{"id":6987,"date":"2019-10-13T00:54:09","date_gmt":"2019-10-13T00:54:09","guid":{"rendered":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/"},"modified":"2026-09-24T08:11:55","modified_gmt":"2026-09-24T08:11:55","slug":"comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards","status":"publish","type":"post","link":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/","title":{"rendered":"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing"},"content":{"rendered":"<div class=\"sp-page sp-page--compare\"><header class=\"sp-hero\"><div class=\"sp-wrap\"><p class=\"sp-breadcrumb\"><a href=\"https:\/\/www.raypcb.com\/pcb-manufacturing\/\">PCB Manufacturing<\/a> \/ <a href=\"https:\/\/www.raypcb.com\/hdi-pcb\/\">HDI PCB<\/a><\/p><div class=\"sp-hero-grid\"><div><p class=\"sp-kicker\">RAYPCB \u00b7 Route selection \u00b7 engineering comparison<\/p><h1>Blind vias vs buried vias: choose by the connection<\/h1><p class=\"sp-lead\">Compare physical access, <a href=\"https:\/\/www.raypcb.com\/pcb-routing\/\">routing<\/a>, fabrication sequence and verification. Classify a layer span and identify what to ask before choosing a via route.<\/p><div class=\"sp-actions\"><a class=\"sp-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Discuss your via strategy<\/a><a class=\"sp-btn sp-secondary\" href=\"#tool\">Open the worksheet<\/a><\/div><p class=\"sp-note\">Preliminary files and open process questions are welcome.<\/p><\/div><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/via-types-comparison.svg\" width=\"1100\" height=\"640\" loading=\"eager\" alt=\"Classify vias by physical access in the finished board\"><figcaption>Through vias reach both surfaces, <a href=\"https:\/\/www.raypcb.com\/blind-vias\/\">blind vias<\/a> reach one, and buried vias reach neither. A microvia describes a different construction category and is not a synonym for any one column.<\/figcaption><\/figure><\/div><\/div><\/header><nav class=\"sp-nav\" aria-label=\"On this page\"><div class=\"sp-wrap\"><a href=\"#answer\">Key answer<\/a><a href=\"#comparison\">Design reference<\/a><a href=\"#tool\">Worksheet<\/a><a href=\"#cost\">Cost &amp; scope<\/a><a href=\"#questions\">Questions<\/a><\/div><\/nav><section class=\"sp-section\" id=\"answer\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Blind vias and buried vias differ in physical access<\/h2><p>A blind via reaches an internal layer from one finished board surface. A buried via connects internal layers without opening on either finished surface. A through via reaches both surfaces. These terms describe physical extent and access; they do not, by themselves, select a drilling method, set the cost or establish reliability.<\/p><p>Choose between constructions by the connection you need and the manufacturing sequence that can produce it. A dense surface escape, an internal routing bottleneck and an unused through-hole stub are different design problems. They may lead to different solutions even when the board has the same number of layers.<\/p><p>This page is a route-selection guide. Once the decision is clearer, use the dedicated <a href=\"https:\/\/www.raypcb.com\/blind-vias\/\">blind-via construction page<\/a> or <a href=\"https:\/\/www.raypcb.com\/buried-vias-pcb\/\">buried-via subassembly page<\/a> for dimensional planning and an enquiry brief. The objective is to make a useful manufacturing decision, not to choose the most elaborate structure available.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"comparison\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Compare the features that change the design task<\/h2><div class=\"sp-table\" tabindex=\"0\" role=\"region\" aria-label=\"PCB process engineering comparison\"><table><thead><tr><th scope=\"col\">Question<\/th><th scope=\"col\">Blind via<\/th><th scope=\"col\">Buried via<\/th><th scope=\"col\">Through-via baseline<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Finished-surface access<\/th><td>One side<\/td><td>Neither side<\/td><td>Both sides<\/td><\/tr><tr><th scope=\"row\">Physical endpoints<\/th><td>Surface and internal layer<\/td><td>Two internal layers<\/td><td>Opposite finished surfaces<\/td><\/tr><tr><th scope=\"row\">Main planning task<\/th><td>Entry, target and accessible drilling route<\/td><td>Internal subassembly and enclosure sequence<\/td><td>Full-board hole and unused barrel review<\/td><\/tr><tr><th scope=\"row\">Routing opportunity<\/th><td>Avoid occupying some deeper layers<\/td><td>Keep layers outside the internal span free<\/td><td>Simpler baseline if space and performance allow<\/td><\/tr><tr><th scope=\"row\">Process question<\/th><td>How is the target reached and plated?<\/td><td>When is the internal pair formed and checked?<\/td><td>Does the conventional route meet requirements?