding-left:26px}.ray-day4 li{margin:10px 0}.ray-day4 .sources{font-size:15px;border-top:1px solid #c4d5df;padding-top:24px}@media(max-width:600px){.ray-day4{font-size:17px}.ray-day4 h2{font-size:26px}.ray-day4 header{padding-top:8px}.ray-day4 section{margin:30px 0}.ray-day4 th,.ray-day4 td{padding:9px;font-size:15px;min-width:108px}.ray-day4 .cta{width:100%}.ray-day4 nav{padding:12px}.ray-day4 fieldset{padding:14px}.ray-day4 .answer{font-size:19px}}@media print{.ray-day4 details{display:block}.ray-day4 a{color:#17394b}.ray-day4 section{break-inside:auto}.ray-day4 figure,.ray-day4 tr{break-inside:avoid}} .ray-day4{max-width:960px}.ray-day4 .cta{background:#ff7900;color:#102f40!important;border-color:#ff7900}.ray-day4 .cta:hover{background:#eb6b00}.ray-day4 .table-wrap:focus-visible{outline:3px solid #b9550b}.ray-day4 .material header{border-color:#54806c} body.postid-28972 section.elementor-element-6ddaffa{display:none}<\/style><article class=\"ray-day4\" id=\"ray-day4-u004\" data-version=\"2026.10.10-editorial-day004-r1\"><header><p class=\"eyebrow\"><a href=\"https:\/\/www.raypcb.com\/\">RAYPCB<\/a> \u00b7 <a href=\"https:\/\/www.raypcb.com\/11-types-of-pcb-circuit-board-material-specification\/\">PCB MATERIAL<\/a> SELECTION<\/p><h1>FR-1, FR-2, FR-3, FR-4 and FR-5: Material Differences and Selection<\/h1><p class=\"answer\">FR-1 and FR-2 are paper-reinforced phenolic laminates; FR-3 uses paper with <a href=\"https:\/\/www.raypcb.com\/epoxy-resin-used-for-ccl-in-pcb-and-its-development-trend\/\">epoxy resin<\/a>. FR-4 and FR-5 use woven glass with epoxy resin. These grade names describe material families. They do not create a universal ladder of signal performance, flame resistance or allowable operating temperature.<\/p><p>Use this comparison to choose the questions for a material review, then specify an actual copper-clad laminate and construction. A drawing that says only \u201cFR4\u201d usually leaves important purchasing and manufacturing decisions unresolved.<\/p><\/header>\n<nav aria-label=\"Article sections\"><a href=\"#fr-compare\">Family comparison<\/a><a href=\"#fr-thermal\">Thermal properties<\/a><a href=\"#fr-electrical\">Electrical requirements<\/a><a href=\"#fr-scenarios\">Selection examples<\/a><a href=\"#fr-purchase\">Purchase specification<\/a><\/nav>\n<section id=\"fr-compare\"><h2>Compare the reinforcement and resin first<\/h2><div class=\"table-wrap\" role=\"region\" aria-label=\"FR laminate family comparison\" tabindex=\"0\"><table><thead><tr><th>Family<\/th><th>Reinforcement and resin<\/th><th>Practical selection question<\/th><\/tr><\/thead><tbody><tr><td>FR-1<\/td><td>Paper and flame-retardant phenolic resin<\/td><td>Does the exact copper-clad grade support the intended punching, soldering and environment?<\/td><\/tr><tr><td>FR-2<\/td><td>Paper and flame-retardant phenolic resin<\/td><td>Which processing and property requirements distinguish the offered grade from FR-1?<\/td><\/tr><tr><td>FR-3<\/td><td>Paper and flame-retardant epoxy resin<\/td><td>Is a suitable copper-clad product available and qualified for this board?<\/td><\/tr><tr><td>FR-4<\/td><td>Woven glass and flame-retardant epoxy resin<\/td><td>Which laminate\/prepreg system meets the stackup, thermal and electrical requirements?<\/td><\/tr><tr><td>FR-5<\/td><td>Woven glass and flame-retardant epoxy resin, with elevated-temperature grade requirements<\/td><td>Is FR-5 specifically required, or does a qualified high-Tg FR-4 product meet the application?<\/td><\/tr><\/tbody><\/table><\/div><p>The paper-family descriptions are consistent with <a href=\"https:\/\/www.lamitex.com\/blog\/lamitex-r-nema-grade-fr-1-fr-2-fr-3\">Lamitex&#8217;s NEMA FR-1, FR-2 and FR-3 material guidance<\/a>. That source discusses industrial insulating laminates; it should not be interpreted as proof that every named grade is available as a PCB-qualified copper-clad sheet. In particular, <strong>FR-3 is not a woven-glass epoxy grade<\/strong>.