RAYPCB · Surface engineering

Gold Plating PCB: Hard Gold, Soft Gold, Thickness & Cost

Gold plating on a PCB can serve wear contacts, wire-bond pads or solderable interfaces, but those functions require different deposits. This guide focuses on specifying electrolytic hard or soft gold, controlling selective area and thickness, and understanding the resulting cost.

Send preliminary files or an existing fabrication note. Identify the finish decision you need help resolving.

Original RAYPCB gold-finger photograph: define the mating region and selective plating requirement on the drawing
Original RAYPCB gold-finger photograph: define the mating region and selective plating requirement on the drawing.

A clear starting point for the finish decision

gold plating PCB — specification quick reference
Specification itemHow to use it
Finish systemElectrolytic gold
Standards mapInvoked IPC board performance standard plus drawing; ASTM B488 where applicable
Thickness planningSpecify gold type, purity, hardness, nickel underplate and local minimum thickness. Example 30 µin = 0.762 µm; this is not a universal requirement.
Main cost driversSelective plated area × thickness, plus masking, electrical access, setup and inspection.
Acceptance basisOrdered revision, drawing, measurement, sampling and application-specific evidence.

Thickness examples and selection guidance are not a complete IPC acceptance specification. State the contracted revision, measurement basis, sampling and application requirements on the order.

Shortlist by the interface your product needs

Choose the primary interface and the constraints that matter. The selector explains candidates and open questions; it does not rank finishes by a fabricated quality score. You can open the relevant finish page or go directly to an enquiry.

RAYPCB ENGINEERING

PCB Surface Finish Selector

Surface Finish
Loading PCB Surface Finish Selector…
Using this tool & sharing results

Use the stated units, input limits and model assumptions. Results support an engineering discussion; they do not approve a design, process or production order.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

Separate hard gold, soft gold and immersion gold

Hard gold is an electrodeposited gold alloy intended for appropriate contact-wear applications. Soft gold is selected where purity and the qualified bonding or other interface requirement call for a softer deposit. ENIG is a different finish system: a thin immersion-gold cap over electroless nickel. These are not interchangeable merely because they all look gold-coloured.

A connector specification may identify purity, hardness, underplate, thickness, porosity, mating geometry and electrical performance. A wire-bond specification can impose a different set of requirements. Solder pads have their own metallurgy and assembly concerns. Start by classifying every relevant area on the board before choosing a plating note.

The scope of ASTM B488 concerns electrodeposited engineering gold and excludes immersion and autocatalytic gold coatings. Use the applicable purchased revision when it is invoked; the linked older scope is useful for the distinction, not for current acceptance clauses. The ASTM work-item listing identifies B488-18(2025). Neither reference makes every gold finish suitable for every PCB interface.

For an ambiguous gold-finish request, use the immersion gold versus electroplated gold functional comparison to separate solder lands, bond lands and wearing contacts before selecting the deposit.

gold plating PCB layer structure
Finish construction is shown schematically. Layer heights are exaggerated; this is not a production microsection.

Selective gold area and ideal deposited mass

Calculate rectangular contact area and the ideal gold mass using 19.32 g/cm³. Example: 40 contacts × 8 mm × 2 mm × 2 faces at 30 µin produces about 0.01884 g of ideal deposited gold per board. This is not a process price or a wear-life prediction.

RAYPCB ENGINEERING

Surface Finish Engineering Workbench

Surface Finish
Loading Surface Finish Engineering Workbench…
Using this tool & sharing results

Use the stated units, input limits and model assumptions. Results support an engineering discussion; they do not approve a design, process or production order.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

From surface preparation to a controlled release

Follow the sequence below. The optional step player is a conceptual explanation, not factory footage or a production recipe.

  1. Map plated areas

    Separate wear contacts, bonding pads and solder pads on the controlled fabrication drawing.

  2. Plan electrical access

    Electroplating needs a current path; review temporary buses, tie bars, masking and their later removal.

  3. Prepare and plate nickel

    Clean the copper and deposit the specified barrier with edge coverage and local minima under control.

  4. Electroplate gold

    Use the agreed hard or soft gold chemistry. Current distribution changes with geometry and rack loading.

