{"id":29324,"date":"2024-01-02T06:46:13","date_gmt":"2024-01-02T06:46:13","guid":{"rendered":"https:\/\/www.raypcb.com\/?p=29324"},"modified":"2026-09-27T11:09:47","modified_gmt":"2026-09-27T11:09:47","slug":"bed-of-nails-test-fixture","status":"publish","type":"post","link":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/","title":{"rendered":"What is Bed of Nails Test Fixture?"},"content":{"rendered":"<div class=\"ppx-page ppx-page--lab\"><header class=\"ppx-hero\"><div class=\"ppx-wrap\"><p class=\"ppx-breadcrumb\"><a href=\"https:\/\/www.raypcb.com\/pcb-assembly\/\">PCB Assembly<\/a> \/ <a href=\"https:\/\/www.raypcb.com\/ict-test\/\">ICT testing<\/a><\/p><div class=\"ppx-hero-grid\"><div><p class=\"ppx-kicker\">RAYPCB \u00b7 ENGINEERING REFERENCE<\/p><h1>Bed-of-Nails Test Fixtures: Access, Force &amp; Handoff<\/h1><p class=\"ppx-lead\">Plan bed-of-nails fixture access and probe force. Separate contact counts from fault coverage and prepare the data needed for a repeatable production test.<\/p><div class=\"ppx-actions\"><a class=\"ppx-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Discuss your requirements<\/a><a class=\"ppx-btn ppx-secondary\" href=\"#tool\">Open the worksheet<\/a><\/div><p class=\"ppx-note\">Original engineering guidance \u00b7 References checked September 27, 2026<\/p><\/div><figure class=\"ppx-figure ppx-diagram\"><a class=\"ppx-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/fixture-access-map.svg\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/fixture-access-map.svg\" width=\"1200\" height=\"660\" loading=\"eager\" alt=\"Physical probes are not the same as unique accessible nets\"><\/a><figcaption>A simplified contact\/net map. Multiple contacts on one net do not add unique-net access.<\/figcaption><\/figure><\/div><\/div><\/header><nav class=\"ppx-nav\" aria-label=\"On this page\"><div class=\"ppx-wrap\"><a href=\"#answer\">Key answer<\/a><a href=\"#reference\">Engineering reference<\/a><a href=\"#tool\">Interactive worksheet<\/a><a href=\"#questions\">Questions<\/a><\/div><\/nav><section class=\"ppx-section\" id=\"answer\"><div class=\"ppx-wrap\"><div class=\"ppx-prose\"><h2>A bed-of-nails fixture makes repeatable electrical contact<\/h2><p>A bed-of-nails test fixture uses an arranged set of spring-loaded probes to contact defined locations on an assembly. The fixture locates and supports the board, controls probe travel and connects those contacts to a test or <a href=\"https:\/\/www.raypcb.com\/how-to-do-ic-programming-during-pcba-processing\/\">programming<\/a> system. It can support in-circuit testing, selected functional measurements or programming, depending on the electrical design and test program.<\/p><p>The fixture is not the test strategy itself. Contacting a point does not establish which faults can be detected through it. Likewise, counting probes does not measure test coverage: several probes may contact the same power net, while an important signal remains inaccessible.<\/p><p>This page concentrates on physical access, mechanical loading, fixture data and maintainability. The <a href=\"https:\/\/www.raypcb.com\/ict-test\/\">ICT testing guide<\/a> owns the broader discussion of in-circuit measurement and coverage. Use both when preparing a production test plan, but keep their decisions separate.<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"reference\"><div class=\"ppx-wrap ppx-lab\"><h2>Separate the fixture's three jobs<\/h2><div class=\"ppx-prose\"><div class=\"ppx-table\" tabindex=\"0\" role=\"region\" aria-label=\"Engineering reference table\"><table><thead><tr><th scope=\"col\">Fixture responsibility<\/th><th scope=\"col\">What must be defined<\/th><th scope=\"col\">What a simple probe count cannot tell you<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Locate the assembly<\/th><td>Datums, orientation, tooling features and tolerances<\/td><td>Whether all target locations remain aligned<\/td><\/tr><tr><th scope=\"row\">Make reliable contact<\/th><td>Probe type, target geometry, working stroke and surface condition<\/td><td>Whether resistance and signal quality meet the test need<\/td><\/tr><tr><th scope=\"row\">Support the test operation<\/th><td>Wiring, shielding, switching, power and test program<\/td><td>Which electrical faults the complete system can detect<\/td><\/tr><\/tbody><\/table><\/div><p>A board can fit mechanically while the electrical test remains ineffective. For example, a probe may touch a pad that belongs to the intended net but is unsuitable for a sensitive measurement because of the path, current return or surrounding circuit. Conversely, an electrically useful test point may be inaccessible after a tall component is installed.