Melting Point of Solder: Alloy Reference and Temperature Converter

The melting point of solder depends on its alloy composition. Some alloys have a single listed transition temperature; others have a solidus–liquidus range. These material values should not be confused with soldering-iron settings, oven zone temperatures or the measured peak of a production profile.

Use the reference tool to compare selected alloys and convert Celsius to Fahrenheit. The values come from the Kester alloy temperature chart linked below. The table is a focused reference, not a complete catalogue of every solder composition or a recommendation that all listed materials suit your product.

Solder wire spools at a workbench
Solder wire spools at a workbench. RAYPCB site archive image; illustrative context, not a current inspection or ownership record.

Selected values from an identified source

The cited chart lists Sn63Pb37 at 183 °C, Sn60Pb40 at 183–190 °C, Sn96.5Ag3Cu0.5 at 217–220 °C, Sn99.3Cu0.7 at 227 °C and Sn100 at 232 °C. The SAC305 shorthand corresponds here to the listed 96.5/3/0.5 composition. Confirm the actual product specification before applying any value.

The converter preserves a range as a range. A Fahrenheit conversion does not improve the precision of the original measurement or specification. Pure tin is included as a reference material; its presence in the table is not a recommendation to substitute it for an assembly solder.

Reference temperatures are not tool settings
Reference temperatures are not tool settings. Original explanatory drawing; schematic geometry, not released manufacturing data or inspection evidence.

Solder alloy reference and °F converter

RAYPCB ENGINEERING

Solder alloy reference and °F converter

Soldering Process and Defect Prevention
Loading Solder alloy reference and °F converter…
Using this tool & sharing results

Use the stated units, input limits and model assumptions. Results support an engineering discussion; they do not approve a design, process or production order.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

Use the current inputs and keep the assumptions

Choose the question you need to answer before entering numbers. Fields begin blank. Select Load example only to explore the model; example inputs are teaching values, not process recommendations or market prices. The example label remains visible after editing. Reset before preparing a record based entirely on your own data.

Use the displayed units and record the source of every input. Dimensions must share a reference and revision; temperature measurements must identify the location and method. An entered threshold or interval is your supplied review condition, not an IPC limit provided by this website. If a value is unknown, keep it open and obtain evidence rather than filling the space with a familiar number.

Read the assumptions alongside the result. A positive geometric margin answers only the stated calculation. It does not establish wetting, joint strength, production capability or compliance. A negative result remains visible so an incompatible assumption is not hidden. Checklist entries are self-reported and do not prove that the supporting documents were inspected.

Changing an input invalidates the displayed result and disables the download until the calculation is repeated. The text record includes inputs, results and limitations. Processing stays in this browser: no CAD data is read, no measurement system is connected and no information is automatically sent to Contact. Download and attach the record manually if it helps your enquiry. You can contact RAYPCB directly without using a tool.

InputWhat to establish before using it
Review referenceUse a nonconfidential revision/reference.
Kester reference alloyReference values are not tool settings or recommended assembly materials.
Separate temperature to convert · °CYour entered value is converted separately from the sourced alloy range.

Read a range in the right direction

The lower value is the solidus and the upper value is the liquidus for the cited reference. Between them, a non-eutectic alloy can contain solid and liquid phases. A single listed value requires its own phase-transition interpretation rather than an assumption that all heating and cooling happens instantaneously.

See what eutectic solder means for a focused explanation. For the common tin–lead pair, 60/40 versus 63/37 connects the interval to handling and process questions without treating the alloy ratio as a universal quality ranking.

Review itemWhat to establish
ReferenceNamed composition and cited alloy chart.
UnitsCelsius/Fahrenheit conversion retains both range endpoints.
ProcessTool settings and measured assembly profile are separate.
DecisionCombine material limits, thermal history and verification.

An iron setting is a different measurement

A tip temperature describes the tool at its measurement location. Heat transfer into the joint depends on contact area, tip condition, heating capacity, joint mass and the surrounding structure. The joint may remain cooler than the tip while heat flows, and adjacent materials may have separate limits.

Do not select a tip setting by simply adding a fixed number to this table. Use a controlled process developed for the connection. If a joint takes too long to heat, investigate contact and thermal load rather than automatically increasing temperature until the symptom disappears.

Circuit board entering a thermal process
Circuit board entering a thermal process. RAYPCB site archive image; illustrative context, not a current inspection or ownership record.

An oven recipe is also a different measurement

An oven's zone settings and conveyor speed produce an assembly temperature history through a particular heat-transfer system. Different locations on one board can respond differently. The relevant profile is measured on the actual product or an appropriately representative setup, not inferred from the oven display alone.