  5. Remove temporary features

    Strip masks and remove process connections without leaving unintended shorts or damaging the contact region.

  6. Inspect contact function

    Check local thickness, adhesion, porosity where specified, surface quality, mating geometry and contact performance.

gold plating PCB process flow
The sequence explains process responsibilities. Actual chemistry, settings and acceptance follow the qualified manufacturing route.

Why selective plating is often the important design decision

A product may need durable gold only on the mating contacts. Applying the same deposit to every exposed feature can add unnecessary metal area, mask complexity or assembly constraints. A selective drawing should identify the functional contact zone, adjacent transition, keepouts and any separate solderable finish used elsewhere.

Electroplating requires an electrical path during processing. Temporary buses or tie bars may be needed, and their removal must not leave unintended connections or compromise the finished edge. Isolated bond pads and internal features can be difficult to reach with a plating current path. Discuss this while the panel and artwork are still being planned.

Current density is not perfectly uniform over all features. Edges, corners, racks, panel loading and local geometry can change deposition. A local minimum on a contact can therefore be more important than the average on a convenient large coupon. A well-defined inspection plan connects the plating setup to the surface that will actually touch the mating connector.

Thickness: specify the interface and the unit

Gold thickness is often quoted in microinches and micrometres. The conversion is exact: 1 µin equals 0.0254 µm. Thus 10, 20, 30 and 50 µin correspond to 0.254, 0.508, 0.762 and 1.270 µm. These are conversions, not four universal quality grades or an instruction to choose the thickest value.

The appropriate thickness depends on the deposit, mating system, contact force, wear path, environment and qualification. A connector drawing may require a local minimum in the functional contact area, with a separate nickel underplate requirement. Specify where the requirement applies and how it is measured. Do not assume gold thickness alone predicts insertion-cycle life.

Avoid ambiguous shorthand such as “30u gold.” It can be misread and says nothing about hard versus soft gold. Write the full unit, metal type, measurement area and acceptance basis. Keep the nickel barrier separate in the requirement and inspection report. If a customer drawing uses a different convention, resolve it rather than silently converting a nominal value into a minimum.

Original RAYPCB gold-plated circular-contact panel
Original RAYPCB gold-plated circular-contact panel. Contact function and local thickness require a controlled specification.

Edge contacts: geometry and mechanics remain essential

For a card-edge interface, define the finished board thickness, contact dimensions, spacing, edge position and any required bevel. The mating connector sets the mechanical reference. A familiar bevel angle or contact length from another board should not become the default without checking that connector.

Keep the functional mating region free of features that the connector specification does not allow. Discuss soldermask proximity, vias, edge finish and any routing or plating remnants. If fingers have different lengths for sequencing, preserve those lengths in the finished outline and inspection plan. Electrical test does not verify every mechanical aspect of a mating contact.

Wear performance should be evaluated using the actual mating system and environmental conditions. Contact force, wiping distance, contamination and counterpart finish can affect results. A generic “thousands of insertions” claim without those conditions is not useful evidence. For construction details beyond the finish itself, continue to the gold finger PCB design and manufacturing page.

gold plating PCB design principle
Original engineering illustration of the decision explained in this section. No measured reliability or ageing result is implied.

Do not assume a wear finish is automatically a solder finish

A deposit selected for contact wear may not be the right surface for soldering or wire bonding. The gold alloy, thickness and total gold introduced into a solder joint need attention. If hard-gold regions extend onto solder lands, review the assembly consequences rather than treating the extra coverage as harmless protection.

A mixed-function board can use selective finishes when the manufacturing route supports them. Mark the regions clearly and ask how the process sequence avoids unwanted attack, contamination or an unprotected transition. The drawing should show both the functional finish and its boundary, not leave the operator to infer it from component placement.

For a general flat solderable surface, compare ENIG. For a board combining qualified bonding and soldering, examine ENEPIG. These links are alternatives for distinct functions, not a price ladder. The most expensive metal stack is not necessarily the most appropriate interface for the product.

Area and thickness explain metal demand, not the whole price

The engineering calculator estimates ideal deposited gold mass from plated area and thickness using bulk gold density. For rectangular contacts, area equals length multiplied by width, contact count and number of plated faces. With area in square millimetres and thickness in micrometres, ideal mass in grams is area × thickness × 0.00001932.

