RAYPCB · ENGINEERING GUIDE
PCBA Conformal Coating: Specify Cleaning, Masking, Cure and Inspection
PCBA conformal coating applies a protective polymer film to selected areas of an assembled circuit board. The process includes surface preparation, controlled application, cure and verification. A resin name alone does not define a manufacturable coating requirement or demonstrate that the assembly is protected against its actual environment.
This page owns the production workflow. Material selection and the decision whether to coat have separate guides. The volume worksheet estimates ideal dry-film volume from entered area and thickness; it does not predict material consumption or recommend a film thickness.

Release a coating drawing before application
Identify coated areas, no-coat zones, connector interfaces, test access, sensors, switches and mechanical mating surfaces. Define the applicable side and revision. An instruction to coat everything can unintentionally disable a connector or cover a surface that needs later contact.
Review whether coating occurs before or after programming, test and mechanical operations. The coating decision guide addresses the product need; the released drawing turns that decision into an executable manufacturing scope.
Establish cleanliness and surface compatibility
Residues, moisture and handling contamination can affect adhesion and electrical behavior. The cleaning process must be compatible with the assembly materials and selected coating. A no-clean flux designation does not independently establish suitability for every coated product.
Use the PCB cleaning guide to define the actual removal, rinse and drying route when required. Verify the resulting surface condition with methods appropriate to the product rather than relying only on visual appearance.
| Review item | What to establish |
|---|---|
| Drawing | Identify coat and no-coat areas by revision. |
| Surface | Verify cleanliness and material compatibility. |
| Film | Separate dry thickness, wet application and purchased volume. |
| Release | Document cure, coverage and required post-coat tests. |
Ideal dry-film volume
Ideal dry-film volume
Use the current inputs and keep the assumptions
Choose the engineering question before entering numbers. Fields begin blank. Load example fills teaching values so you can understand the model; those values are not recommended dimensions, process settings or market prices. The example label remains visible after edits. Reset before preparing a record based entirely on your own project data.
Use the displayed units and keep a reference for each input. Counts must describe the same scope, and measurements must share the declared conditions. A threshold entered by you remains your supplied review condition. The website does not turn it into an IPC limit or an approved product requirement. If the necessary value is unknown, obtain the evidence rather than replacing it with an attractive assumption.
Read the result and its limitations together. An access fraction is not fault coverage, a cost allowance is not a quotation, and a completed evidence checklist is not a safety or quality approval. Negative margins remain visible where the model permits them. They identify a conflict in the entered scenario rather than silently adjusting the result.
Changing an input invalidates the result and disables its download until you run the tool again. The text record contains the inputs, result and limitations. Processing stays in your browser; no CAD files, instruments or certificates are read. No data is automatically transferred to the enquiry form. Download and attach the record manually if useful, or contact RAYPCB directly without completing the tool.
| Input | What to establish before using it |
|---|---|
| Review reference | Use a nonconfidential revision or scope reference. |
| Total area to receive film · cm² | Include all surfaces you intend to model; a flat board area can underestimate assembly area. |
| Entered dry-film thickness · μm | Your requirement; no recommended thickness is supplied. |
| Assemblies | Whole count; same area and thickness assumption. |
Optional cost comparison from your own allowances
Use a quotation or a clearly labeled internal assumption for each input. Keep the quantity, construction and inspection scope the same when comparing alternatives. This uncalibrated planning model adds entered values; it contains no current market rates and does not issue a RAYPCB quotation. You can contact the team without completing it.
Entered process and verification budget
Control application with the exact material
Record product identity, batch, shelf life, storage, mixing where applicable and the relevant technical data. Viscosity, solids content, application method and board geometry influence film formation. Do not transfer a setting from another resin simply because both are described as conformal coatings.
Selective dispensing, spraying, brushing and dipping have different access and masking implications. The coating-machine guide focuses on repeatable application controls and program validation.

Distinguish dry film from wet consumption
For a flat area, ideal dry-film volume equals area multiplied by dry thickness. The worksheet converts square centimeters and micrometers to milliliters. Real assemblies add component surfaces and irregular geometry that must be included in a defensible area estimate.
Purchased material consumption also depends on solids content, transfer efficiency, purge, overspray and waste. The tool does not infer these from the resin name. Use measured process data for costing and verify thickness by the agreed method and locations.
