RAYPCB · ENGINEERING GUIDE
Aluminum PCB Stackup: Copper, Dielectric, Metal Base and Finished Thickness
An aluminum PCB stackup should identify the circuit copper, electrical dielectric, metal base and any permanent outer layers. A statement such as 1.6 mm aluminum PCB does not reveal whether that dimension refers to the base alone or the finished construction.
This page focuses on the drawing and layer schedule for a common single-circuit IMS board. The thickness worksheet adds entered finished values with explicit units. For thermal-performance factors, use aluminum PCB conductivity; for complex interconnection, use multilayer metal-core design.

Draw the electrical function of each layer
The copper carries the circuit. The dielectric separates it electrically from the conductive metal base. The base provides mechanical support and part of the heat path. Mask and finish apply to defined outer features and should not be confused with the primary dielectric.
Show which surface contacts the housing and whether the base has a defined electrical potential. A stack picture with colored rectangles is useful only when each rectangle is tied to a material, thickness and function in the released construction.
Define finished versus supplied thickness
Record the finished dielectric target and its tolerance, along with the copper requirement and base thickness. Starting film or foil values can differ from finished local dimensions after processing. Avoid mixing a nominal supplied value for one layer with a minimum finished value for another without explanation.
The worksheet is simple bookkeeping. For 70 µm copper, 100 µm dielectric, 1.5 mm base and 20 µm permanent outer allowance, the sum is 1.69 mm. The result is not a guaranteed board thickness or a substitute for a measured tolerance stack.
| Review item | What to establish |
|---|---|
| Layer function | Circuit, electrical dielectric, conductive base and outer treatments. |
| Thickness | Finished values, units, local regions and tolerance definitions. |
| Holes | Mounting versus electrical structures and base isolation. |
| Release | One matching stack, artwork, material schedule and inspection scope. |
Single-circuit IMS thickness sum
Single-circuit IMS thickness sum
Use the current inputs and keep the assumptions
Start with the physical boundary named above the inputs. Enter your own values, or select Load example to explore the labeled teaching case. Example mode stays visible after edits so an illustrative calculation is not mistaken for measured project data. Clear for my inputs removes the sample values and starts a separate record.
Generate the result after completing every field. Changing any input invalidates the previous output and disables its download until you calculate again. Read the limitations below the numbers: a geometric or arithmetic result does not qualify a material, approve a circuit or establish manufacturing capability.
Download the current result if it helps the review. The text file contains inputs, outputs, assumptions and the tool version. It stays on your device; attach it manually to an enquiry if useful. No CAD is uploaded or interpreted, and nothing is automatically inserted into the Contact form. You can request an engineering review without completing this tool.
| Input | What to establish before using it |
|---|---|
| Review reference | Use a nonconfidential scope or revision. |
| Finished copper · µm | One circuit layer; other constructions require a separate drawing. |
| Finished insulation · µm | One permanent dielectric between copper and base. |
| Metal-base thickness · mm | Nominal finished base thickness. |
| Mask / other permanent outer allowance · µm | Bookkeeping only; local mask and exposed pads can differ. |
Optional cost comparison from your own allowances
Use a quotation or a clearly labeled internal assumption for each input. Keep the quantity, construction and inspection scope the same when comparing alternatives. This uncalibrated planning model adds entered values; it contains no current market rates and does not issue a RAYPCB quotation. You can contact the team without completing it.
Entered material and process budget
Treat local surfaces separately
An exposed solder pad, masked copper region and routed edge do not necessarily have identical local height or surface composition. If mechanical contact or component fit depends on a particular region, dimension that region explicitly. Do not rely on one global sum to describe every point on the board.
Specify the datum used for assembly and inspection. A base surface may serve as a useful mechanical reference, but the drawing must say so. Include any machining, recesses or surface treatments that affect mounting.

Choose the dielectric with two requirements
Thermal transfer and electrical insulation must be reviewed together. Reducing thickness may improve a simple thermal-resistance calculation while changing electrical stress and process sensitivity. Grade, thickness, test method and construction evidence belong in the same material schedule.