<\/p><p>FR-1 and FR-2 should not be distinguished by an invented universal Tg boundary or a simple \u201cgood versus better\u201d label. Their precise grade requirements and offered products matter. For a board already qualified on a particular paper laminate, inspect the existing drawing, supplier designation and assembly history before proposing a replacement.<\/p><figure><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"680\" height=\"400\" viewBox=\"0 0 680 400\" role=\"img\" aria-labelledby=\"d4-fr-families-title d4-fr-families-desc\"><title id=\"d4-fr-families-title\">Two reinforcement groups<\/title><desc id=\"d4-fr-families-desc\">FR-1, FR-2 and FR-3 use paper; FR-4 and FR-5 use woven glass. The resin and grade requirements must also be specified.<\/desc><rect width=\"680\" height=\"400\" fill=\"#f5f9fb\"\/><text x=\"24\" y=\"38\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"700\">Two reinforcement groups<\/text><rect x=\"25\" y=\"90\" width=\"300\" height=\"227\" rx=\"5\" fill=\"#fff2e4\" stroke=\"#b55c0c\" stroke-width=\"2\"\/><text x=\"45\" y=\"132\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"29\" fill=\"#17394b\" font-weight=\"700\">PAPER<\/text><text x=\"45\" y=\"187\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"400\">FR-1 \u00b7 phenolic<\/text><text x=\"45\" y=\"229\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"400\">FR-2 \u00b7 phenolic<\/text><text x=\"45\" y=\"272\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"400\">FR-3 \u00b7 epoxy<\/text><rect x=\"355\" y=\"90\" width=\"300\" height=\"227\" rx=\"5\" fill=\"#e4f0e8\" stroke=\"#54806c\" stroke-width=\"2\"\/><text x=\"375\" y=\"132\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"27\" fill=\"#17394b\" font-weight=\"700\">WOVEN GLASS<\/text><text x=\"375\" y=\"199\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"400\">FR-4 \u00b7 epoxy<\/text><text x=\"375\" y=\"254\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"400\">FR-5 \u00b7 epoxy<\/text><text x=\"35\" y=\"365\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"23\" fill=\"#17394b\" font-weight=\"400\">Family names are not an overall quality ranking.<\/text><\/svg><figcaption>Explanatory diagram \u2014 FR-1, FR-2 and FR-3 use paper; FR-4 and FR-5 use woven glass. The resin and grade requirements must also be specified. Not a production measurement.<\/figcaption><\/figure><p>For a <a href=\"https:\/\/www.raypcb.com\/multilayer-pcb\/\">multilayer<\/a> rigid board, glass-epoxy systems provide a familiar construction route using cores and compatible prepregs. The resin system, glass construction and processing details still matter. The <a href=\"https:\/\/www.raypcb.com\/fr4-pcb\/\">FR-4 PCB construction overview<\/a> addresses that manufacturing route; this page concentrates on the differences between the FR families.<\/p><\/section>\n<section><h2>Do not confuse an FR grade with a UL 94 rating<\/h2><p>\u201cFR\u201d identifies flame-retardant material grades in this context. It does not mean fireproof, and the numbers 1 through 5 are not a flame-resistance ranking. A material&#8217;s flammability classification must be read from the applicable product documentation and recognition record, including its tested thickness and other conditions.<\/p><p><a href=\"https:\/\/www.ul.com\/services\/combustion-fire-tests-plastics\/\">UL&#8217;s explanation of plastics flammability testing<\/a> distinguishes different test methods and classifications. For example, VTM classifications for thin materials are not interchangeable with the corresponding V classifications. It is therefore misleading to assign every FR-1 material \u201cfair\u201d flame resistance and every FR-4 material \u201cbest\u201d without an actual test basis.<\/p><p>A supplier&#8217;s laminate recognition also does not automatically certify a finished electronic product. Ask which material and board recognition applies to the proposed construction and what documentation the product approval process requires. If the design needs a particular class at a particular thickness, state those requirements explicitly rather than assuming they follow from the family name.