For example, forty 2 mm × 8 mm contacts on two faces have 1,280 mm² of plated area. At 0.762 µm, the ideal gold mass is about 0.01884 g per board. This simple model excludes deposit alloy differences, overplating, current distribution, process losses, nickel, baths, masking and setup. It is useful for understanding sensitivity, not calculating a supplier invoice from a bullion price.

Halving unnecessary plated area halves ideal metal volume at equal thickness. Whether the quotation falls by the same proportion depends on setup and processing. Use the separate budget comparison for entered finish allowances and ask for a file-based quote. Do not reduce functional contact area or specified minimum thickness solely to lower the calculator result.

Original RAYPCB gold-plated contact boards
Original RAYPCB gold-plated contact boards. The image illustrates selective area; it is not evidence of a particular wear rating.

Release a complete gold-plating request

Provide the controlled artwork, board outline and explicit plating map. Name the hard or soft gold requirement, the nickel underplate, local minimum or nominal basis, required standard revision and the functional area. Add the mating connector or bonding process information needed to interpret those values.

Specify inspection evidence according to the application: metal-layer thickness, sampling locations, adhesion, porosity where required, contact resistance or bond tests. The exact set depends on the contract. A colour photograph cannot prove the gold alloy, hardness or thickness, and a generic certificate without a lot reference does not identify the delivered board.

For a gold-plating quotation, include quantity and whether the first order is for qualification or repeat production. Flag open decisions such as bevel, selective boundaries or plating access. The response can then distinguish engineering work from recurring manufacturing cost. Keep the final agreed note with the board revision so that repeat purchases preserve the intended contact interface.

Compare finish allowances and prepare a useful RFQ

Use the same quantity, currency and included scope for both options. Enter a bare-board allowance only if you want it included; leaving it blank produces a finish-only comparison. Setup and inspection or packing are lot charges, while the finish allowance is per board. Enter zero only for a confirmed zero or already-included item.

The comparison exposes the arithmetic behind your inputs. It does not estimate a supplier tariff, promise a yield saving or approve a complex selective-finish route. Changing quantity or finish choice clears the affected allowances so an old assumption is not silently carried into a new scenario. Exact quotes require fabrication files and an agreed finish specification.

RAYPCB ENGINEERING

Surface Finish Cost Comparison

Surface Finish
Loading Surface Finish Cost Comparison…
Using this tool & sharing results

Budget outputs are planning scenarios. Check the included costs and rate assumptions; a confirmed quotation requires a review of your files and scope.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

Keep the finish requirement with the design revision

gold plating PCB inspection brief
Use the drawing to state requirements and traceable reports to establish the ordered evidence.
Finish RFQ handoff checklist
Include in the enquiryWhy it matters
Fabrication files, revision and quantityKeeps the quotation tied to the correct geometry and build.
Finish system and selective area mapSeparates solder, bond and contact functions.
Standard revision, metal / film requirement and methodMakes the acceptance requirement interpretable.
Assembly sequence, storage and service exposureIdentifies the condition in which the interface must function.
Required reports and open decisionsDistinguishes supplied evidence from qualification still needed.

Use the tool download or email draft to carry the current inputs into a discussion. Attach your fabrication data separately. The Contact button opens the enquiry page; it does not automatically transfer calculator parameters or upload files. Preliminary information is welcome when the finish still needs to be selected.

Questions engineers and buyers ask

Does 30 microinch mean 30 micrometres?

No. 30 µin equals 0.762 µm. Always state the complete unit on drawings and inspection reports.

Can gold mass determine the PCB price?

No. Ideal deposited mass omits processing, setup, nickel, masking, testing and losses. It supports sensitivity analysis only.

Is every gold finger hard gold?

Do not infer chemistry from the feature name. The contact drawing must specify the required deposit and performance.

Can isolated pads be electroplated without a current path?

Electrolytic deposition needs electrical access. Review temporary process connections or another qualified finish route before release.

Continue with a related finish decision

Standards and original technical references

These references support scope and engineering context. Public previews do not contain every licensed acceptance clause. Use the ordered standard revision, agreed drawing and qualified supplier process for production acceptance.