PCB Manufacturing / PCB drilling and hole planning

RAYPCB · ENGINEERING REFERENCE

PCB Plated Slots: Finished Dimensions, Drawings & Cost

Specify a plated opening that fits the lead and connects the intended copper. Keep finished slot dimensions separate from the fabricator’s machining compensation.

Original engineering guidance · References checked September 28, 2026

Plated slot: define the conductive opening
Finished obround plan view. Copper land is schematic; cutter size and CAM compensation are not specified.

What are PCB plated slots?

PCB plated slots are elongated through openings with conductive metal on their walls. They accommodate blade terminals, connector tabs and other nonround leads while providing the specified connection to surface lands and selected internal copper. The dimensions that matter to assembly are the finished opening after plating, its position and its relationship to the component. An outline that looks correct in the layout editor is not enough to communicate all three.

A plated slot differs from an unplated mechanical cutout. In a plated slot, wall conductivity and the surrounding copper belong to the electrical design. In a mechanical opening, the primary task may be clearance, adjustment or access. If no conductive wall is required, start with the mechanical PCB slot guide instead. Avoid selecting plating simply because a copper land happens to be visible around the opening.

Before requesting manufacture, identify the lead drawing, maximum material dimensions, assembly method and required acceptance conditions. A soldered blade, a press-fit terminal and a screw passing through an elongated hole have different requirements. In particular, do not apply the loose clearance example below to a press-fit connection. Its manufacturer-specified finished hole, plating and insertion conditions require a separate review.

Elongated openings and copper lands on a physical circuit board
Original RAYPCB media: slot shape and surface lands are visible. Finished dimensions and wall plating quality cannot be verified from the photograph.

Specify the opening, not an ambiguous line

For a conventional obround slot, define width W and overall length L, including the two semicircular ends. The nominal radius at each end is W/2, and the distance between the end centers is L − W. These definitions prevent a common drawing mistake: supplying a centerline length as though it were the full opening. A 1.20 × 3.00 mm slot has a nominal end-center distance of 1.80 mm, not 3.00 mm.

This geometry is independent of how CAM ultimately machines the feature. An NC file can describe the finished feature rather than the physical cutter selected by the shop. Ucamco's XNC format specification explicitly defines its tool diameter field in terms of the final hole diameter. Agree the meaning of the actual exported format before applying compensation. Do not enlarge customer data twice by adding a guessed plating allowance in both CAD and CAM.

Drawing itemState explicitlyReason
Slot sizeFinished width and overall length, each with toleranceAssembly sees the final opening
End shapeSemicircular ends or a fully dimensioned special contourA rectangle is not an obround
LocationDatums, center coordinates and orientationCorrect size alone cannot ensure fit
ConductivityPlated through; intended connected copper layersThe opening has an electrical function
AcceptanceApplicable document, class and agreed feature criteriaInspection needs an unambiguous basis
Data authorityDrawing, machine-readable geometry and revision orderConflicts must be resolved before cutting
Finished slot versus blade: width-only example
Illustrative dimensional or document example. Inputs and criteria must be replaced by the approved project records.

Review the lead and the complete tolerance chain

Start with the maximum lead envelope from the component drawing. Measure the relevant width across the slot and the length toward its rounded ends. Compare minimum finished slot dimensions with that envelope, then account for lead pitch, lead position and board feature position. A terminal may enter a single loose slot yet fail when several terminals must enter together. Pattern alignment is therefore a different check from the clearance of one isolated opening.

For an illustrative width check, use a finished width of 1.20 ± 0.10 mm and a maximum blade thickness of 0.90 mm. The minimum opening is 1.10 mm, leaving 0.20 mm total width clearance. That is not 0.20 mm on each side. If perfectly centered, the width-only clearance is 0.10 mm per side before positional and angular effects. The example says nothing about the lead ends, solder flow or the required land.

Rounded ends need particular attention for rectangular terminals. The lead corners approach the curved wall before an equivalent narrow centerline would. Check the complete two-dimensional outline in the component and board drawings. For critical connectors, an assembly fixture or a defined gauge can provide useful evidence, but its acceptance limits must come from the product requirement. A generic online slot calculator cannot supply those limits.

Build a plated-slot drawing note

Enter your approved finished dimensions and allowances, then compare the minimum slot width with the maximum blade thickness. The tool generates a draft note that retains the finished-after-plating definition. It also displays the end radius and end-center distance so the overall-length convention is visible. The result is a review aid, not machine code, a manufacturing release or a full connector fit assessment.

RAYPCB ENGINEERING

Plated slot drawing and width-fit worksheet

Mechanical Features
Loading Plated slot drawing and width-fit worksheet…
Using this tool & sharing results

Use the stated units, input limits and model assumptions. Results support an engineering discussion; they do not approve a design, process or production order.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

The worksheet starts with empty project inputs. Its separately labeled example is only a teaching case. Keep the component and drawing revision in the reference field so a downloaded result remains understandable later. If a dimension or allowance is not known, use the direct enquiry button rather than treating an example as a specification. The Contact page does not receive tool inputs automatically; attach the downloaded text yourself if it is useful.