<\/p><\/section>\n<section id=\"fr-thermal\"><h2>Separate Tg, decomposition, expansion and long-term use<\/h2><p>Temperature comparisons become useful only when the property and test method are identified. Glass transition temperature, Tg, describes a transition in the resin&#8217;s behavior. Decomposition temperature, Td, describes degradation under a defined test criterion. Neither is a universal maximum continuous operating temperature for an assembled PCB.<\/p><p>Expansion through the board thickness affects the copper interconnect structure during thermal excursions. A laminate can have an attractive Tg value yet require a closer review of its expansion behavior, moisture condition and repeated soldering exposure. The board construction and plated holes must survive the manufacturing and service conditions together.<\/p><div class=\"table-wrap\" role=\"region\" aria-label=\"Thermal specification meanings\" tabindex=\"0\"><table><thead><tr><th>Property<\/th><th>What it helps evaluate<\/th><th>What it does not establish alone<\/th><\/tr><\/thead><tbody><tr><td>Tg and test method<\/td><td>Resin transition behavior and comparisons made on a consistent basis<\/td><td>Continuous operating temperature or guaranteed reflow durability<\/td><\/tr><tr><td>Td and weight-loss criterion<\/td><td>Material decomposition behavior under the stated test<\/td><td>An acceptable assembly peak temperature<\/td><\/tr><tr><td>Z-axis expansion<\/td><td>Strain imposed on through-thickness interconnections<\/td><td>Finished-board lifetime without construction and cycling evidence<\/td><\/tr><tr><td><a href=\"https:\/\/www.raypcb.com\/pcb-delamination\/\">Delamination<\/a> test data<\/td><td>Resistance under defined thermal test conditions<\/td><td>Unlimited rework or arbitrary soldering profiles<\/td><\/tr><tr><td>Applicable thermal index<\/td><td>Long-term material performance within its recognition conditions<\/td><td>The operating rating of every component or complete product<\/td><\/tr><\/tbody><\/table><\/div><figure><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"680\" height=\"400\" viewBox=\"0 0 680 400\" role=\"img\" aria-labelledby=\"d4-fr-thermal-title d4-fr-thermal-desc\"><title id=\"d4-fr-thermal-title\">Read the property and its test method<\/title><desc id=\"d4-fr-thermal-desc\">Tg, decomposition, expansion and long-term thermal performance answer different questions. One number cannot replace the complete requirement.<\/desc><rect width=\"680\" height=\"400\" fill=\"#f5f9fb\"\/><text x=\"24\" y=\"38\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"700\">Read the property and its test method<\/text><rect x=\"30\" y=\"82\" width=\"285\" height=\"110\" rx=\"5\" fill=\"#edf4f7\" stroke=\"#8aabba\" stroke-width=\"2\"\/><text x=\"48\" y=\"121\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"30\" fill=\"#17394b\" font-weight=\"700\">Tg<\/text><text x=\"48\" y=\"162\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"24\" fill=\"#17394b\" font-weight=\"400\">Resin transition<\/text><rect x=\"354\" y=\"82\" width=\"295\" height=\"110\" rx=\"5\" fill=\"#edf4f7\" stroke=\"#8aabba\" stroke-width=\"2\"\/><text x=\"372\" y=\"121\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"30\" fill=\"#17394b\" font-weight=\"700\">Td<\/text><text x=\"372\" y=\"162\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"22\" fill=\"#17394b\" font-weight=\"400\">Decomposition criterion<\/text><rect x=\"30\" y=\"228\" width=\"285\" height=\"110\" rx=\"5\" fill=\"#edf4f7\" stroke=\"#8aabba\" stroke-width=\"2\"\/><text x=\"48\" y=\"267\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"700\">Z-axis expansion<\/text><text x=\"48\" y=\"309\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"23\" fill=\"#17394b\" font-weight=\"400\">Interconnect strain<\/text><rect x=\"354\" y=\"228\" width=\"295\" height=\"110\" rx=\"5\" fill=\"#edf4f7\" stroke=\"#8aabba\" stroke-width=\"2\"\/><text x=\"372\" y=\"267\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"26\" fill=\"#17394b\" font-weight=\"700\">Thermal index<\/text><text x=\"372\" y=\"309\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"23\" fill=\"#17394b\" font-weight=\"400\">Long-term conditions<\/text><\/svg><figcaption>Explanatory diagram \u2014 Tg, decomposition, expansion and long-term thermal performance answer different questions. One number cannot replace the complete requirement. Not a production measurement.