An FR-4 plated barrel is one part of the heat path
Simplified open-barrel section in an organic laminate. This is not a metal-core isolated-hole drawing.

What thermal vias do inside a PCB

Thermal vias provide conductive paths between copper regions of a PCB. In a common organic-laminate board, plated copper barrels help carry heat from a device's thermal land toward internal or opposite-side copper. They do not make heat disappear; the receiving copper still needs a route to the surrounding air, a chassis or another cooling boundary. A useful thermal-via design therefore combines package information, electrical connectivity, board geometry and the assembly process.

This page focuses on FR-4-style plated-barrel arrays and their layout and assembly tradeoffs. Holes crossing a metal core need a different insulation design; use the multilayer metal-core construction guide for that case. For the overall temperature problem, start with PCB thermal design. The array worksheet below prepares geometry for review and does not claim a universal safe number of vias.

Define the hole, barrel, land and receiving copper

FeatureWhat to recordWhy it matters
Finished holeInside diameter after plating and its toleranceIt is different from the prepared drill diameter
BarrelCopper wall thickness and connected lengthIt contributes to the vertical conduction path
LandOuter copper diameter and fabrication requirementsIt controls more of the local footprint than the hole alone
PitchCentre-to-centre spacingIt affects fit, copper continuity and process access
Receiving layersConnected copper, electrical net and geometryHeat needs a useful destination after passing the barrel
TreatmentOpen, tented, plugged, filled, capped and exact materialsAssembly behavior and the final surface differ

Use the exact package data sheet and relevant attachment guidance as the starting point. The Texas Instruments QFN and SON attachment guide describes exposed-pad attachment considerations and makes clear that the device-specific design matters. Do not transfer one example pitch or via count to every package. A thermal land can be electrically active, so confirm its net before connecting it to a plane or a chassis-related structure.

Routed circuit-board example from the metal-core product library
Existing category reference. Buried layers and hole-wall isolation cannot be verified from this surface photograph.

Plan the array around the package and electrical path

Review the land pattern, signal escape, solder-mask definition and surrounding copper together. Adding a large thermal array can obstruct routing or create an unintended electrical connection. A plane connection should preserve the permitted net and relevant clearances. Where a low-resistance heat path is needed, narrow copper necks or relief patterns can change the result, but changing them also affects soldering and electrical requirements. Resolve that tradeoff in the assembly review rather than using a blanket rule.

The position of vias relative to the thermal pad influences both heat flow and solder deposition. Some package guidance places vias within the land, while other constructions move or treat holes to manage paste loss. The correct choice depends on the package, board and selected process. Coordinate the final via geometry with the PCB stencil design rather than assuming a board-only calculation can approve the solder joint.

Define the land and the edge, not just the hole diameter
Conceptual array. Use the package land pattern and exact fabrication/assembly construction.

Build a geometric array and a barrel-only comparison

RAYPCB ENGINEERING

Thermal Via Array Geometry

Metal Thermal
Loading Thermal Via Array Geometry…
Using this tool & sharing results

Use the stated units, input limits and model assumptions. Results support an engineering discussion; they do not approve a design, process or production order.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

The worksheet fits circular lands within a rectangular pad using the entered centre pitch and clearance from each land edge to the pad edge. It centers the resulting array and draws up to 400 positions. Hole diameter, radial copper wall thickness and land diameter are separate fields. The simple resistance result describes identical copper barrels in parallel under uniform end-temperature assumptions; it excludes fill material and every other part of the thermal path.

The output is useful for a first geometry discussion and for checking that the values describe the same physical object. It is not a CAD layout, annular-ring tolerance analysis, assembly yield forecast or manufacturing approval. Start with a project-specific package and drawing reference. If an assumption changes, regenerate the result before downloading it. The Contact link is always available, whether or not you have completed the model.

Worked example: fit first, then interpret the model

Enter a hypothetical 5 × 5 mm pad, 0.60 mm circular lands, 1.0 mm centre pitch and 0.20 mm minimum land-edge clearance. The model fits five positions in each direction, or 25 vias. The occupied land envelope is 4.6 × 4.6 mm, leaving the entered 0.2 mm clearance on every side when centered. These are illustrative values, not a recommended package pattern. A real land pattern may have different paste, routing or electrical restrictions.

With a 0.30 mm finished hole and 0.025 mm radial plating, the outside barrel diameter is 0.35 mm. The annular copper cross-section is approximately 0.02553 mm². For a 1.6 mm barrel and an illustrative copper conductivity of 400 W/(m·K), one idealized barrel contributes about 156.7 K/W. Twenty-five identical barrels in parallel give about 6.27 K/W for the barrels alone. This is not the board's junction-to-ambient thermal resistance.

The apparent high single-barrel value explains why multiple paths can matter, but it does not mean that adding vias keeps reducing complete-system resistance in direct proportion. Shared spreading, attachment, receiving copper and cooling become limiting terms. Adding vias also changes the solderable surface and fabrication scope. The useful question is which part of the path remains dominant, not how many circles can be drawn under the package.

