RAYPCB · ENGINEERING REFERENCE
ENIG Thickness: Nickel, Gold & Measurement
Read nickel and gold as separate requirements. Convert units, inspect a sample set and prepare the measurement basis needed for a useful thickness report.
Original engineering guidance · References checked September 27, 2026
ENIG thickness is a two-layer requirement
Specify and measure the electroless nickel and immersion gold layers separately. The right ENIG thickness is the requirement in the contracted specification and drawing, interpreted with its measurement and acceptance conditions. Do not replace that requirement with a single internet range or a combined nickel-plus-gold number. A combined value can conceal a thin outer layer while the much thicker underlayer dominates the total.
This page helps an engineer read units, evaluate a small set of readings and prepare a clear measurement request. It does not publish an invented universal IPC limit. The IPC-4552B public contents and scope identify separate thickness sections, measurement controls and exceptions; the full authorized document is needed to apply its clauses. Record the exact contracted edition and supplementary requirements before comparing a report with limits.
If your immediate question is finish selection or fabrication scope, start with the ENIG PCB guide. If the concern is how ENIG differs from a contact gold process, use the immersion versus electroplated gold comparison. The worksheet here is for measurement interpretation, not for choosing a finish from thickness alone.
Units that must remain explicit
| Conversion | Exact relationship | Example for unit practice only |
|---|---|---|
| Micrometers to microinches | µin = µm ÷ 0.0254 | 0.050 µm = approximately 1.969 µin |
| Microinches to micrometers | µm = µin × 0.0254 | 2 µin = 0.0508 µm |
| Millimeters to micrometers | µm = mm × 1000 | 0.005 mm = 5 µm |
| Mil to microinch | µin = mil × 1000 | 1 mil = 1000 µin |
These examples demonstrate units, not acceptance values. The difference between a mil and a microinch is a factor of one thousand. A column labelled only “inch” or a copied symbol that loses its micro prefix can therefore create a serious interpretation error. Keep the original report and explicitly label every converted column. Do not round a boundary reading prematurely just to make it look equal to the specified limit.
An example request might refer to a particular nickel interval and a separate gold interval, each in micrometers, with their controlling document references. The numbers should come from that authorized requirement. If the supplier's quotation uses another unit, convert for comparison but preserve the controlling values and stated rounding convention. Conversion does not resolve a disagreement about the underlying measurement method or acceptance rule.

The product photograph shows where finished lands occur on a physical PCB. It cannot establish a coating thickness or prove that a small pad is represented by a nearby large coupon. Use a defined feature map and an appropriate measurement plan. Where the drawing calls for several classes of features, retain their identities instead of averaging all readings into one unexplained “board thickness” value.
XRF readings need a suitable measurement basis
X-ray fluorescence can be used for coating-thickness analysis, but the result depends on the selected layer model, instrument setup and reference materials. The measurement spot must suit the intended feature. A beam sampling both a land and its surrounding mask or substrate is not automatically equivalent to a reading on a sufficiently large, uniform reference pad. Record the feature geometry and measurement location with the data.
Helmut Fischer's coating-thickness measurement overview provides instrument-method context. It is not proof that a particular device, setting or calibration is appropriate for your ENIG lot. Ask the laboratory or fabricator to identify the applicable method, calibration references, deposit model, uncertainty and any limitations on small-feature measurement. A report needs those conditions to be technically interpretable.
Repeated measurements at one point answer a different question from measurements across a panel or across several panels. The former can explore repeatability at that location; the latter also includes spatial or lot variation. Do not combine them without labels and then claim that the resulting standard deviation describes process capability. First decide which engineering question the sampling is intended to answer.
Convert and inspect a thickness sample set
The worksheet accepts one metal layer, one unit, a user-supplied interval, a symmetric measurement uncertainty and two to one hundred readings. It calculates minimum, maximum, mean and sample standard deviation. It also counts values outside the entered interval and uncertainty intervals that cross its boundaries. These are numerical screening results, not a lot disposition or an implementation of a particular IPC sampling rule.
ENIG thickness sample worksheet
The illustrative sample uses gold readings of 0.050, 0.061, 0.058 and 0.064 µm. Their arithmetic mean is 0.05825 µm. The displayed example interval and uncertainty are also illustrative user inputs; they are not presented as IPC requirements. When starting a project, enter your actual requirement and source. Changing the selected metal, unit or reference clears readings and limits to prevent one dataset from being interpreted under another basis.
Sample standard deviation uses the sum of squared differences from the mean divided by n minus one, followed by a square root. That descriptive statistic does not prove normal distribution or adequate sampling. The tool deliberately does not generate Cpk, a supplier score or a passing-lot label from a handful of readings. It gives a reviewable numerical summary with the assumptions still visible in the download.