How a plated slot becomes a conductive feature

The manufacturer must form the opening at a stage that allows its walls to receive the required conductive treatment, then carry the feature through the applicable plating and finishing route. The actual sequence depends on construction, panel handling and the approved process. A plated opening cannot be assumed equivalent to an unplated slot routed through an otherwise finished board. Review that difference before changing the hole designation late in a project.

The wall shape, cleaning and metallization interact. Sharp local irregularities, poor accessibility or unsupported narrow laminate can make a feature harder to process and inspect. The appropriate cutter, machining strategy and compensation belong to manufacturing planning. For the broader sequence, the PCB drilling reference separates feature definition from the shop's drilling and routing decisions. The present page concentrates on the plated elongated opening and its drawing.

Do not derive a wall copper requirement from the visible color of a sample board. A product photograph can show the shape and land arrangement, but not the full wall thickness, continuity or connection to hidden layers. The inspection plan should identify how critical dimensions and conductive integrity will be demonstrated. Agree any special sectioning, electrical test or first-article evidence in the quotation rather than assuming it accompanies every build.

Physical circuit-board panel with copper features and exposed pads
General finished-board context from RAYPCB media. Hidden layer structure, hole-wall quality and mechanical tolerances require traceable inspection records.

Lands, internal layers and electrical clearance

Review the surrounding copper on every relevant layer. A surface annulus that appears generous may coexist with a small internal connection or an unintended plane clearance. Distinguish intentional connections from anti-pads. Check the manufacturing registration assumptions used by the design rules; a nominally centered hole does not describe the worst-case finished relationship between wall and copper.

For a soldered blade, consider the accessible land, solder-mask opening, thermal connection and component body clearance together. A large copper connection can change assembly heat demand, while a small land may not meet the intended joint or robustness requirement. Neither issue is resolved solely by increasing slot width. Coordinate the electrical layout and assembly process using the actual terminal specification.

The slot must also leave an adequate laminate web to nearby holes, cutouts and board edges. Its required width depends on mechanical loading, material construction, handling and agreed fabrication capability. This guide does not assign a universal minimum web or annular ring. Use the selected design rules and contractual acceptance basis, then have marginal features reviewed against the real stackup and panel arrangement.

What changes plated-slot cost?

Cost depends on the number and geometry of slots, how they fit the existing routing and plating route, the surrounding construction and the evidence required. A special inspection request or a tightly controlled terminal fit may be more consequential than a small change in slot length. Compare quotations for the same quantity, board revision, finish, tolerance basis and included tests. A low feature charge is not a complete PCB price.

RAYPCB ENGINEERING

Plated slot scoped quotation worksheet

Mechanical Features
Loading Plated slot scoped quotation worksheet…
Using this tool & sharing results

Budget outputs are planning scenarios. Check the included costs and rate assumptions; a confirmed quotation requires a review of your files and scope.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

This optional worksheet uses rates you enter from a quotation or internal allowance. It calculates quantity × identical features per board × feature rate, adds the stated setup and inspection allowances, and optionally includes a separately entered base-board rate. Incremental-only mode requires that base rate to be zero. The result remains an uncalibrated planning subtotal until the inputs and commercial scope are confirmed; no automatic market rate or yield factor is invented.

Release one coherent slot definition

Export the actual hole and route data, reopen it with the copper layers and compare it with the dimensioned drawing. Verify that the slot exists, has the intended plating declaration and uses the same coordinates and units as the board. If two files both describe the same opening differently, stop and resolve the conflict. A visual line on a mechanical layer should not quietly become an extra routed cut after the plated opening has already been defined.

Turn the feature into a reviewable fabrication record
Original review sequence, not an automatic approval or a certified manufacturing procedure.

Send the fabrication files, board revision, stackup, finished slot table and relevant terminal drawing through Contact. Include quantities and identify the unresolved fit or inspection questions. The general PCB DFM review can examine the surrounding copper and mechanical relationships. Keep a record of any agreed change in both CAD and the released drawing so the next order does not recreate the same ambiguity.

Plated-slot questions

Is slot length measured between the end centers?

Not when the drawing says overall length. For a semicircular-ended slot, end-center distance equals overall length minus width. State the convention directly, including units and tolerances, rather than expecting a supplier to infer it from a screenshot.

Can I calculate the cutting width by adding twice the copper thickness?

That may illustrate an ideal geometry, but it is not a reliable shop instruction. The exported feature meaning, plating distribution and manufacturing compensation must be agreed. Supply finished requirements and let the fabricator define the qualified machining process.

Are plated slots automatically suitable for press-fit terminals?

No. Use the terminal manufacturer's specified opening and plating conditions, together with the approved board construction and assembly requirements. The width-clearance worksheet is deliberately not a press-fit qualification tool.

What should remain in the final inspection record?

Identify the drawing revision, dimensional criteria, plating and electrical requirements, sampling basis and any agreed special evidence. A compliant-looking photograph alone cannot establish those characteristics. Preserve the agreed deviations alongside the original release files.

Review the mechanical feature with RAYPCB

Send the board revision, construction, quantity and the mechanical feature or tolerance question you need reviewed. Identify unresolved requirements so the response can address them.

Send requirements for review

Optional: attach the downloaded worksheet manually. This guidance does not certify a design, approve a shipment or replace the applicable authorized standards.