<\/p><p>Review the fixture at the assembly stage where it will be used. Components, solder, labels, coating and enclosure features can all change access. Use the released assembly data rather than the bare-board outline alone. If programming or calibration shares the fixture, include those requirements before the mechanical design is frozen.<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"access\"><div class=\"ppx-wrap ppx-lab\"><h2>Design the target and its surroundings together<\/h2><div class=\"ppx-prose\"><p>Start with a test-point list linked to the netlist and assembly revision. For each intended contact, identify the board side, coordinates, target geometry, relevant surface condition and purpose. Include the origin, units and rotation convention so the fixture designer can reconcile the list with the CAD and mechanical data.<\/p><p>There is no single pad diameter, pitch or edge distance that is suitable for every probe and fixture. Select targets using the actual probe family, tooling accuracy, assembly tolerances and available support. Smaller features can increase fixture complexity and reduce tolerance margin. A quoted minimum capability should be reviewed in the actual construction rather than treated as a universal design preference.<\/p><p>Keep solder mask, coating and mechanical features consistent with the target definition. A coordinate may remain unchanged while a mask opening or coating boundary makes the point unusable. If probing occurs before protection, document that sequence; if it must occur afterward, provide controlled access.<\/p><p>Review adjacent components and the approach path, not just the center of the pad. The probe, socket, guide plate and support structure occupy space. A contact near a board edge or cutout may also need special mechanical support to prevent local movement.<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"tool\"><div class=\"ppx-wrap\"><div class=\"ppx-prose\"><h2>Check force arithmetic, access counts and ideal cycle output<\/h2><p>The worksheet sums the entered probe force, adds other opposing loads and compares the result with a derated vacuum-force model. It also separates unique-net access from physical probe count. Use the values from the proposed probe schedule and fixture geometry, not a generic maximum from another product.<\/p><p>Interactive engineering tool available on the website.<\/p><p>A positive force margin means only that the entered scalar model has more available actuation force than opposing load. It does not prove acceptable board strain, adequate local support, seal integrity or dynamic performance. A negative margin is a clear prompt to review the assumptions and actuation concept; it is not a complete fixture diagnosis.<\/p><p>The ideal output calculation uses the full station cycle and the number of boards processed per cycle. Include loading, clamping, testing and unloading in that time. The result excludes downtime, retest, scrap and other production losses, so it must not be presented as guaranteed throughput.<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"force\"><div class=\"ppx-wrap ppx-lab\"><h2>A worked example exposes the important units<\/h2><div class=\"ppx-prose\"><p>Consider an illustrative fixture with 150 identical probes at 1 N each at the actual working stroke. The summed probe force is 150 N. Add an entered 30 N for other opposing loads and the total modeled resistance to actuation becomes 180 N.<\/p><p>If the effective sealed actuation area is 100 cm\u00b2 and the vacuum pressure difference is 60 kPa, the ideal pressure force is 60 \u00d7 100 \u00d7 0.1 = 600 N. Applying an illustrative 70% derating gives 420 N. The scalar margin is therefore 240 N. The 70% factor is an example input, not a fixture design standard or a recommended safety factor.<\/p><p>The pressure input is the difference across the effective actuation area. It is not an absolute-pressure reading entered without conversion, and the area is not automatically the entire board outline. Cutouts, seals and the fixture mechanism affect the appropriate definition. Confirm these inputs with the fixture designer.<\/p><figure class=\"ppx-figure ppx-diagram\"><a class=\"ppx-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/fixture-force-path.svg\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/fixture-force-path.svg\" width=\"1200\" height=\"660\" loading=\"lazy\" alt=\"Global actuation force does not prove local board support\"><\/a><figcaption>Conceptual probe loading and a support. No stress, strain or deflection simulation is performed.<\/figcaption><\/figure><p>The official <a href=\"https:\/\/www.qatech.com\/en\/resources-general\/spring-force-considerations.html\" target=\"_blank\" rel=\"noopener\">QA Technology spring-force guidance<\/a> explains why working stroke and force distribution matter. Use the actual probe data and design conditions. A total-force sum cannot show whether a dense cluster of probes overloads a thin or poorly supported region.