A boundary reading is not a complete decision
Suppose a measured value equals an entered lower limit. Numerically, it is within an inclusive interval. If a nonzero measurement uncertainty extends below that limit, the interpretation requires the agreed decision rule. The worksheet displays these as different questions: the measured value's position, and whether its symmetric uncertainty interval crosses a boundary. It does not silently turn the uncertainty screen into a contractual rejection rule.
Use the uncertainty supplied for the actual measurement and state its coverage basis in the source field. Entering zero means that uncertainty was not included in this exercise; it does not mean the instrument is perfect. Likewise, a positive margin between every displayed reading and a limit does not demonstrate acceptance of all unmeasured boards. Sampling, measurement capability and the authorized acceptance process remain separate responsibilities.
Do not mix nickel readings with gold readings in one sample list, or mix micrometers and microinches within a run. Avoid combining different feature types without a documented reason. If the goal is to compare locations, run or label them separately in the original report. A larger spreadsheet is not automatically a stronger measurement plan when its rows represent different physical questions.
Thickness does not diagnose every ENIG problem
An acceptable thickness measurement is only one piece of finish evidence. It cannot by itself demonstrate solderability after a specific assembly route, evaluate nickel corrosion morphology or prove bond strength. A surface appearance concern should be investigated using the relevant method and sample. Do not label a board as having a metallurgical defect solely because its measured gold differs from an unsourced number in an article.

Small-pad geometry can make the measurement task different from that on a larger reference feature. The photograph is context for that distinction; it is not an XRF result. Identify whether a report measures the actual feature, an agreed coupon or a representative test area. If the feature is outside the method's qualified scope, ask for a suitable alternative or agreement rather than treating every displayed number as equally reliable.
For a design containing solder lands, bond lands and retained contacts, keep the functions and requirements explicit. A single convenient sampling location may not represent every selective finish zone. If another metal layer is added, such as palladium in ENEPIG, the model and specification change. Use the ENIG / ENEPIG comparison to establish the correct stack before attempting to reuse this two-layer ENIG interpretation.
What a useful measurement report should contain
Begin with the board and lot identifiers, drawing revision, finish stack and governing specification. Identify each measurement feature and its location or map reference. Record instrument identification, relevant calibration or reference basis, measurement model, units and the uncertainty information used for interpretation. Preserve individual readings as well as any summaries so an average cannot conceal a local result that needs review.
The acceptance section should identify who applies the decision rule and which sampling plan governs the lot. A website worksheet should not become an unauthorized substitute for that responsibility. If an exception is agreed, document it with the scope and approvals required by the project. A note such as “customer accepted” without a linked revision or disposition record is difficult to interpret during a later quality investigation.
If two reports disagree, check unit conversion and feature identity first. Then examine calibration, deposit model, spot geometry, repeatability and the sampling distinction. The reports may describe different locations rather than conflicting measurements of one place. Request a coordinated comparison before declaring one supplier wrong. Retain both original records and any subsequent clarification to avoid losing the evidence trail.
Turn an ambiguous requirement into an actionable review
A drawing note says “ENIG, gold 2” and a supplier returns a report in micrometers. The first task is not to decide whether the board passes. Resolve whether “2” means microinches, another unit or an incomplete shorthand, and obtain a controlled drawing clarification. If it means 2 µin, the exact converted value is 0.0508 µm, but that conversion still does not establish whether it is a minimum, nominal or other requirement.
Next, identify the nickel requirement and measurement features. Ask whether the reported readings correspond to the intended sample and whether uncertainty and decision rules have been addressed. Only after those questions are settled can the authorized acceptance process assess the results. This sequence prevents a mathematically correct conversion from becoming a technically unjustified shipment decision.
For assistance with a fabrication request, provide the controlled note, relevant feature map and the question you need answered through Contact. Do not send a spreadsheet average without its units and source context. The online tool can prepare a short review brief, but it does not upload the original report or make a production acceptance decision.
ENIG thickness questions
What is the correct ENIG gold thickness?
Use the applicable contracted specification and drawing, including its measurement conditions and exceptions. This page does not replace that requirement with one universal range. Nickel and gold must be addressed separately.
Is a microinch the same as a mil?
No. One mil equals one thousand microinches. One microinch equals exactly 0.0254 micrometers. Retain units on every value and avoid copying a number without its prefix.
Does a mean within limits prove that the lot passes?
No. Individual results, sampling, measurement capability and the agreed decision rule matter. A mean can conceal outlying values and does not represent every unmeasured feature or board.
Does this tool perform IPC acceptance?
No. It converts units and summarizes user-entered readings against user-entered limits. It does not contain the complete authorized standard, a lot sampling implementation or a corrosion assessment.
Bring the requirement and the drawing together
Send the board revision, construction, quantity and the standard or engineering question you need reviewed. Identify unresolved requirements so the response can address them.
Send requirements for reviewOptional: attach the downloaded worksheet manually. This guidance does not certify a design, approve a shipment or replace the applicable authorized standards.