<\/figcaption><\/figure><p>A useful counterexample to \u201cFR-5 means every high-Tg board\u201d is <a href=\"https:\/\/www.isola-group.com\/pcb-laminates-prepreg\/370hr-laminate-prepreg\/\">Isola 370HR<\/a>. The manufacturer describes it as an FR-4 system and lists a typical DSC Tg of 180\u00b0C and a typical Td of 340\u00b0C using a 5% weight-loss criterion. These are properties of that named product under stated methods, not values to assign to all FR-4 laminates or acceptance limits for an unspecified board.<\/p><p>The <a href=\"https:\/\/thegundcompany.com\/wp-content\/uploads\/2023\/03\/High-Temperature-Glass-Epoxy-White-Paper-compressed.pdf\">Gund glass-epoxy comparison<\/a> discusses NEMA and IEC material classifications and the need for comparable test evidence. Use the exact classification required by the design or purchasing specification. Do not rename a high-Tg FR-4 laminate \u201cFR-5\u201d based only on one temperature number.<\/p><p>When considering a dedicated <a href=\"https:\/\/www.raypcb.com\/fr5-pcb\/\">FR-5 PCB requirement<\/a>, first establish why that grade is specified and whether the offered copper-clad system meets it. A substitution review should address all relevant properties and available constructions, not merely match or exceed Tg.<\/p><\/section>\n<section id=\"fr-electrical\"><h2>Compare dielectric data at the frequency and construction that matter<\/h2><p>A single generic <a href=\"https:\/\/www.raypcb.com\/pcb-dielectric-constant\/\">dielectric constant<\/a> cannot accurately describe every FR-4 product. Resin content, glass construction, frequency and test method influence published data and the model used for a finished board. For <a href=\"https:\/\/www.raypcb.com\/controlled-impedance\/\">controlled impedance<\/a>, ask for the proposed stackup and the data the fabricator will use for that construction. A catalog value and a design value are not automatically interchangeable.<\/p><p>Loss tangent is also a condition-dependent property. FR-5 should not be assumed to provide lower high-frequency loss than every FR-4 material. If the project has an insertion-loss requirement, compare suitable named materials and copper constructions at relevant frequencies. Define the channel requirement before choosing a material family from a list.<\/p><p>For insulation performance, review the required voltage, spacing, environment and contamination conditions. Moisture resistance, tracking behavior and board cleanliness answer different questions from Dk and Df. A lower Dk does not by itself make a board safer at high voltage, and a flame-retardant designation does not establish creepage or clearance.<\/p><p>Keep the electrical review proportionate to the application. A simple low-frequency control board and a fast serial channel may both use glass epoxy, but they need different evidence. Over-specifying a laminate without a defined failure mechanism can increase sourcing constraints without resolving the real design risk.<\/p><\/section>\n<section id=\"fr-scenarios\"><h2>Apply the comparison to three purchasing situations<\/h2><h3>A simple single-sided legacy control board<\/h3><p>Begin with the material already called out in the approved drawing. Confirm that the intended supplier offers the specified copper-clad grade, thickness and <a href=\"https:\/\/www.raypcb.com\/copper-weight-pcb\/\">copper weight<\/a>. Check the soldering process, operating environment and mechanical features. If punched features are part of the design, verify the relevant processing conditions rather than assuming any inexpensive paper laminate will behave identically.