<\/p><p>For mixed probe types, calculate the sum of their individual working forces or use a documented equivalent average. Do not average force ratings without considering the number and operating stroke of each type. Include other opposing springs or mechanisms explicitly rather than hiding them in an unexplained allowance.<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"support\"><div class=\"ppx-wrap ppx-lab\"><h2>Board support is part of the measurement system<\/h2><div class=\"ppx-prose\"><figure class=\"ppx-figure ppx-photo\"><a class=\"ppx-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/fixture-contact-reference.webp\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/fixture-contact-reference.webp\" width=\"1024\" height=\"432\" loading=\"lazy\" alt=\"Probe fixture above a populated circuit board\"><\/a><figcaption>Existing site photograph of a test-fixture contact arrangement. It does not establish a probe map, test coverage or fixture qualification.<\/figcaption><\/figure><p>A fixture should support the assembly in a repeatable way while keeping pressure away from vulnerable component regions. The locations of probes, supports, clamps and datums interact. Moving a support can change board deflection and contact consistency even when the probe map is unchanged.<\/p><p>Review component height and keep-outs on both sides. A support that appears clear in a bare-board drawing may collide with a component or solder feature in the assembled product. Mechanical drawings should identify the state of the product and the relevant tolerances, including any panelization or breakaway features remaining during test.<\/p><p>The <a href=\"https:\/\/qatech.com\/pdfs\/Resources\/APP_Verify_Probe_Stroke_ANQ120-A.pdf\" target=\"_blank\" rel=\"noopener\">QA Technology application note on verifying probe stroke<\/a> describes checking that probes operate at the intended travel. This is useful evidence during fixture acceptance and maintenance. It is not enough to choose a probe with adequate nominal length and assume that every installed contact operates correctly.<\/p><p>Where board strain or fragile components are a concern, define the validation method with the responsible engineering team. The simple force worksheet cannot calculate local strain, package stress or deflection. Record the actual acceptance evidence rather than calling a positive force margin \u201cmechanically safe.\u201d<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"coverage\"><div class=\"ppx-wrap ppx-lab\"><h2>Physical access and fault detection need different denominators<\/h2><div class=\"ppx-prose\"><p>Suppose a test plan requires access to 150 unique nets and the proposed fixture reaches 120. Physical unique-net access is 80%. If the fixture uses 170 probes because some power and ground nets need multiple contacts, the extra probes do not raise unique-net access above 80%.<\/p><p>Fault coverage is a separate assessment. It depends on the circuit, test program, stimulus, measurement limits and the fault model. Some faults can be detected indirectly; others remain hidden despite physical contact. A coverage statement should name what is included, what is excluded and how the analysis was produced.<\/p><p><a href=\"https:\/\/www.keysight.com\/gb\/en\/products\/in-circuit-test-systems.wim.html\" target=\"_blank\" rel=\"noopener\">Keysight&#x27;s in-circuit test systems information<\/a> shows that ICT is a test-system discipline, not simply a mechanical pin array. In a project review, ask for a coverage report or agreed test matrix rather than accepting the percentage of contacted pads as proof of complete testing.<\/p><p>For signals that cannot be reached, evaluate the appropriate alternative with the test engineer. This might involve a layout change, boundary-scan capability, another measurement route or a documented coverage gap. Do not silently classify an inaccessible net as tested because nearby nodes are available.<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"records\"><div class=\"ppx-wrap ppx-lab\"><h2>Give the fixture designer a coherent release package<\/h2><div class=\"ppx-prose\"><figure class=\"ppx-figure ppx-photo\"><a class=\"ppx-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/inspection-workstation-reference.webp\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/inspection-workstation-reference.webp\" width=\"600\" height=\"360\" loading=\"lazy\" alt=\"Optical inspection at an assembly workstation\"><\/a><figcaption>Existing RAYPCB site inspection reference; no specific certification, sampling plan or acceptance result is inferred.