<\/td><\/tr><tr><th scope=\"row\">Inspection question<\/th><td>Which hidden features need evidence?<\/td><td>What must be verified before enclosure?<\/td><td>What board and interconnect evidence is required?<\/td><\/tr><tr><th scope=\"row\">Cost comparison<\/th><td>Complete route, setup and verification<\/td><td>Complete subassembly sequence and verification<\/td><td>Complete baseline with any required extra work<\/td><\/tr><\/tbody><\/table><\/div><p>The table is deliberately not a ranking of \u201cgood, better, best.\u201d A construction is useful when it meets the product\u2019s electrical, mechanical and manufacturing requirements with an acceptable risk and cost. A simpler route can be the better engineering choice if the more complex route solves no demonstrated problem.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"tool\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Classify a physical layer span<\/h2><p>Enter the final layer count and the two physical endpoints. The classifier reports through, blind or buried based only on whether those endpoints reach the finished surfaces. It accepts either direction, rejects identical endpoints and does not infer a drilling technology or an electrical netlist.<\/p><p>Interactive engineering tool available on the website.<\/p><p>An eight-layer board with physical endpoints L1 and L3 has a blind span. L3 and L6 form a buried span. L1 and L8 form a through span. These examples explain the naming rule; they do not approve those spans for a proposed stackup or assign them a price.<\/p><p>The distinction matters when a through via connects a signal to an internal trace. Its electrical connection can leave on L3 even though its barrel continues to L8. The physical structure remains through, and the unused portion may require separate review. Entering only the active electrical layers into a physical classifier would misdescribe that hole.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"electrical\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Separate the connection list from the hole extent<\/h2><p>The netlist identifies intended electrical connections. The fabrication drawing identifies the actual physical barrel and its clearances. Both are needed. A through via can contact an internal signal layer, avoid other layers through antipads and continue beyond the active path. A topology label cannot tell you which intermediate copper features are connected or isolated.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/via-physical-electrical-span.svg\" width=\"1100\" height=\"640\" loading=\"lazy\" alt=\"Draw physical extent and electrical connection separately\"><figcaption>The physical span classifier does not infer every net connection. Stub review and route selection need the actual signal path and reference structure.<\/figcaption><\/figure><p>For a high-speed transition, review the barrel, lands, antipads, references and return path as a structure. A shorter physical span can reduce some unused geometry, but it does not automatically guarantee a particular impedance or loss result. The complete channel includes traces, connectors, packages and other transitions.<\/p><p>If the dominant issue is an unused through-hole stub, compare <a href=\"https:\/\/www.raypcb.com\/back-drill-pcb\/\">PCB backdrilling<\/a> with a different span or routing layer. Backdrilling removes a selected barrel portion with depth and radial constraints. It is not simply another name for a buried via, and it needs its own manufacturing definition.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"tasks\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Start with the constraint you can demonstrate<\/h2><p>Consider a fine-pitch device that cannot escape with the current through-via geometry. The next step is to compare land patterns, trace\/space, routing layers and surface-to-inner connections. A blind construction may open useful channels, but the process and landing geometry must be reviewed. Changing the package fanout or stackup may also solve the problem.<\/p><p>Consider a congested internal routing region with little reason for the connection to occupy outer layers. A buried pair may release space outside its span. Before selecting it, show that the required subassembly and other drill pairs form a coherent build. The benefit is local routing freedom, while the cost and verification apply to the complete board.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/via-selection-task-map.svg\" width=\"1100\" height=\"640\" loading=\"lazy\" alt=\"Make the via decision answer a real design constraint\"><figcaption>A route decision starts with a documented constraint and compares alternatives. No technology is automatically the most reliable or the lowest-cost choice for every board.