RAYPCB · Layer access · construction planner
Blind vias: connect a surface to the right inner layer
Plan blind-via layer spans, drilling geometry and landing requirements. Compare laser and mechanical routes using a documented stackup.
Preliminary files and open process questions are welcome.
What is a blind via in a PCB?
A blind via connects one finished PCB surface to an internal layer without opening on the opposite surface. The name describes physical access. It does not automatically mean laser drilling, a particular diameter, one lamination cycle or a guaranteed improvement in signal integrity. A useful specification identifies the entry side, target layer, drilling construction and required finished condition.
Blind vias can help a dense component escape or avoid an unnecessary full-board barrel, but the complete stackup must support the proposed route. Discuss the required spans before routing the entire board. A via that can be drawn in CAD is not necessarily part of an efficient or qualified manufacturing sequence.
Use this page to prepare a blind-via construction. If the connection lies entirely between internal layers, use the buried-via manufacturing guide. If the main question is which structure to choose, start with the blind-versus-buried comparison before entering detailed dimensions.
The layer span is only the first decision
A physical span such as L1 to L2 does not describe all the work required to manufacture it. State the dielectric and copper structure being drilled, the intended drilling method, landing geometry, preparation, plating and any filling. For a bottom-side entry, label the physical direction explicitly instead of relying on an automatically mirrored picture.
| Route under review | Information to establish | What not to assume |
|---|---|---|
| Laser-drilled blind structure | Dielectric thickness, material, opening and landing geometry | Every material and span uses the same laser process |
| Mechanically drilled blind structure | Depth control, tool geometry, landing and plating access | A through-hole drill rule applies unchanged |
| Sequential construction | Accessible subassembly and build order | Final layer count equals lamination count |
| Stacked connection strategy | Interfaces, fill and qualified sequence | Shorter routing automatically means greater reliability |
| Staggered connection strategy | Offset lands and routing space | Staggering removes every process constraint |
Altium’s via-definition documentation illustrates how layer spans and via types are represented in a design system. The CAD definition is a communication aid; manufacturing support for the proposed construction still needs to be confirmed with the fabricator.
Check the span and the stated drilling geometry
The worksheet accepts a total finished layer count, an external entry layer, an internal target and the actual maximum drilling depth and minimum drilling diameter. It rejects a span that is not blind by the entered topology. It reports layer intervals and a geometric depth-to-diameter ratio without assigning a universal capability threshold.
Blind Via Span and Geometry
For example, entering L1 to L2 in an eight-layer board with a 0.10 mm drilling depth and 0.10 mm diameter produces a ratio of 1.0. That arithmetic does not approve the structure or make it compliant with an unspecified standard. A second example with the same layer names but a different dielectric thickness can have a different process requirement. Layer count is not a substitute for the actual drilled depth.
Record the diameter convention. A tapered laser opening has different dimensions at different depths, while a mechanical tool and finished plated hole are also different quantities. The worksheet uses the diameter you identify for the review; it does not infer taper, copper thickness or finished opening. Keep those details in the drawing and the process discussion.
Review the landing, clearance and target condition
The via must arrive at the intended copper feature despite drilling and layer-registration variation. Review landing dimensions, the target copper condition and clearances to unrelated conductors. A nominal center point landing on a nominal pad does not show the worst-case remaining copper. Ask which dimensions are controlled before and after processing.
On intervening layers or near neighboring features, define the required non-connections as clearly as the intended connection. A route may be electrically correct in the CAD netlist but geometrically incompatible with the proposed drill or plating process. Review the maximum feature envelope and fabrication tolerances, not only the design-rule minimums used during routing.

If the blind via sits under a component land, the assembly surface becomes another requirement. The BGA via-in-pad guide examines that interface. Blind describes where a hole opens; via-in-pad describes where it is placed. A single feature can be both, and its fill or cap requirement must be reviewed accordingly.
Make the build sequence visible before release
List every requested drill pair and identify when it becomes accessible. Some designs combine through holes, blind structures and internal connections. Each operation must fit into a coherent manufacturing route. Adding one more span late in routing can change more than a drill file if it requires a different subassembly or another build stage.
The HDI stackup and lamination guide provides a place to organize the full sequence. Use that record to identify materials, copper layers, dielectric thicknesses and drilling stages. Keep final electrical layer names traceable throughout, even when the fabricator groups layers into subassemblies for production.
Review copper balance and the effect of repeated processing on the actual construction. Do not assume that a change in one outer dielectric leaves all impedance, registration or assembly requirements unchanged. The manufacturing sequence and the electrical stackup describe the same board from different viewpoints; they should be reconciled rather than maintained as disconnected documents.