<\/figcaption><\/figure><p>The package should include the board and assembly revisions, netlist, test-point data, board outline, tooling features, component placement and relevant three-dimensional keep-outs. Add the test strategy, target quantities, expected cycle, programming needs and required traceability. State whether the fixture handles individual boards or a panel.<\/p><p>Coordinate definitions deserve a deliberate check. Units, origin, side conventions and mirrored views can produce a fixture that is internally consistent but wrong for the released board. Include a small set of identifiable reference features so the designer can verify the transformation before manufacture.<\/p><p>Electrical requirements should name the purpose of each special contact. Current-carrying paths, precision measurements, high-frequency signals and programming interfaces may need different wiring and probe arrangements. A generic connection list without measurement context can result in a fixture that touches every point but does not deliver stable results.<\/p><p>Use the <a href=\"https:\/\/www.raypcb.com\/required-files-for-pcba-printed-circuit-board-assembly\/\">PCBA release-file guide<\/a> to align the fixture package with the manufacturing release. Changes to the assembly should trigger a review of both the test program and physical tooling.<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"maintenance\"><div class=\"ppx-wrap ppx-lab\"><h2>Design for diagnosis, cleaning and controlled replacement<\/h2><div class=\"ppx-prose\"><figure class=\"ppx-figure ppx-diagram\"><a class=\"ppx-image-link\" href=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/fixture-maintenance-route.svg\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/assembly-postprocess\/fixture-maintenance-route.svg\" width=\"1200\" height=\"660\" loading=\"lazy\" alt=\"A fixture has a controlled operating lifecycle\"><\/a><figcaption>A reference board and fixture both need identity, revision and maintenance controls.<\/figcaption><\/figure><p>Probe wear, contamination, socket condition, wiring and mechanical alignment can affect contact quality over time. Define how the fixture is inspected, cleaned and verified, using the selected probe and equipment guidance. Do not assume that a fixture remains qualified indefinitely because it passed an initial trial.<\/p><p>A useful failure record separates product defects from fixture-related observations. Track the affected location, symptom, fixture identity and action taken. Replacing a probe may resolve an intermittent contact, but the original failure should remain in the record so repeated problems can be recognized.<\/p><p>Use a controlled verification approach after repair or adjustment. This may include contact checks, known-reference assemblies and the agreed test-system validation. A so-called golden board also needs identity, revision and maintenance controls; it is not automatically a perfect reference forever.<\/p><p>Make replaceable components accessible in the fixture design. If changing one probe requires disturbing many unrelated connections, maintenance can introduce additional variability. Consider spares and documented replacement procedures as part of the fixture&#x27;s operating cost.<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"economics\"><div class=\"ppx-wrap ppx-lab\"><h2>Compare fixed tooling with the complete production cycle<\/h2><div class=\"ppx-prose\"><p>A bed-of-nails fixture commonly involves an initial engineering and tooling investment plus ongoing operation and maintenance. Compare it with alternatives using the actual test requirements, expected volume and revision stability. A low fixture price is not necessarily a low total cost if contact problems cause retests or the board design changes frequently.<\/p><p>For early prototypes, a <a href=\"https:\/\/www.raypcb.com\/pcb-flying-probe-test-fpt\/\">flying-probe test approach<\/a> may address a different access and tooling tradeoff, depending on the intended board state and test scope. Do not assume that a bare-board flying-probe service replaces assembled-board ICT or functional testing. Compare like-for-like fault coverage and measurement requirements.<\/p><p>The ideal cycle model on this page is intentionally simple. A 30-second complete cycle with one board gives 120 boards per hour before losses. A two-board fixture is not automatically twice as productive if loading, programming or shared instrument operations lengthen the cycle. Measure the proposed sequence before making a capacity commitment.<\/p><p>For a quotation, identify the expected build quantities, panel or unit format, test matrix and design-change outlook. Ask which tooling, programming, validation and maintenance items are included. This creates a more useful comparison than requesting a universal price per probe.