<\/figcaption><\/figure><p>Consider a board that already routes and meets its electrical requirements with through vias. Adding blind or buried structures for appearance or perceived sophistication can introduce unnecessary constraints. Keep a documented baseline so that the proposed change has a measurable purpose: space recovered, a channel problem addressed, a board dimension reduced or another concrete benefit.<\/p><p>The comparison should make design effort visible too. A small fabrication saving can be outweighed by extensive rerouting, a new qualification campaign or a difficult late change. Conversely, a process increment can be justified if it produces a better total product outcome. Record the decision basis rather than treating the initial board quote as the only metric.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"sequence\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Read the stackup as a manufacturing plan<\/h2><p>Blind and buried structures depend on access at the relevant manufacturing stage. Ask when each pair is drilled, prepared, plated and treated, and when later layers enclose it. A final list of copper layers is not a complete sequence. The <a href=\"https:\/\/www.raypcb.com\/resources\/hdi-stackup-lamination\/\">HDI stackup and lamination guide<\/a> helps organize this information.<\/p><p>CAD software can represent layer spans and drill types, but representation is not process qualification. <a href=\"https:\/\/www.altium.com\/documentation\/altium-designer\/pcb\/blind-buried-micro-vias\" target=\"_blank\" rel=\"noopener\">Altium\u2019s via-definition documentation<\/a> provides a useful example of how design data describes these spans. Confirm the proposed route with the fabricator and check that exported files preserve the intended definitions.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/dense-multilayer-product.webp\" width=\"900\" height=\"540\" loading=\"lazy\" alt=\"Dense multilayer PCB product with fine-pitch land patterns\"><figcaption>Existing RAYPCB multilayer product photograph. Hidden drill spans and any backdrilling require the actual fabrication records.<\/figcaption><\/figure><p>Review all structures together. A board may combine through holes, blind features, buried pairs and via-in-pad locations. A change that looks small in one footprint may alter the build sequence or treatment requirements elsewhere. Keep the layer names, material definitions, drill map and fabrication notes synchronized as the design evolves.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"terminology\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Microvia and via-in-pad answer different questions<\/h2><p>Blind and buried describe finished-board access. Microvia describes a defined construction category under the applicable technical requirements. Via-in-pad describes the placement of a via within a component land. Stacked and staggered describe the arrangement of successive connections. These terms can apply together, but none should silently stand in for the others.<\/p><p>For example, saying \u201cBGA via in pad\u201d does not tell the fabricator whether the hole is a through structure or a blind structure, nor does it fully specify filling and capping. Use the <a href=\"https:\/\/www.raypcb.com\/bga-via-in-pad\/\">BGA via-in-pad design guide<\/a> for that package interface. Saying \u201cburied\u201d likewise does not establish whether a particular treatment or internal buildup has been qualified.<\/p><p>Keep the vocabulary tied to the drawing. Ask for the physical span, drilling method, dimensional convention, treatment and finished condition. This avoids discussions in which design, purchasing and manufacturing all use the same short term while imagining different structures.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"reliability\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Compare evidence, not a technology ranking<\/h2><p>There is no universal rule that buried vias are more reliable than blind vias, or that a visible opening is inherently a weakness. Materials, interfaces, geometry, processing and service conditions determine the relevant risks. Qualification evidence should represent the actual construction and the product\u2019s requirements.<\/p><p>For microvia-containing routes, <a href=\"https:\/\/www.ipc.org\/news-release\/ipc-issues-electronics-industry-warning-printed-board-microvia-reliability-high\" target=\"_blank\" rel=\"noopener\">IPC\u2019s published reliability warning<\/a> reinforces the need for careful evaluation of hidden structures. It does not provide a one-line ranking that can replace engineering review. Use the <a href=\"https:\/\/www.raypcb.com\/resources\/hdi-microvia-review\/\">HDI microvia review<\/a> to organize the questions and evidence.