Ask for evidence for the actual structure
Reliability depends on geometry, materials, processing and the service environment. A catalog statement that a factory can produce blind vias is not qualification evidence for every stacked or staggered construction. Identify the interfaces that matter and agree how the proposed build is demonstrated to meet the product requirements.
IPC’s microvia reliability warning is a reason to treat microvia qualification carefully, especially where hidden interfaces are critical. It should not be turned into a blanket claim that all blind vias are unreliable or that one layout arrangement always solves the problem.
Use the HDI microvia review checklist when the chosen process includes microvias. State which coupons or product features represent the construction, which stress and measurement methods apply, and how evidence is tied to the material and process revision. A final continuity test and a reliability evaluation answer different questions.

Photographs of a finished board show routing context but cannot establish the internal via route. Ask for the agreed construction records and inspection evidence when those properties matter. Avoid judging a buried interface by the color or neatness of the external board alone.
Use blind vias where they solve a defined constraint
A dense BGA may need a short surface-to-inner connection to open routing channels. In that case, compare the package escape, land size, reference continuity and available routing layers together. A smaller blind feature can create local space while shifting congestion elsewhere, so check the full escape region rather than one successful connection.
For a high-speed signal, reducing an unused barrel may be useful, but the complete transition still needs electrical review. Pads, antipads, references and neighboring conductors remain part of the structure. A blind via does not automatically produce a chosen impedance or a guaranteed bandwidth. If the problem is a long unused through-hole stub, backdrilling may be another route to compare.
For power or thermal paths, review current distribution and heat flow with the actual plated or filled construction. Counting vias without defining their dimensions and material properties can obscure the design question. The fabrication request should make clear whether the feature primarily serves signal escape, electrical power, heat transfer or more than one task.
Compare complete constructions rather than a via surcharge
Blind-via cost can depend on drilling method, depth, material, feature density, plating or filling, registration, sequence and verification. A new span can introduce another setup or build stage; increasing the count within an existing qualified operation may have a different impact. Therefore a universal per-via price or percentage markup can mislead a design decision.
Ask for alternatives at the stackup level. A slightly different layer assignment, package escape or board area may simplify the route. Compare those options against routing effort, performance, board cost and qualification needs. Do not call an option cheaper solely because it has fewer finished copper layers if it requires a more complicated process.
Blind Vias Budget and RFQ Brief
Use the budget brief for a defined route and quantity. Its amounts come from your entered source, with separate setup and verification allowances. It has no built-in market rates. With costs blank, it becomes an RFQ scope document. Include the drill pairs and actual geometry; the engineering worksheet does not automatically populate or approve the commercial scope.
Send a layer map that engineering can act on
Provide fabrication outputs, the stackup, drill-pair map, via dimensions, material requirements, fill or cap instructions, quantity and acceptance expectations. Highlight the routing constraint that motivates the blind structure. If several options are acceptable, identify them before the artwork is fully locked so that a useful manufacturing alternative can be evaluated.
Review the exported outputs, not just the CAD display. Confirm layer names, entry direction, drill classifications and the link between symbols and dimensions. A designer’s screen can look correct while an incomplete export omits the intended span. Keep approved clarifications in the released package so they remain available for repeat production.
For the overall service route, visit HDI PCB manufacturing and the broader PCB manufacturing overview. The enquiry should identify the actual structure and open questions, allowing a process review without claiming that a simple online ratio has already established manufacturability.
Blind-via questions before fabrication
Are all blind vias laser microvias?
No. Blind describes access from one finished surface to an internal layer. The drilling method and construction category need separate definition. Use the applicable standard and qualified process for a microvia requirement rather than applying the label to every blind hole.
Can a blind via connect more than one layer interval?
A proposed span needs review against the actual construction and drilling route. Do not assume that a span shown in CAD is supported merely because another adjacent-layer span is available. Supply the complete stackup and target geometry.
Does a ratio of one mean the design is approved?
No. The worksheet reports an entered geometric quotient. Material, taper, landing, preparation, plating, tolerances and reliability remain separate requirements. A ratio without a defined measurement convention is especially easy to misinterpret.
Should blind vias be used on every dense board?
Use them when the design task justifies the manufacturing route. A through-hole baseline, revised fanout or another stackup may already meet the requirement. Compare practical alternatives before making the structure a fixed purchasing constraint.
Review your blind-via construction
Send the fabrication revision, stackup, quantity and the specific process question. Include connector or package requirements, mechanical drawings and the inspection evidence you need.
Tool use is optional. Attach any downloaded brief manually; Contact does not automatically receive worksheet inputs. References reviewed September 2026. Illustrations are explanatory, and photographs are not process qualification records.