<\/p><\/div><\/div><\/section><section class=\"ppx-section\" id=\"questions\"><div class=\"ppx-wrap\"><div class=\"ppx-prose\"><h2>Bed-of-nails fixture questions<\/h2><details><summary>Does every probe represent a tested net?<\/summary><p>No. Multiple probes can contact one net, and a contact can serve power, return, programming or measurement. Count unique required nets separately and assess fault coverage through the test program.<\/p><\/details><details><summary>Does a positive force margin prove the fixture is safe?<\/summary><p>No. The worksheet only compares scalar forces under your assumptions. Local loading, board strain, supports, tolerances and dynamic operation require separate engineering verification.<\/p><\/details><details><summary>Can one fixture program and test the board?<\/summary><p>It can, if the electrical interfaces, sequence and records are designed for those tasks. Programming success and functional or in-circuit test results should remain distinguishable.<\/p><\/details><details><summary>Is there one standard test-pad size?<\/summary><p>No single dimension fits every probe and fixture. Use the selected equipment, tolerance stack, assembly geometry and measurement requirements to agree the target design.<\/p><\/details><details><summary>What is the next step for a complete assembly build?<\/summary><p>Prepare the fixture and test requirements alongside the manufacturing files, then request a scoped review through <a href=\"https:\/\/www.raypcb.com\/pcb-assembly\/\">PCB assembly<\/a>. Contact is available without using the worksheet, and its downloaded brief must be attached manually.<\/p><\/details><\/div><\/div><\/section><section class=\"ppx-section\"><div class=\"ppx-wrap\"><div class=\"ppx-enquiry\"><h2>Prepare a scoped assembly review<\/h2><p>Send the board revision, construction, quantity and the inspection, protection, programming or test question you need reviewed. Identify unresolved requirements so the response can address them.<\/p><a class=\"ppx-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Send requirements for review<\/a><p class=\"ppx-note\">Optional: attach the downloaded worksheet manually. This guidance does not certify a design, approve a shipment or replace the applicable authorized standards.<\/p><\/div><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>PCB Assembly \/ ICT testingRAYPCB \u00b7 ENGINEERING REFERENCEBed-of-Nails Test Fixtures: Access, Force &amp; HandoffPlan bed-of-nails fixture access and probe force. Separate contact counts from fault coverage and prepare the data needed for a repeatable production test.Discuss your requirementsOpen the worksheetOriginal engineering guidance \u00b7 References checked&hellip;<\/p>\n","protected":false},"author":1,"featured_media":29325,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-29324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What is Bed of Nails Test Fixture? - RayPCB<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is Bed of Nails Test Fixture? - RayPCB\" \/>\n<meta property=\"og:description\" content=\"PCB Assembly \/ ICT testingRAYPCB \u00b7 ENGINEERING REFERENCEBed-of-Nails Test Fixtures: Access, Force &amp; HandoffPlan bed-of-nails fixture access and probe force. Separate contact counts from fault coverage and prepare the data needed for a repeatable production test.Discuss your requirementsOpen the worksheetOriginal engineering guidance \u00b7 References checked&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/\" \/>\n<meta property=\"og:site_name\" content=\"RayPCB\" \/>\n<meta property=\"article:published_time\" content=\"2024-01-02T06:46:13+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-27T11:09:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.raypcb.com\/wp-content\/uploads\/2024\/01\/bed-of-nails-test-fixture.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"530\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"RAYPCB\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"RAYPCB\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/\"},\"author\":{\"name\":\"RAYPCB\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"headline\":\"What is Bed of Nails Test Fixture?\",\"datePublished\":\"2024-01-02T06:46:13+00:00\",\"dateModified\":\"2026-09-27T11:09:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/\"},\"wordCount\":1132,\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/bed-of-nails-test-fixture.jpg\",\"articleSection\":[\"Blogs\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/\",\"name\":\"What is Bed of Nails Test Fixture? - RayPCB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/bed-of-nails-test-fixture.jpg\",\"datePublished\":\"2024-01-02T06:46:13+00:00\",\"dateModified\":\"2026-09-27T11:09:47+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/bed-of-nails-test-fixture.jpg\",\"contentUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/bed-of-nails-test-fixture.jpg\",\"width\":1280,\"height\":530},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/bed-of-nails-test-fixture\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.raypcb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is Bed of Nails Test Fixture?