The profile worksheet calculates peak and time above an entered threshold from sampled data. The thermocouple-planning page explains why measurement location matters. Neither converts one alloy melting value into a complete production recipe.

Measurement worksheet: Solder alloy reference and °F converter
Measurement worksheet: Solder alloy reference and °F converter. Original explanatory drawing; schematic geometry, not released manufacturing data or inspection evidence.

Include every material exposed to heat

Components, laminates, finishes, adhesives, plastics and previously formed joints can constrain the process. A paste's recommended profile must coexist with those restrictions. Moisture sensitivity and repeated exposures also require attention according to the actual materials and handling history.

For a thermally constrained assembly, examine low-temperature paste and its mixed-alloy qualification questions. A lower liquidus can help define an alternative route, but it does not automatically demonstrate adequate service reliability or compatibility with existing solder terminals.

Keep the conversion traceable

The formula is °F = 1.8 × °C + 32. For a range, convert both endpoints independently and retain the composition and source. For example, 183 °C converts to 361.4 °F. Do not round the result to a convenient equipment setting and present it as a recommended process value.

The tool lets you select one of the sourced references or enter a Celsius value for conversion. It reports the selected alloy separately from the entered temperature. This prevents a personal measurement from being silently substituted into the source table.

Use the table to ask better manufacturing questions

When requesting assembly or rework, identify the approved solder system, any existing solder, temperature-sensitive parts, quantity and required inspection. If the alloy is undecided, describe the engineering constraint that drives the choice. A review should connect material data to the actual build sequence.

Use PCB assembly for the commercial build route and PCB soldering for process comparison. The objective is a documented, compatible joining process, not simply the lowest melting point or the highest available tool temperature.

Which number belongs in a production release?

Keep the material reference and the approved process record as separate entries. A release can identify the exact solder product and its supporting data sheet, then reference the measured profile or work instruction used for the assembly. Writing only 217 °C beside SAC305 does not define the required heat history, location or acceptance method. Similarly, a screenshot of an oven setting does not document the temperature reached by the coldest joint. This distinction helps a receiving assembler understand what is fixed, what has been measured and what still requires process development. If a supplier proposes another material, review the material and process consequences together instead of replacing one temperature in a table.

Use material reference data without turning it into a process recipe

Record the exact composition and the source of the temperature data. Alloy shorthand can be useful, but it should not obscure differences in nominal composition, product specification or material already present on a component. Keep the reference value separate from an observation made during a manufacturing operation.

Identify whether a listed temperature is a single transition or a solidus–liquidus interval. Convert units consistently and preserve both endpoints of a range. Extra decimal places produced by a conversion do not imply greater precision than the original source.

Consider the measurement location. A tip, oven zone, package surface and solder joint can have different temperatures at the same moment. Heat-transfer conditions and phase-change energy matter. Therefore the alloy transition cannot be used by itself to set equipment or calculate a safe handling delay.

Examine the full material system before proposing a substitution. Flux, terminal finish, existing solder, board finish and the operating environment can change the decision. A lower transition temperature or a narrower interval does not by itself prove better service reliability, compatibility or regulatory eligibility.

For a trial, define the expected benefit and the evidence needed to evaluate it. If the objective is less thermal exposure, measure the relevant assembly locations. If it is improved handling or wetting, inspect that behavior under the actual process. Avoid claiming that a reference-table comparison completed the qualification.

Provide the approved material identity or the reason a change is being considered with the enquiry. Include the assembly files, temperature-sensitive parts, prior soldering history and required verification. A concise record of assumptions is more useful than a preferred melting-point number without the product conditions that make it relevant.

Evidence review: Melting Point of Solder
Evidence review: Melting Point of Solder. Original explanatory drawing; schematic geometry, not released manufacturing data or inspection evidence.

Standards, source context and limits

Use the references for their stated purpose. A material-vendor application note supports its specified material and conditions; a research paper reports the study it describes. Neither should be converted into a universal setting or a guarantee for a different assembly. Public standard summaries and contents are not complete normative requirements.

Agree the applicable controlled documents, revisions, acceptance basis and exceptions before production. IPC J-STD-001 concerns requirements for soldered assemblies, IPC-A-610 addresses assembly acceptability, and IPC-7711/7721 addresses rework, modification and repair procedures within its scope. Applicability must be established for the contract and task; this page does not certify compliance or reproduce paid acceptance tables.

The photographs are selected from the existing RAYPCB website archive and illustrate relevant materials or operations. They do not establish current equipment ownership, certification or completion of your project. Original diagrams explain concepts and measurement boundaries; they are not inspection evidence or released manufacturing drawings.

From observation to a controlled next step
From observation to a controlled next step. Original explanatory drawing; schematic geometry, not released manufacturing data or inspection evidence.