<\/p><p>A move from paper phenolic to glass epoxy may change fabrication methods, tooling assumptions and cost. It can be appropriate, but it is an engineering change that requires review. Do not infer the material reliably from board color, <a href=\"https:\/\/www.raypcb.com\/how-to-know-the-surface-finish-from-pcb-color\/\">surface finish<\/a> or a photograph of an old assembly.<\/p><h3>A multilayer controller with plated through-holes<\/h3><p>Specify a compatible core\/prepreg system, stackup, final thickness and copper requirements. Review the assembly thermal history, expected rework and service cycling alongside plated-hole construction. If an impedance requirement exists, include its tolerance and measurement scope. The <a href=\"https:\/\/www.raypcb.com\/multilayer-fr4-pcb\/\">multilayer FR-4 guide<\/a> is the more appropriate next step than comparing generic family numbers again.<\/p><p>Ask for a proposed named laminate and any permitted alternatives before fabrication. \u201cEquivalent FR-4\u201d should lead to a documented comparison and approval, especially where a change affects electrical modeling, recognition or an already qualified process.<\/p><h3>A design calling for higher-temperature operation<\/h3><p>Identify the actual stress first: repeated reflow, local component heating, high ambient temperature or long-term thermal cycling. Those are different requirements. Review the laminate, copper interconnections, solder joints and component ratings as a system. A board material with a higher Tg cannot correct an overheated component or an inadequate thermal path by itself.<\/p><p>If the existing requirement explicitly calls for FR-5, preserve that requirement until the design owner approves a change. If the requirement merely says \u201chigh temperature,\u201d replace the ambiguity with measurable conditions and suitable evidence. Avoid adding a high-temperature grade name as a substitute for defining the product&#8217;s operating limits.<\/p><figure><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"680\" height=\"400\" viewBox=\"0 0 680 400\" role=\"img\" aria-labelledby=\"d4-fr-spec-title d4-fr-spec-desc\"><title id=\"d4-fr-spec-title\">From family to a released requirement<\/title><desc id=\"d4-fr-spec-desc\">Choose a family, compare named products, then release the approved construction and substitution rules.<\/desc><rect width=\"680\" height=\"400\" fill=\"#f5f9fb\"\/><text x=\"24\" y=\"38\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"700\">From family to a released requirement<\/text><rect x=\"30\" y=\"80\" width=\"620\" height=\"74\" rx=\"5\" fill=\"#edf4f7\" stroke=\"#8aabba\" stroke-width=\"2\"\/><text x=\"48\" y=\"111\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"26\" fill=\"#17394b\" font-weight=\"700\">1  Family<\/text><text x=\"260\" y=\"112\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"25\" fill=\"#17394b\" font-weight=\"400\">Reinforcement + resin<\/text><rect x=\"30\" y=\"182\" width=\"620\" height=\"74\" rx=\"5\" fill=\"#edf4f7\" stroke=\"#8aabba\" stroke-width=\"2\"\/><text x=\"48\" y=\"214\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"26\" fill=\"#17394b\" font-weight=\"700\">2  Product<\/text><text x=\"260\" y=\"213\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"23\" fill=\"#17394b\" font-weight=\"400\">Manufacturer + grade + data<\/text><rect x=\"30\" y=\"284\" width=\"620\" height=\"74\" rx=\"5\" fill=\"#edf4f7\" stroke=\"#8aabba\" stroke-width=\"2\"\/><text x=\"48\" y=\"315\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"26\" fill=\"#17394b\" font-weight=\"700\">3  Build<\/text><text x=\"260\" y=\"315\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"23\" fill=\"#17394b\" font-weight=\"400\">Stackup + approval conditions<\/text><line x1=\"340\" y1=\"158\" x2=\"340\" y2=\"178\" stroke=\"#006b94\" stroke-width=\"4\"\/><line x1=\"340\" y1=\"260\" x2=\"340\" y2=\"280\" stroke=\"#006b94\" stroke-width=\"4\"\/><\/svg><figcaption>Explanatory diagram \u2014 Choose a family, compare named products, then release the approved construction and substitution rules. Not a production measurement.