<\/p><figure><img src=\"https:\/\/www.raypcb.com\/wp-content\/plugins\/pcbsync-tools\/assets\/images\/special-process\/internal-via-microsection-example.webp\" width=\"1024\" height=\"542\" loading=\"lazy\" alt=\"Existing magnified section image of internal plated interconnections\"><figcaption>Existing illustrative section image from RAYPCB\u2019s buried-via page. No lot, scale or acceptance record is supplied; it is not qualification evidence.<\/figcaption><\/figure><p>Decide what each test establishes. Final continuity checks intended electrical connectivity at the time of test. A section shows selected internal geometry. A stress or reliability test evaluates a specified exposure and measurement. None should be casually described as proof of every aspect of quality. Keep the scope and construction identity with the result.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"cost\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Compare alternatives on the same commercial basis<\/h2><p>Cost depends on the full route: materials, board dimensions, layer structure, drilling operations, filling, lamination, registration, panel utilization and verification. Fixed percentages for \u201cblind\u201d or \u201cburied\u201d can conceal these differences. A lower layer count can still cost more if it introduces a demanding process sequence.<\/p><p>Prepare two controlled alternatives when a decision is open. Keep quantity, acceptable-board definition, finish, inspection and delivery scope consistent, then identify the structural changes. Separate setup and qualification from recurring fabrication. Ask what is excluded so that a price for an unverified prototype is not compared with a production-ready, fully documented build.<\/p><div class=\"sp-table\" tabindex=\"0\" role=\"region\" aria-label=\"PCB process engineering comparison\"><table><thead><tr><th scope=\"col\">Compare this<\/th><th scope=\"col\">Keep constant where possible<\/th><th scope=\"col\">Explain any change<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Bare-board scope<\/th><td>Quantity, outline, finish and acceptable delivery<\/td><td>Material or stackup alternative<\/td><\/tr><tr><th scope=\"row\">Engineering effort<\/th><td>Same release maturity<\/td><td>Rerouting or development work<\/td><\/tr><tr><th scope=\"row\">Verification<\/th><td>Product requirements and required evidence<\/td><td>New coupons, sections or qualification<\/td><\/tr><tr><th scope=\"row\">Assembly interface<\/th><td>Package and final land requirements<\/td><td>Changed pad, fill or cap condition<\/td><\/tr><tr><th scope=\"row\">Repeat production<\/th><td>Agreed revision and evidence<\/td><td>Approved substitutions or process changes<\/td><\/tr><\/tbody><\/table><\/div><p>Use the process-specific budget briefs on the blind-via and buried-via pages once an alternative is defined. They accept sourced allowances and can produce a technical request with costs blank. This comparison page avoids a generic price calculator because topology alone cannot supply a credible rate.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"decision\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Write a short decision record before committing<\/h2><p>Record the original constraint, baseline construction, alternatives considered, required evidence and the selected route. Include the reason alternatives were rejected. This record helps a later engineer distinguish a deliberate manufacturing requirement from a historical choice that may no longer be necessary after a redesign.<\/p><p>Ask the fabricator which dimensions and sequence details are still open. Approve any proposed change against both the electrical design and assembly interface. Keep the final stackup, drill map and fabrication notes together, and verify exported outputs rather than relying only on a CAD screenshot.<\/p><p>The <a href=\"https:\/\/www.raypcb.com\/hdi-pcb\/\">HDI PCB page<\/a> provides the closest manufacturing route for these structures. The broader <a href=\"https:\/\/www.raypcb.com\/pcb-manufacturing\/\">PCB manufacturing overview<\/a> covers the complete board service. A focused enquiry includes the design problem and the alternatives you can accept, allowing the discussion to move beyond a list of via names.<\/p><\/div><\/div><\/section><section class=\"sp-section\" id=\"questions\"><div class=\"sp-wrap\"><div class=\"sp-prose\"><h2>Questions that clarify the choice<\/h2><details><summary>Can one PCB contain through, blind and buried vias?<\/summary><p>Yes, a design can combine them, subject to a reviewed construction. Every physical span and treatment must fit the agreed manufacturing sequence. Combining labels in a CAD file is not sufficient evidence of feasibility.<\/p><\/details><details><summary>Is a via connected to an inner trace automatically blind?