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/\",\"name\":\"RayPCB\",\"description\":\"PCB manufacturer and PCB assembly\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.raypcb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\",\"name\":\"RAYPCB\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"caption\":\"RAYPCB\"},\"sameAs\":[\"https:\\\/\\\/www.raypcb.com\"],\"url\":\"https:\\\/\\\/www.raypcb.com\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is Bed of Nails Test Fixture? - RayPCB","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/","og_locale":"en_US","og_type":"article","og_title":"What is Bed of Nails Test Fixture? - RayPCB","og_description":"PCB Assembly \/ ICT testingRAYPCB \u00b7 ENGINEERING REFERENCEBed-of-Nails Test Fixtures: Access, Force &amp; HandoffPlan bed-of-nails fixture access and probe force. Separate contact counts from fault coverage and prepare the data needed for a repeatable production test.Discuss your requirementsOpen the worksheetOriginal engineering guidance \u00b7 References checked&hellip;","og_url":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/","og_site_name":"RayPCB","article_published_time":"2024-01-02T06:46:13+00:00","article_modified_time":"2026-09-27T11:09:47+00:00","og_image":[{"width":1280,"height":530,"url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2024\/01\/bed-of-nails-test-fixture.jpg","type":"image\/jpeg"}],"author":"RAYPCB","twitter_card":"summary_large_image","twitter_misc":{"Written by":"RAYPCB","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/#article","isPartOf":{"@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/"},"author":{"name":"RAYPCB","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"headline":"What is Bed of Nails Test Fixture?","datePublished":"2024-01-02T06:46:13+00:00","dateModified":"2026-09-27T11:09:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/"},"wordCount":1132,"image":{"@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2024\/01\/bed-of-nails-test-fixture.jpg","articleSection":["Blogs"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/","url":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/","name":"What is Bed of Nails Test Fixture? - RayPCB","isPartOf":{"@id":"https:\/\/www.raypcb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/#primaryimage"},"image":{"@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2024\/01\/bed-of-nails-test-fixture.jpg","datePublished":"2024-01-02T06:46:13+00:00","dateModified":"2026-09-27T11:09:47+00:00","author":{"@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"breadcrumb":{"@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/#primaryimage","url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2024\/01\/bed-of-nails-test-fixture.jpg","contentUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2024\/01\/bed-of-nails-test-fixture.jpg","width":1280,"height":530},{"@type":"BreadcrumbList","@id":"https:\/\/www.raypcb.com\/bed-of-nails-test-fixture\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.raypcb.com\/"},{"@type":"ListItem","position":2,"name":"What is Bed of Nails Test Fixture?"}]},{"@type":"WebSite","@id":"https:\/\/www.raypcb.com\/#website","url":"https:\/\/www.raypcb.com\/","name":"RayPCB","description":"PCB manufacturer and PCB assembly","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.raypcb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f","name":"RAYPCB","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","caption":"RAYPCB"},"sameAs":["https:\/\/www.raypcb.com"],"url":"https:\/\/www.raypcb.com\/author\/admin\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2024\/01\/bed-of-nails-test-fixture.jpg","_links":{"self":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/29324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/comments?post=29324"}],"version-history":[{"count":1,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/29324\/revisions"}],"predecessor-version":[{"id":119577,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/29324\/revisions\/119577"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media\/29325"}],"wp:attachment":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media?parent=29324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/categories?post=29324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/tags?post=29324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}