<\/figcaption><\/figure><\/section>\n<section id=\"fr-purchase\"><h2>Turn the family choice into an orderable specification<\/h2><p>A useful fabrication note identifies the material manufacturer and grade where required, the applicable material specification, finished thickness and tolerance, copper requirements, layer stackup and any controlled-impedance conditions. It also identifies permitted substitutions and who must approve them. Distinguish a mandatory requirement from a suggested starting point so the quotation can answer the actual design need.<\/p><p>Ask the supplier to flag unavailable constructions before work begins. A datasheet showing that a material exists does not establish present stock, lead time, available prepregs or a manufacturer&#8217;s experience with your exact stackup. Those are project-specific sourcing and process questions. No universal FR-1-to-FR-5 price multiplier can replace a quote for the specified board.<\/p><fieldset><legend>Material comparison checklist<\/legend><p>Use these temporary checks during a drawing review. They do not save data or create a material approval.<\/p><label><input type=\"checkbox\">The reinforcement and resin family match the intended construction.<\/label><label><input type=\"checkbox\">A named copper-clad laminate and compatible <a href=\"https:\/\/www.raypcb.com\/prepreg-pcb\/\">prepreg<\/a> system are identified where needed.<\/label><label><input type=\"checkbox\">Thermal properties include test methods and are separated from product operating limits.<\/label><label><input type=\"checkbox\">Electrical values match the frequency, construction and design purpose.<\/label><label><input type=\"checkbox\">Flammability and recognition requirements include their applicable conditions.<\/label><label><input type=\"checkbox\">Substitution approval, availability and requested documentation are clear.<\/label><\/fieldset><p>For a <a href=\"https:\/\/www.raypcb.com\/pcb-manufacturing\/\">PCB manufacturing review<\/a>, provide the fabrication files, layer count, stackup, quantity and assembly conditions. Include the existing material callout and any required test or recognition documents. RAYPCB can review the requested construction and sourcing scope against the project; this family comparison does not certify a proposed substitute.<\/p><p><a class=\"cta\" href=\"https:\/\/www.raypcb.com\/contact\/\">Review a PCB material requirement<\/a><\/p><\/section>\n<section><h2>Common questions<\/h2><details><summary>Is FR-3 made from <a href=\"https:\/\/www.raypcb.com\/fiberglass-pcb\/\">fiberglass<\/a>?<\/summary><p>No. The FR-3 family discussed here uses paper reinforcement with epoxy resin. Woven-glass epoxy belongs to the FR-4 and FR-5 comparison. Verify the exact supplier designation if a drawing uses an unfamiliar name.<\/p><\/details><details><summary>Is FR-5 always better than FR-4?<\/summary><p>No. \u201cBetter\u201d requires a particular thermal, electrical or mechanical requirement. Compare qualified products and constructions. A grade designation does not guarantee lower loss, lower cost or easier sourcing.<\/p><\/details><details><summary>Can every high-Tg FR-4 laminate be ordered as FR-5?<\/summary><p>No. Tg alone does not establish a material classification. Specify the required grade and applicable product evidence; do not relabel material families using a temperature threshold.<\/p><\/details><details><summary>Does FR-4 mean halogen-free?<\/summary><p>No. If a halogen-free requirement applies, specify the applicable criteria and request documentation for the exact material. The FR-4 family name alone does not settle resin formulation or that requirement.<\/p><\/details><\/section>\n<section class=\"sources\"><h2>Source and revision notes<\/h2><p>This revision preserves the original FR-family comparison topic and corrects the FR-3 description and unsupported grade rankings. References include <a href=\"https:\/\/www.lamitex.com\/blog\/lamitex-r-nema-grade-fr-1-fr-2-fr-3\">Lamitex material descriptions<\/a>, <a href=\"https:\/\/thegundcompany.com\/wp-content\/uploads\/2023\/03\/High-Temperature-Glass-Epoxy-White-Paper-compressed.pdf\">Gund classification guidance<\/a>, <a href=\"https:\/\/www.isola-group.com\/pcb-laminates-prepreg\/370hr-laminate-prepreg\/\">Isola&#8217;s named-product data<\/a> and <a href=\"https:\/\/www.ul.com\/services\/combustion-fire-tests-plastics\/\">UL test explanations<\/a>. Figures are original explanatory diagrams, not material micrographs or certification evidence. Reviewed October 10, 2026.