A layout review organized around the transition
| Location | Show in the design | What the reviewer checks |
|---|---|---|
| Rigid region | Component lands, mounting features, hole spans and copper layer assignment | Whether the rigid construction supports assembly and connects to the intended flex layers. |
| Rigid-to-flex boundary | Dimensioned boundary, coverlay termination and a controlled keepout | Registration and mechanical stress are considered together; a generic clearance is not a qualified rule. |
| Bend zone | Bend direction, conductor direction, width changes and any vias | Avoid abrupt conductor changes in the moving span; review any unavoidable feature individually. |
| Connector tongue | Exposed side, copper finish, finished thickness and local stiffener | Connector drawing and total local thickness agree; the stiffener is not treated as a copper layer. |
| Return path | Reference copper through the flex and transitions | The signal has a defined electrical return; plane changes require an electrical review. |
Select the flexible base film, copper type, adhesive system and coverlay together. A lower-loss dielectric does not by itself establish bend endurance; a mechanically thin section does not by itself provide the required impedance.
Worked review scenario: a six-layer rigid board routes a controlled-impedance signal on L1, but only L3–L4 continue through its flex. First relocate or transition that route in the rigid section, then define its reference conductor across the flex. Recalculate the electrical geometry for the covered flex construction instead of carrying over the L1 microstrip width. Review the via and transition discontinuity separately.
Use the stackup example for layer continuity, and the capability review for the project-specific manufacturing limits.
Region and bend workbench
Use consistent layer numbering and actual finished thicknesses. The calculator checks one contiguous flex span; it does not infer bonding materials or approve a manufacturing process.
Rigid-Flex Region & Bend Workbench
Optional transmission-line estimate
For an initial homogeneous-line comparison, use this shared engineering model. Covered flex and transitions need a more complete electrical model.
Open the preliminary line calculator
Rigid-Flex Preliminary Transmission-Line Planner
Continue with the next engineering decision
Preparing the CAD handoff? Compare KiCad and Altium rigid-flex release requirements for region definitions, bend drawings and manufacturing outputs. The released files must describe the intended construction regardless of the CAD editor.
Once the rigid-flex construction is defined, review the broader PCB manufacturing and production-release scope to align fabrication data, inspection and the supply request.
Reference documentation
Use the documentation for your installed software version and the selected material grades. Altium rigid-flex design documentation describes its region and bending workflow. These references support design communication; they are not manufacturing approval for a particular board.
Send a complete project brief
Include the flat outline and installed view, layer/region mapping, material grades, finished thicknesses, bend duty, copper artwork, drill information and quantities. Add the BOM, placement file and acceptance requirements when assembly is included.
Mark unresolved choices rather than guessing. Download tool results if they help describe your request. Contact does not automatically receive calculator inputs.