<\/summary><p>No. The barrel may continue through to the opposite surface. Classify the physical extent separately from the electrical connection, then review any unused span and the complete signal path.<\/p><\/details><details><summary>Should I choose the smallest possible via everywhere?<\/summary><p>No. Select geometry that meets the local routing or electrical task within a qualified process. Unnecessary feature reduction can increase manufacturing and verification demands without producing a useful product benefit.<\/p><\/details><details><summary>Which route should I send for quotation first?<\/summary><p>Send the simplest credible baseline and identify the constraint it cannot meet, if any. Include a controlled alternative when available. A manufacturer can give a more useful comparison when the task, stackup and acceptance scope are explicit.<\/p><\/details><\/div><\/div><\/section><section class=\"sp-section\" id=\"project-review\"><div class=\"sp-wrap\"><div class=\"sp-enquiry\"><h2>Discuss your via strategy<\/h2><p>Send the fabrication revision, stackup, quantity and the specific process question. Include connector or package requirements, mechanical drawings and the inspection evidence you need.<\/p><div class=\"sp-actions\"><a class=\"sp-btn\" href=\"https:\/\/www.raypcb.com\/contact\/\">Send your manufacturing requirements<\/a><a class=\"sp-btn sp-secondary\" href=\"mailto:sales@raypcb.com?subject=Blind%20Vias%20vs%20Buried%20Vias%20review\">Open an enquiry email<\/a><\/div><p class=\"sp-note\">Tool use is optional. Attach any downloaded brief manually; Contact does not automatically receive worksheet inputs. References reviewed September 2026. Illustrations are explanatory, and photographs are not process qualification records.<\/p><\/div><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>PCB Manufacturing \/ HDI PCBRAYPCB \u00b7 Route selection \u00b7 engineering comparisonBlind vias vs buried vias: choose by the connectionCompare physical access, routing, fabrication sequence and verification. Classify a layer span and identify what to ask before choosing a via route.Discuss your via strategyOpen the worksheetPreliminary&hellip;<\/p>\n","protected":false},"author":1,"featured_media":8271,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-6987","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing - RayPCB<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing - RayPCB\" \/>\n<meta property=\"og:description\" content=\"PCB Manufacturing \/ HDI PCBRAYPCB \u00b7 Route selection \u00b7 engineering comparisonBlind vias vs buried vias: choose by the connectionCompare physical access, routing, fabrication sequence and verification. Classify a layer span and identify what to ask before choosing a via route.Discuss your via strategyOpen the worksheetPreliminary&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/\" \/>\n<meta property=\"og:site_name\" content=\"RayPCB\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-13T00:54:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-24T08:11:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.raypcb.com\/wp-content\/uploads\/2019\/10\/2221_\u526f\u672c1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1362\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"RAYPCB\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"RAYPCB\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"36 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/\"},\"author\":{\"name\":\"RAYPCB\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"headline\":\"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing\",\"datePublished\":\"2019-10-13T00:54:09+00:00\",\"dateModified\":\"2026-09-24T08:11:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/\"},\"wordCount\":1417,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2019\\\/10\\\/2221_\u526f\u672c1.jpg\",\"articleSection\":[\"Blogs\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/\",\"name\":\"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing - RayPCB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2019\\\/10\\\/2221_\u526f\u672c1.jpg\",\"datePublished\":\"2019-10-13T00:54:09+00:00\",\"dateModified\":\"2026-09-24T08:11:55+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2019\\\/10\\\/2221_\u526f\u672c1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.raypcb.com\\\/wp-content\\\/uploads\\\/2019\\\/10\\\/2221_\u526f\u672c1.jpg\",\"width\":1920,\"height\":1362,\"caption\":\"blind via pcb and buried via pcb\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.raypcb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.raypcb.com\\\/\",\"name\":\"RayPCB\",\"description\":\"PCB manufacturer and PCB