<\/p><\/section>\n<\/article>\n","protected":false},"excerpt":{"rendered":"<p>RAYPCB \u00b7 PCB MATERIAL SELECTION FR-1, FR-2, FR-3, FR-4 and FR-5: Material Differences and Selection FR-1 and FR-2 are paper-reinforced phenolic laminates; FR-3 uses paper with epoxy resin. FR-4 and FR-5 use woven glass with epoxy resin. These grade names describe material families. They do not create a universal ladder of signal performance, flame resistance [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":13045,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-28972","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FR-1 vs FR-2 vs FR-3 vs FR-4 vs FR-5 PCB Materials<\/title>\n<meta name=\"description\" content=\"Compare FR-1 to FR-5 reinforcement, resin and selection requirements. Understand FR-3, high-Tg FR-4, FR-5, thermal data and material specifications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.raypcb.com\/pcb-fr4-material\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FR-1 vs FR-2 vs FR-3 vs FR-4 vs FR-5 PCB Materials\" \/>\n<meta property=\"og:description\" content=\"Compare FR-1 to FR-5 reinforcement, resin and selection requirements. Understand FR-3, high-Tg FR-4, FR-5, thermal data and material specifications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.raypcb.com\/pcb-fr4-material\/\" \/>\n<meta property=\"og:site_name\" content=\"RayPCB\" \/>\n<meta property=\"article:published_time\" content=\"2023-11-24T05:46:08+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-10T03:40:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.raypcb.com\/wp-content\/uploads\/2021\/09\/fr4-pcb.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"RAYPCB\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"RAYPCB\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/\"},\"author\":{\"name\":\"RAYPCB\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"headline\":\"FR-1, FR-2, FR-3, FR-4 and FR-5: Material Differences and Selection\",\"datePublished\":\"2023-11-24T05:46:08+00:00\",\"dateModified\":\"2026-10-10T03:40:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/\"},\"wordCount\":2050,\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/fr4-pcb.jpg\",\"articleSection\":[\"Blogs\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/\",\"name\":\"FR-1 vs FR-2 vs FR-3 vs FR-4 vs FR-5 PCB Materials\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/fr4-pcb.jpg\",\"datePublished\":\"2023-11-24T05:46:08+00:00\",\"dateModified\":\"2026-10-10T03:40:12+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"description\":\"Compare FR-1 to FR-5 reinforcement, resin and selection requirements. Understand FR-3, high-Tg FR-4, FR-5, thermal data and material specifications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/fr4-pcb.jpg\",\"contentUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/fr4-pcb.jpg\",\"width\":1920,\"height\":800,\"caption\":\"fr4 pcb\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/pcb-fr4-material\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.raypcb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FR-1, FR-2, FR-3, FR-4 and FR-5: Material Differences and Selection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/\",\"name\":\"RayPCB\",\"description\":\"PCB manufacturer and PCB assembly\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.raypcb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\",\"name\":\"RAYPCB\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"caption\":\"RAYPCB\"},\"sameAs\":[\"https:\\\/\\\/www.raypcb.com\"],\"url\":\"https:\\\/\\\/www.raypcb.com\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FR-1 vs FR-2 vs FR-3 vs FR-4 vs FR-5 PCB Materials","description":"Compare