PCB Failure Analysis: Preserve Evidence and Test the Mechanism
PCB failure analysis investigates why a board or assembly lost the required function. The observed symptom, physical failure mode and underlying cause are different parts of the explanation. A burnt component may be the consequence of another fault; an intermittent connection may disappear when the board is handled or reheated.
This page describes an evidence-preserving workflow. The tool helps organize observations, samples and next actions. It does not diagnose an unseen board or assign a root cause from a selected symptom.

Preserve the original condition
Record the product identity, revision, service conditions, symptom and first observation. Photograph the relevant areas and retain logs, packaging and affected parts where useful. Avoid cleaning, reheating or replacing components before deciding what evidence those actions could remove.
Make the assembly safe through qualified procedures without unnecessary disturbance. If destructive work is needed, agree the specimen and sequence first. Keep suitable comparison samples when available.
Separate symptom, location and mechanism
No communication is a symptom. An open connection at a particular interface is a located failure. Fatigue, corrosion, contamination or manufacturing damage are possible mechanisms that need supporting evidence. Do not skip from the first symptom directly to a preferred cause.
The component-testing guide and solder-short guide support electrical localization. Their results should be interpreted with the schematic and measurement conditions.
| Review item | What to establish |
|---|---|
| Preserve | Retain identity, original condition and history. |
| Localize | Separate symptom, failed interface and mechanism. |
| Discriminate | Use methods that distinguish plausible causes. |
| Verify | Test the corrective action and record remaining uncertainty. |
Begin with methods that preserve options
Visual examination, suitable electrical measurements and relevant imaging can narrow the location before destructive preparation. Choose the method according to the question rather than running every available test. Record what each result rules in or leaves unresolved.
For hidden package connections, BGA inspection explains the imaging and electrical boundaries. A regular X-ray appearance does not eliminate every possible interface defect.

Plan destructive analysis deliberately
Cross-sectioning, material analysis or other specialist methods can provide valuable evidence but may consume the sample. Identify the location, orientation and expected observation before preparation. An incorrectly placed cut can miss the feature and remove the opportunity for another method.
Use a laboratory with suitable scope and reporting. The laboratory-evaluation guide helps specify specimen handling, method and report detail without assuming that equipment ownership proves competence.
Failure-analysis evidence brief
Failure-analysis evidence brief
Use the current inputs and keep the assumptions
Choose the engineering question before entering numbers. Fields begin blank. Load example fills teaching values so you can understand the model; those values are not recommended dimensions, process settings or market prices. The example label remains visible after edits. Reset before preparing a record based entirely on your own project data.
Use the displayed units and keep a reference for each input. Counts must describe the same scope, and measurements must share the declared conditions. A threshold entered by you remains your supplied review condition. The website does not turn it into an IPC limit or an approved product requirement. If the necessary value is unknown, obtain the evidence rather than replacing it with an attractive assumption.
Read the result and its limitations together. An access fraction is not fault coverage, a cost allowance is not a quotation, and a completed evidence checklist is not a safety or quality approval. Negative margins remain visible where the model permits them. They identify a conflict in the entered scenario rather than silently adjusting the result.
Changing an input invalidates the result and disables its download until you run the tool again. The text record contains the inputs, result and limitations. Processing stays in your browser; no CAD files, instruments or certificates are read. No data is automatically transferred to the enquiry form. Download and attach the record manually if useful, or contact RAYPCB directly without completing the tool.
| Input | What to establish before using it |
|---|---|
| Review reference | Use a nonconfidential revision or scope reference. |
| Specimen identity and service history | Self-reported status; retain the actual evidence or N/A rationale. |
| Original condition preserved | Self-reported status; retain the actual evidence or N/A rationale. |
| Mechanism and alternative explanations | Self-reported status; retain the actual evidence or N/A rationale. |
| Evidence-preserving method sequence | Self-reported status; retain the actual evidence or N/A rationale. |
| Corrective-action verification plan | Self-reported status; retain the actual evidence or N/A rationale. |
| Next action / record reference | Use a nonconfidential reference; this tool does not verify the record. |
Test competing explanations
Compare the observations with plausible alternatives. Ask what additional evidence would distinguish a process defect from overstress in service, or a material issue from mechanical handling. Preserve uncertainty when the sample or history cannot resolve it.