Open, tented, filled and capped are different constructions

An open plated hole can provide a path for solder to move during assembly. Tenting covers an opening with solder mask under a specified process, while plugging or filling addresses the hole differently. A filled and copper-capped via adds a defined filled volume and a metal surface over it. These descriptions should not be used interchangeably on the fabrication drawing. State which holes receive the treatment and the relevant acceptance requirements.

Coordinate the barrel, fill, cap and paste
Via treatments are distinct. Resin, conductive paste and solid copper fill are not interchangeable.

Resin, conductive paste and solid copper fill have different properties. A trade name containing “copper” does not establish the same conductivity as a solid copper cylinder. The worksheet deliberately ignores fill conduction rather than silently selecting a favorable property. If fill contributes materially to your thermal analysis, obtain the exact material and process data and build a model that represents the real section, including interfaces and any voids relevant to the analysis.

For via-in-pad structures, surface flatness, cap condition and the assembly process can be as important as a material number. The via-in-pad guide is the related manufacturing topic. Keep a separate record of which vias are intentionally in solderable pads and how their treatment appears in fabrication data. A global note that says only “all thermal vias filled” can remain ambiguous if the file set does not identify the hole group.

Paste, reflow and inspection belong in the same review

An exposed-pad joint needs appropriate deposition, placement and reflow conditions. Paste volume, aperture arrangement and via treatment can interact. More paste does not automatically compensate for an open-hole design, and one void percentage should not be presented as the universal acceptance limit for every package or application. Use the agreed package guidance and product requirements, then verify the selected assembly process and inspection method.

An X-ray inspection review can help define how hidden solder features will be assessed. It does not directly measure operating junction temperature, and a visually acceptable joint does not alone establish the full heat path. Combine the relevant inspection evidence with thermal measurements under defined operating conditions. Record the board revision, via treatment, stencil and assembly process so that a result can be reproduced.

LED circuit with visible copper back
Product reference. Electrical isolation and the thermal-pad connection require a section drawing.

The second product image provides a contrasting metal-base construction, not proof of an FR-4 via array. That distinction is intentional: a design using a solid base and isolated circuitry should not inherit the ordinary plated-barrel model. The photograph cannot reveal the package contact, internal dielectric or tested performance. Use the section drawing to decide which model describes the proposed board before comparing calculated results.

Turn the sketch into a controlled release

Agree prepared drill and finished hole requirements, plating expectations, lands, process tolerances and hole treatment with the manufacturer. The nominal land covering the nominal barrel is not an annular-ring acceptance check. Registration and dimensional allowances can change the minimum remaining copper. Review the relevant PCB drilling requirements and make sure that the fabrication notes distinguish electrical vias from component holes.

The complete file set should identify layer connections, receiving copper, hole groups, mask openings and fill/cap requirements. Where a package application note differs from the initial fabrication proposal, record the resolved choice. Avoid a manufacturing edit that silently changes the thermal land or an assembly edit that changes the thermal model without updating the drawing. Design, fabrication and assembly should review the same revision.

Verify the result at the actual thermal boundary

Measure actual dissipated power and identify the temperature point being observed. Keep airflow, enclosure, mounting and the external cooling interface representative of the application. A bare bench board can behave differently from the same board installed in a product. Neighboring heat sources and duty cycles can also change the local boundary. Record these conditions alongside the readings instead of comparing temperatures from unrelated setups.

Use the result to refine the system model and identify whether more vias, more copper, a better interface or another architecture is the next useful change. A larger via count is not a success metric by itself. If a board redesign is needed, send the thermal land, stackup, loss estimate and process requirements through a PCB manufacturing review. The array brief is optional supporting information, not a substitute for fabrication and assembly files.

Thermal-via design questions

Is there one correct diameter and pitch for thermal vias?

No. Package geometry, fabrication capability, electrical connections and assembly method control the choice. Example values from another design are a starting point for review, not a universal release rule.

Does the calculated resistance predict the device temperature?

No. It includes only the idealized copper barrels. Solder, spreading, receiving layers, fill, package and external cooling are omitted, so the result cannot be used alone as a junction-to-ambient value.

Does a tented via equal a filled and capped via?

No. The hole volume and final surface can be different. Specify the exact treatment and acceptance scope rather than relying on an ambiguous shorthand.

Can I copy this array into a metal-core board?

Not without a separate construction review. A conductive metal core changes isolation and interconnection requirements. The ordinary organic-laminate barrel model does not describe that insulated-hole structure.

Bring the requirement and the drawing together

Send the board revision, construction, quantity and the standard or engineering question you need reviewed. Identify unresolved requirements so the response can address them.

Send requirements for review

Optional: attach the downloaded worksheet manually. This guidance does not certify a design, approve a shipment or replace the applicable authorized standards.