FR-1 to FR-5 reinforcement, resin and selection requirements. Understand FR-3, high-Tg FR-4, FR-5, thermal data and material specifications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.raypcb.com\/pcb-fr4-material\/","og_locale":"en_US","og_type":"article","og_title":"FR-1 vs FR-2 vs FR-3 vs FR-4 vs FR-5 PCB Materials","og_description":"Compare FR-1 to FR-5 reinforcement, resin and selection requirements. Understand FR-3, high-Tg FR-4, FR-5, thermal data and material specifications.","og_url":"https:\/\/www.raypcb.com\/pcb-fr4-material\/","og_site_name":"RayPCB","article_published_time":"2023-11-24T05:46:08+00:00","article_modified_time":"2026-10-10T03:40:12+00:00","og_image":[{"width":1920,"height":800,"url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2021\/09\/fr4-pcb.jpg","type":"image\/jpeg"}],"author":"RAYPCB","twitter_card":"summary_large_image","twitter_misc":{"Written by":"RAYPCB","Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/#article","isPartOf":{"@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/"},"author":{"name":"RAYPCB","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"headline":"FR-1, FR-2, FR-3, FR-4 and FR-5: Material Differences and Selection","datePublished":"2023-11-24T05:46:08+00:00","dateModified":"2026-10-10T03:40:12+00:00","mainEntityOfPage":{"@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/"},"wordCount":2050,"image":{"@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2021\/09\/fr4-pcb.jpg","articleSection":["Blogs"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/","url":"https:\/\/www.raypcb.com\/pcb-fr4-material\/","name":"FR-1 vs FR-2 vs FR-3 vs FR-4 vs FR-5 PCB Materials","isPartOf":{"@id":"https:\/\/www.raypcb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/#primaryimage"},"image":{"@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2021\/09\/fr4-pcb.jpg","datePublished":"2023-11-24T05:46:08+00:00","dateModified":"2026-10-10T03:40:12+00:00","author":{"@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"description":"Compare FR-1 to FR-5 reinforcement, resin and selection requirements. Understand FR-3, high-Tg FR-4, FR-5, thermal data and material specifications.","breadcrumb":{"@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.raypcb.com\/pcb-fr4-material\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/#primaryimage","url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2021\/09\/fr4-pcb.jpg","contentUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2021\/09\/fr4-pcb.jpg","width":1920,"height":800,"caption":"fr4 pcb"},{"@type":"BreadcrumbList","@id":"https:\/\/www.raypcb.com\/pcb-fr4-material\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.raypcb.com\/"},{"@type":"ListItem","position":2,"name":"FR-1, FR-2, FR-3, FR-4 and FR-5: Material Differences and Selection"}]},{"@type":"WebSite","@id":"https:\/\/www.raypcb.com\/#website","url":"https:\/\/www.raypcb.com\/","name":"RayPCB","description":"PCB manufacturer and PCB assembly","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.raypcb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f","name":"RAYPCB","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","caption":"RAYPCB"},"sameAs":["https:\/\/www.raypcb.com"],"url":"https:\/\/www.raypcb.com\/author\/admin\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2021\/09\/fr4-pcb.jpg","_links":{"self":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/28972","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/comments?post=28972"}],"version-history":[{"count":1,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/28972\/revisions"}],"predecessor-version":[{"id":122015,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/28972\/revisions\/122015"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media\/13045"}],"wp:attachment":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media?parent=28972"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/categories?post=28972"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/tags?post=28972"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}