Use high-conductivity materials for a controlled layer comparison and high-voltage design when the board participates in an insulation barrier. This stack worksheet does not calculate working voltage, creepage, clearance or dielectric qualification.
Resolve holes and edges
State whether holes are mounting holes, electrical connections or special isolated structures. A common single-circuit IMS board must not be assumed to support a conventional multilayer plated-through-hole construction. Conductive metal near a hole or edge needs explicit design and process treatment.
Keep copper-to-edge and hole requirements tied to the reviewed design. Burrs, routed features and mounting hardware can influence the completed assembly. The manufacturer should review the actual outline and hole schedule before the stack is treated as releasable.
Include copper pattern and assembly
Copper weight affects current paths, etching and soldering. Dense fine features and large high-current areas can impose different priorities. Provide the artwork with the stack proposal so the material review is not detached from the pattern that must be manufactured.
For populated boards, state component types, soldering process and critical thermal interfaces. An LED board with large heat-transfer pads may need a different assembly discussion from a simple connector board using the same nominal base thickness.
Compare quotations on the same construction
Use the exact grade, thickness schedule, copper, finish, outline, quantity and verification scope. Ask the supplier to identify substitutions or optional constructions separately. A cheaper quote based on another dielectric or base is an alternative to review, not automatically the same board.
The optional cost worksheet uses entered allowances only. It does not know material stock, panel utilization or yield. Keep those assumptions in the quotation review, and distinguish prototype setup from costs expected to recur on subsequent orders.
Release one controlled stack
Provide a readable cross-section and table that agree with the fabrication notes, BOM and mechanical drawing. Identify revision, tolerances, material approvals and inspection requirements. Record any accepted alternative rather than allowing informal substitutions to accumulate across email threads.
For a quotation, continue to aluminum PCB manufacturing. The useful enquiry includes the complete stack and the unresolved requirement. Customers can contact RAYPCB directly; completing either worksheet is optional.
Coordinate the board stack with the installed heat path
Prepare one cross-section that includes copper, dielectric, metal, mounting interface and the relevant housing surface. Mark the electrical potential of conductive regions and the intended heat-flow route. This drawing exposes assumptions that a board-thickness callout or a conductivity value cannot describe alone.
Add actual hole and outline features. Explain which holes provide electrical connection, which are mechanical and which require isolation from metal. Keep tolerances and the intended inspection boundary on the same revision. A simple IMS coupon is not automatically representative of a complex multilayer or machined construction.
Share the assembly and mounting conditions before final material selection. Heat transfer, soldering, flatness, fastening and insulation can pull the design in different directions. A useful manufacturing response identifies those tradeoffs and the evidence needed for the particular construction, without promising that one generic stack suits every product.
Before release, place the chosen requirement, the proposed construction and the evidence in one review record. Separate measured values from supplier nominal data and from your own assumptions. If a value is unknown, identify who will obtain it and what decision depends on it. An empty field is more honest and more useful than an invented typical figure.
During an A/B comparison, change one relevant variable where possible. Preserve the original inputs and the reason for the change. If several things change together, describe the result as a comparison between complete configurations. Do not attribute the entire difference to one material or geometry feature without supporting evidence.
For a repeat order, confirm that the relevant drawing, material and process revisions still match the accepted configuration. Record alternatives explicitly. This small discipline helps purchasing avoid an apparently equivalent substitution that changes the engineering basis of the original decision.
Standards, source context and limits
Use the actual applicable document and edition for contractual requirements. Public technical resources help explain methods, but do not reproduce every condition in a licensed standard or qualify a particular RAYPCB construction. Retain exact grades and test boundaries when reading supplier data.
The numeric examples on this page are illustrative inputs unless specifically identified otherwise. Archive photographs show relevant physical context; they are not current equipment, material-grade or inspection evidence. Original drawings explain the models and are not production drawings. Ask for the evidence and acceptance scope needed for your project rather than inferring approval from an image or calculator result.
For fabrication scope and the agreed construction requirements, see PCB manufacturing.