A useful conclusion states the supported mechanism, evidence, limitations and any remaining alternatives. It should not be more certain than the available observations.
Verify corrective action against the mechanism
Replacing the failed component may restore function without preventing recurrence. The corrective action should address the demonstrated cause and include an appropriate verification. Keep changed variables identifiable and update the controlled design or process documents.
Use the PCB reliability-improvement guide to connect the remedy to service conditions. A small successful trial can support the next decision but should not be presented as a universal lifetime guarantee.
Submit an investigation request with a clear decision goal
Provide the failure history, affected and unaffected samples if available, schematic, construction, service conditions and prior interventions. State whether the decision concerns containment, repair, supplier disposition or a design change.
Ask RAYPCB to review the manufacturing-related evidence and requested scope. Keep production release and root-cause closure separate: a replacement batch may be needed before the full mechanism is established, but that operational decision should not erase the open investigation.
Questions to resolve before the next build
Does visible burning identify the root cause? It locates damage but may not show the initiating fault. An overstressed component can be the consequence of another connection, control or supply problem. Preserve surrounding evidence and service history, then test explanations systematically. A dramatic photograph should not make the conclusion more certain than the investigation supports.
What if only one failed sample exists? Plan the sequence carefully and agree which methods can consume or alter it. Document limitations and preserve intermediate observations. A single sample can provide valuable evidence, but it may not establish prevalence or explain every reported symptom. State what the analysis supports and what remains unresolved instead of inventing statistical confidence.
Preserve evidence while narrowing the cause
Make the investigation reproducible before making it broader. Record the exact symptom, product revision, conditions and observations already made. Identify which statements are measured, which are reported by the customer and which are hypotheses. This prevents an early guess from becoming the accepted explanation without supporting evidence.
Preserve the specimen's value. Cleaning, probing, powering, flexing, reheating and component removal can change the condition being investigated. Plan those actions under qualified procedures and document interventions. Where possible, retain an unaltered sample and a suitable comparison unit so that later methods still have meaningful evidence to examine.
Use the schematic and construction to interpret readings. Parallel paths, active devices, stored charge and the measurement interface can affect an observation. A familiar meter indication is not enough to identify a failed component. State the electrical path, instrument mode, reference and board state so another reviewer can understand the result.
Choose the next method to distinguish explanations. If two plausible mechanisms predict the same observation, repeating that observation may add little. Ask what evidence would separate them and whether obtaining it would destroy information needed for another method. This keeps the investigation purposeful rather than turning it into a checklist of every available laboratory technique.
Contain the operational problem while preserving technical uncertainty. Production may need a hold, additional screening or replacement material before the root cause is fully established. Record the basis and limits of that containment separately. A temporary action that restores operation does not automatically prove the cause or prevent recurrence.
Verify the remedy against the supported mechanism. A repaired board that passes one check may still require additional inspection or testing after the intervention. Update the relevant design, supplier requirement or process control when the cause is confirmed. Keep the original failure and repair history visible instead of replacing it with a final pass flag.
Prepare the enquiry around the decision needed. State whether the goal is identifying a defect, choosing a repair, evaluating a lot or preventing recurrence. Include the evidence already available and the sample constraints. RAYPCB can then review the manufacturing-related scope while specialist analysis, product safety decisions or unresolved design requirements remain clearly assigned.
Standards, source context and limits
Use each reference for its stated scope. Equipment and material documentation applies to the identified product and conditions. A published study describes its own specimens and methods; its settings are not universal production limits. Public standard summaries and revision tables do not replace the controlled normative document.
Agree the applicable standards, revisions, product class where relevant, measurement methods and exceptions before production. Distinguish printed-board requirements, assembly workmanship, laboratory competence and finished-product certification. A method name or photograph does not establish that a supplier holds an accreditation or that a particular test is included in an order.
Archive photographs illustrate relevant boards, equipment or operations from the existing RAYPCB website. They are not evidence of current equipment ownership or results from your project. Original diagrams explain concepts and measurement boundaries; they are not inspection records or released manufacturing drawings. Confirm the actual service and reporting scope in the project review.