Verify cure and coverage separately
A tack-free surface does not automatically establish complete cure. Follow the exact material's documented conditions and verify the relevant state on the actual assembly. Shadowed regions, thickness and local geometry can influence the process.
Fluorescent inspection can help reveal coverage when the material supports it, but brightness alone does not prove thickness, cure or adhesion. Keep inspection criteria and any required electrical verification explicit.
Plan rework and continued access
Coating changes the effort needed to reach components and test points. Define approved removal and repair methods for the actual material and assembly, including how repaired regions are recoated and verified. Avoid assuming that a solvent suitable for one coating is safe for every component.
If field access is important, address it in the original drawing. A small no-coat region can be valuable when it is intentionally designed and its environmental implications are evaluated.
Prepare a coating quotation package
Provide the assembly files, coating drawing, exact material or allowed selection scope, required thickness basis, cleanliness and cure requirements, quantity and reporting needs. State whether validation trials and repair support are included.
The optional cost worksheet adds your own allowances and does not issue a price. Connect the work to PCB assembly so that testing, coating and shipment requirements are reviewed as one production sequence.
Questions to resolve before the next build
Is UV fluorescence a thickness measurement? It can help show material presence for coatings designed for that inspection route, but intensity alone does not universally establish dry-film thickness or cure. Define the actual verification method and relevant locations with the selected product. Keep coverage, thickness, adhesion and electrical requirements separate so that one convenient observation is not overstated.
Does the volume tool estimate purchased coating? It calculates ideal dry film from the entered area and thickness. Wet material, solids content, transfer efficiency, purge and waste are additional process factors. Measure those on the actual route when estimating consumption. A precise-looking dry-volume result should not be used directly as a purchasing quantity without the missing process information.
Connect the coating drawing to product protection
Treat protection as a complete assembly process. The relevant chain begins with the product environment and continues through material selection, surface condition, application, cure, inspection and service. A strong result at one step cannot compensate automatically for an unresolved interface or an unsuitable surface at another.
Use a controlled drawing to connect design intent to manufacturing. Mark coated regions, no-coat zones, connectors, sensors, mating faces and future test access. Define how edges and difficult geometry are handled. Include the assembly variant and sequence so that an operator does not have to infer whether a component is fitted before or after protection is applied.
Record the exact materials in contact with the process. Coating product, flux residue, cleaning chemistry, labels, adhesives and component surfaces can all matter. Keep technical and safety documentation available for the selected products. A resin-family name or a general compatibility table is a starting point for review, not proof that the complete combination is suitable.
Use representative trials to resolve uncertain geometry and process behavior. Include difficult access, tall components, shadowed regions and relevant no-coat boundaries. A flat coupon may help characterize some aspects, but it may not reproduce the populated assembly's flow, cure or service-access problems. State what each specimen represents.
Define verification in terms of the actual property. Coverage, thickness, cure, adhesion and electrical behavior are distinct. A fluorescent appearance can help show where a suitable material is present, but it should not be used as an unqualified substitute for every other requirement. Match the observation and method to the decision being made.
Consider the life of the product after shipment. Repairs, connector access, calibration and mechanical maintenance may disturb protection. Establish an approved route for any required removal and restoration, and keep the material identity traceable. If a change makes maintenance impractical, resolve the product tradeoff rather than leaving the service team an undocumented problem.
For purchasing, include preparation, masking, material handling, application, cure, inspection and repair assumptions in the scope. Material price alone rarely describes the complete operation. Ask which trials and records are included, and keep environmental qualification separate from routine production checks. A useful enquiry allows the manufacturing team to review the real assembly and explain the proposed route with its limits.
Standards, source context and limits
Use each reference for its stated scope. Equipment and material documentation applies to the identified product and conditions. A published study describes its own specimens and methods; its settings are not universal production limits. Public standard summaries and revision tables do not replace the controlled normative document.
Agree the applicable standards, revisions, product class where relevant, measurement methods and exceptions before production. Distinguish printed-board requirements, assembly workmanship, laboratory competence and finished-product certification. A method name or photograph does not establish that a supplier holds an accreditation or that a particular test is included in an order.
Archive photographs illustrate relevant boards, equipment or operations from the existing RAYPCB website. They are not evidence of current equipment ownership or results from your project. Original diagrams explain concepts and measurement boundaries; they are not inspection records or released manufacturing drawings. Confirm the actual service and reporting scope in the project review.