assembly\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.raypcb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.raypcb.com\\\/#\\\/schema\\\/person\\\/a3e536e8f139d147d3607efe2152c88f\",\"name\":\"RAYPCB\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g\",\"caption\":\"RAYPCB\"},\"sameAs\":[\"https:\\\/\\\/www.raypcb.com\"],\"url\":\"https:\\\/\\\/www.raypcb.com\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing - RayPCB","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/","og_locale":"en_US","og_type":"article","og_title":"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing - RayPCB","og_description":"PCB Manufacturing \/ HDI PCBRAYPCB \u00b7 Route selection \u00b7 engineering comparisonBlind vias vs buried vias: choose by the connectionCompare physical access, routing, fabrication sequence and verification. Classify a layer span and identify what to ask before choosing a via route.Discuss your via strategyOpen the worksheetPreliminary&hellip;","og_url":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/","og_site_name":"RayPCB","article_published_time":"2019-10-13T00:54:09+00:00","article_modified_time":"2026-09-24T08:11:55+00:00","og_image":[{"width":1920,"height":1362,"url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2019\/10\/2221_\u526f\u672c1.jpg","type":"image\/jpeg"}],"author":"RAYPCB","twitter_card":"summary_large_image","twitter_misc":{"Written by":"RAYPCB","Est. reading time":"36 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/#article","isPartOf":{"@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/"},"author":{"name":"RAYPCB","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"headline":"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing","datePublished":"2019-10-13T00:54:09+00:00","dateModified":"2026-09-24T08:11:55+00:00","mainEntityOfPage":{"@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/"},"wordCount":1417,"commentCount":0,"image":{"@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2019\/10\/2221_\u526f\u672c1.jpg","articleSection":["Blogs"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/","url":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/","name":"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing - RayPCB","isPartOf":{"@id":"https:\/\/www.raypcb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/#primaryimage"},"image":{"@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/#primaryimage"},"thumbnailUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2019\/10\/2221_\u526f\u672c1.jpg","datePublished":"2019-10-13T00:54:09+00:00","dateModified":"2026-09-24T08:11:55+00:00","author":{"@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f"},"breadcrumb":{"@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/#primaryimage","url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2019\/10\/2221_\u526f\u672c1.jpg","contentUrl":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2019\/10\/2221_\u526f\u672c1.jpg","width":1920,"height":1362,"caption":"blind via pcb and buried via pcb"},{"@type":"BreadcrumbList","@id":"https:\/\/www.raypcb.com\/comparison-between-blind-via-and-buried-via-in-manufacturing-of-printed-circuit-boards\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.raypcb.com\/"},{"@type":"ListItem","position":2,"name":"Blind Vias vs. Buried Vias: A Comparative Analysis for PCB design and Manufacturing"}]},{"@type":"WebSite","@id":"https:\/\/www.raypcb.com\/#website","url":"https:\/\/www.raypcb.com\/","name":"RayPCB","description":"PCB manufacturer and PCB assembly","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.raypcb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.raypcb.com\/#\/schema\/person\/a3e536e8f139d147d3607efe2152c88f","name":"RAYPCB","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ab28fde9e41b21b7378c7dfb18d6e7a339fd01473b7fddcfad0b3389cb5cd7a3?s=96&d=mm&r=g","caption":"RAYPCB"},"sameAs":["https:\/\/www.raypcb.com"],"url":"https:\/\/www.raypcb.com\/author\/admin\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/www.raypcb.com\/wp-content\/uploads\/2019\/10\/2221_\u526f\u672c1.jpg","_links":{"self":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/6987","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/comments?post=6987"}],"version-history":[{"count":1,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/6987\/revisions"}],"predecessor-version":[{"id":119385,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/posts\/6987\/revisions\/119385"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media\/8271"}],"wp:attachment":[{"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/media?parent=6987"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/categories?post=6987"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raypcb.com\/wp-json\/wp\/v2\/tags?post=6987"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}